High voltage pinhole leak detection machine

NegotiableUpdate on 01/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The HDA-1 glass ampoule electronic micro hole leak detector manufactured by Haimen Jinjing Pharmaceutical Machinery Co., Ltd. has the characteristics of stable performance, good detection data, high leak detection accuracy, easy operation, and convenient cleaning and maintenance, and has been recognized by many customers.
Product Details
High voltage pinhole leak detection machine

1. Purpose and model of leak detection machine

HDA-1 glass ampoule electronic micro hole leak detector is used for glass ampoule small water needle injection products.

2. Material

The design and manufacturing of leak detection machines meet the requirements of China's 2010 version of GMP. The contact part of the product is made of 304 stainless steel, nylon, and polypropylene resin materials. The internal rack is made of high-quality A3 steel plate, angle steel and coated. The exterior is made of stainless steel 304.

3. Function and action process

The HDA-1 glass ampoule electronic microporous leak detector is a machine that performs non-destructive inspection on sealed glass ampoule products filled with liquid medicine by applying high frequency and high pressure. Products with leakage points are automatically removed.

The injection product is vertically transmitted to the bottle feeding belt conveyor, and then transferred to the detection disk through the bottle feeding tray. After the ampoule is in a horizontal rotating state, it undergoes alternating inspections of the entire ampoule body through CH1, CH2, CH3, and CH4 high-voltage electrodes. Unqualified products enter the unqualified product collection room through the * separation tray, and qualified products are discharged into the qualified product collection room through the second separation tray and sent to the next process.

High voltage pinhole leak detection machine

4. Safety performance

The HDA-1 glass ampoule electronic microporous leak detector is equipped with fault detection and sound and light alarm devices.

4.2 The equipment shall be affixed with a unified instruction nameplate.

4.3 The moving parts of the equipment that are prone to causing harm to operators are equipped with safety covers, and the electrical control cabinet is equipped with safety locks that meet the zero entry standard.

The 4.4HDA-1 glass ampoule electronic micro hole leak detector equipment is equipped with a protective isolation door at the high voltage discharge point. When the door is opened, the machine automatically stops, the high voltage is turned off, the signal generator is activated, and an alarm is triggered.

4.5 Any part of the equipment is easy to clean.

4.6 Install emergency stop switches in areas easily accessible to operators.

When the power is cut off, the machine gradually stops to protect the safety of operators, equipment, and products.

4.8 After restoring power supply, the leak detector must be manually started.

4.9 Equipped with independent ozone decomposition catalyst and exhaust fan

4.10 The safety performance of the electrical system complies with the corresponding national standards.

4.11 Safety performance meets relevant safety standards.

4.12 Warning labels shall be affixed in appropriate locations.

4.13 The equipment has reliable protective grounding. The insulation resistance and withstand voltage meet the relevant requirements.

4.14 Install and hang safety signs on the electrical cabinet.