Welcome Customer !

Membership

Help

Shanghai Qiyi Instrument Equipment Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Shanghai Qiyi Instrument Equipment Co., Ltd

  • E-mail

    Ellasong@qiyi-china.com

  • Phone

    13296018069

  • Address

    Room A226, Building A, No. 58 Yindu West Road, Shanghai

Contact Now

Headspace residual oxygen analyzer

NegotiableUpdate on 02/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

OXY-TOUCHS headspace residual oxygen analyzer, also known as optical oxygen pressure multifunctional analyzer, is a high-precision pressure detection instrument with automatic temperature, pressure, and salinity testing and compensation functions to ensure long-term stability of equipment operation.

Product Details

Product Name: OXY-TOUCHS Optical Oxygen Pressure Multi functional Analyzer

Product Introduction: OXY Touchs equipment has automatic testing and compensation functions for temperature, pressure, and salinity, ensuring long-term stability of equipment operation. It is a high-precision pressure detection instrument. The equipment is widely used for headspace dissolved oxygen and pressure testing in pharmaceutical packaging; Applications in industries such as biological fermentation, medical devices, scientific research analysis, and environmental protection. The sensor adopts a 0.7mm solid probe and optical patch type to avoid sealing effects during the testing process and for non-destructive sample retention testing purposes. Adopting a desktop integrated design, it can be used with a touch screen, connected to a printer for real-time printing, supports online continuous measurement, has a high degree of software automation, and has raw data storage and three-level permissions for audit tracking. PreSens optical sensors have fast and accurate testing capabilities, with a headspace oxygen response time of<3S T90; Dissolved oxygen response time<30 seconds T90, pressure response time<3 seconds can quickly complete sample testing.

Headspace residual oxygen analyzerProduct Features:

1. Simultaneous detection of oxygen and pressure

2. Convenient to move, can sterilize and connect to a printer for real-time printing

3. Fast testing rate using fluorescence quenching principle

4. The drug headspace only needs to meet 0.1ml to be stable and high without daily calibration

5. The appearance adopts an integrated design, and the host adopts touch screen operation

6. The software meets the data integrity requirements of 21CFR Part 11


Application scope:

1. Dissolved oxygen, gaseous oxygen analysis, nitrogen filling process validation, etc. in the field of biopharmaceutical technology

顶空残氧仪

2. Oxygen analysis testing and monitoring in the field of water quality analysis and soil environment research

顶空残氧仪

3. Monitoring of Oxygen Content in Life Science Cell Culture Process

顶空残氧仪


4. Monitoring and testing of oxygen content in packaging for the food and beverage industry

顶空残氧仪

In the field of biopharmaceutical technology, dissolved oxygen, gaseous oxygen analysis, nitrogen filling process validation, etc.

Headspace residual oxygen analyzerTechnical parameters:


Oxygen O ₂

pressure

Specifications

Gaseous oxygen dissolved oxygen

pressure

measurement range

0-100% oxygen 0-45mg/L

0-1000hPa 0-1400μmolL

0-103Kpa absolute pressure

detection limit

0.03% oxygen 15ppb

0.05Kpa

Sampling quantity

Oxygen: ≥ 0.1ml; Dissolved oxygen: please inquire for details

N/A

resolution

Under 1% oxygen conditions: ± 0.01% oxygen under 0.4mg/L conditions: ± 0.005mg/L under 20.9% oxygen conditions: ± 0.05% oxygen under 9.0mg/L conditions: ± 0.025mg/L

0.001Kpa

precision

± 0.05% or 3% reading, take the larger value

<1Kpa±0.2Kpa >1Kpa±0.1Kpa

Temperature measurement range

0 ℃ to 50 ℃


Corresponding time (too)

Oxygen<6sec Dissolved oxygen<40sec

<3sec

Temperature measurement range

0 ℃ to+50 ℃

N/A

Compatible media

Water solution, ethanol, methanol

N/A

No cross sensitivity

pH1-14、 Carbon dioxide, hydrogen sulfide, sulfur dioxide, ion types

N/A

sterilization step

Steam sterilization *, ethylene oxide (Eto), gamma irradiation

one

Cleaning steps

In situ cleaning (CP2% sodium hydroxide 80 ℃, 176 F'3% hydrogen peroxide, acidic agents (hydrochloric acid, sulfuric acid) up to 4-5%

No need to clean