BS-2100 typeClosed flash point tester
This instrument complies with the requirements of the national standards GB/T 261-2008 for the determination of flash point using the Binsky Martin closed cup method and SH/T0315. It is controlled by microcomputer technology and equipped with a large screen LCD display and a micro printer. It has the characteristics of high measurement accuracy, good repeatability, stable and reliable performance, and simple operation.
This instrument complies with the requirements of the national standards GB/T 261-2008 for the determination of flash point using the Binsky Martin closed cup method and SH/T0315. It is controlled by microcomputer technology and equipped with a large screen LCD display and a micro printer. It has the characteristics of high measurement accuracy, good repeatability, stable and reliable performance, and simple operation.
BS-2100 typeClosed flash point tester
Advantages and Characteristics
*Chinese LCD screen display, menu oriented input;
*Adopting high-speed signal processor control and high-precision analog/digital conversion circuit;
*Adopting adaptive PID control algorithm to automatically adjust the heating curve according to standard requirements;
*The entire testing process includes automatic detection, lid opening, ignition, alarm, cooling, printing, etc;
*Data storage function, capable of storing 200 results and allowing for easy access to historical records at any time;
*Differential detection, automatic correction of system deviation, automatic stop detection and alarm for temperature exceeding the limit;
*Automatic completion of air supply, stirring, ignition, detection, alarm, cooling, and printing instruments;
BS-2100 typeClosed flash point tester
Technical Parameter
Display mode: |
Chinese LCD display |
Measurement method: |
Thermocouple differential detection formula |
Measurement range: |
Room temperature -350 ℃ |
Resolution: |
0.1℃ |
Repeatability: |
National standard: allowable deviation of ± 1 ℃ when flash point value<104 ℃, allowable deviation of ± 2 ℃ when flash point value ≥ 104 ℃ International standard: allowable deviation of ± 1 ℃ for flash point value ≤ 110 ℃, allowable deviation of ± 2 ℃ for flash point value>110 ℃ |
Printer: |
Thermal printer, 56mm paper width |
Temperature detection: |
Imported platinum resistor (Pt100 Ω) |
Ignition method: |
Electronic ignition with gas source |
Self checking function: |
Automatic diagnosis of instrument faults |
Cooling method: |
Forced air cooling |
Power consumption: |
<550W |
Usage environment: |
Temperature 10 ℃ -45 ℃, humidity 30-80% |
Power supply: |
AC220V±10% |
External dimensions: |
397*305*240mm |
Weight: |
About 15 kilograms |