BS-3000 typeClosed flash point tester
This instrument complies with the requirements of the national standards GB/T 261-2008 for the determination of flash point using the Binsky Martin closed cup method and SH/T0315. It is controlled by microcomputer technology, does not require automatic electronic ignition from a gas source, and has a self checking function when turned on. It has the characteristics of high measurement accuracy, good repeatability, stable and reliable performance, and simple operation; It is an ideal instrument for conducting closed flash point testing in departments such as petroleum, chemical, power, environmental protection, railway, and scientific research.
BS-3000 typeClosed flash point tester
Advantages and Characteristics
Color Chinese touch screen display, Chinese human-machine dialogue display interface, menu oriented input;
Adopting high-speed signal processor control and high-precision analog/digital conversion circuit;
Adopting adaptive PID control algorithm to automatically adjust the heating curve according to standard requirements;
The entire testing process includes automatic detection, lid opening, ignition, alarm, cooling, printing, etc;
Safe ignition method for non gas source platinum alloy electric heating wire, stable and reliable, with high testing accuracy;
Built in atmospheric pressure automatic detection chip, automatic measurement, calibration, and automatic correction of atmospheric pressure flash point value;
● Powerful data storage function, capable of storing 300 results;
Differential detection, automatic correction of system deviation, automatic stop detection and alarm for temperature exceeding the limit;
BS-3000 typeClosed flash point tester
Technical Parameter
Display mode: |
Chinese touch screen display |
Measurement method: |
Thermocouple differential detection formula |
Measurement range: |
Room temperature -350 ℃ |
Resolution: |
0.1℃ |
Repeatability: |
National standard: allowable deviation of ± 1 ℃ when flash point value<104 ℃, allowable deviation of ± 2 ℃ when flash point value ≥ 104 ℃ International standard: allowable deviation of ± 1 ℃ for flash point value ≤ 110 ℃, allowable deviation of ± 2 ℃ for flash point value>110 ℃ |
Printer: |
High speed thermal printer, 56mm paper width |
Temperature detection: |
Imported platinum resistor (Pt100 Ω) |
Ignition method: |
No gas source electronic ignition |
Self checking function: |
Automatic diagnosis of instrument faults |
Cooling method: |
Forced air cooling |
Power consumption: |
<550W |
Usage environment: |
Temperature 10 ℃ -45 ℃, humidity 30-80% |
Power supply: |
AC220V±10% |
External dimensions: |