MLSS700 sludge concentration meter

NegotiableUpdate on 04/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Zhongyi Baikong Instrument Co., Ltd. focuses on the practice of automation control technology and has provided reliable detection instruments for online analysis, level, flow, pressure and other aspects of liquids for many years.

Product Details






Zhongyi Baikong Instrument Co., Ltd. focuses on the practice of automation control technology and has provided reliable detection instruments for online analysis, level, flow, pressure and other aspects of liquids for many years.

A complete sludge concentration measurement system includes a concentration transmitter, concentration electrodes, and electrode mounting brackets.
The SS570 Chinese turbidity meter is a brand new sludge concentration analyzer. This meter is a highly intelligent continuous monitoring instrument with a color screen display. The concentration transmitter can output analog signals of 4-20mA, upper and lower limit alarm control signals, digital signals, and display parameters such as temperature, sludge concentration, time, and status. Sludge concentration meter is a large-scale turbidity meter mainly used to measure the concentration value of sludge in sewage treatment plants, achieving the purpose of control. It can be widely used for continuous measurement of turbidity in various water quality industries such as power, chemical, environmental protection, medicine, and food.


The infrared light emitted by the transmitter on the sludge concentration meter sensor is absorbed, reflected, and scattered by the measured substance during transmission, and only a small portion of the light can reach the detector. The transmittance of the transmitted light is related to the concentration of the measured sewage, so the concentration of the sewage can be calculated by measuring the transmittance of the transmitted light.

Sensor of sludge concentration meterAdopting dual beam infrared scattering spectrophotometer detection technologyThe light emitted by each transmitter is transmitted and directed onto two detectors, creating a series of optical paths and obtaining a data matrix. By analyzing these data signals, the accurate concentration of suspended solids in the medium can be obtained, and interference can be effectively eliminated to compensate for deviations caused by pollution, enabling the instrument to operate in harsh environments.





The instrument should be installed indoors or in a location with protective devices, and flammable and explosive materials should not be placed around it. The installation location of the instrument should be chosen in a place that is easy for users and installation and maintenance personnel to read the instrument nameplate, and is convenient for use, maintenance, and repair.
All power and pipeline connections must comply with national and local standards. The front end of the instrument power supply must be equipped with an insulation switch or a circuit breaker.
For safety and to avoid interference from external signals on the instrument, the power cord of the instrument should be connected to a socket with corresponding specifications, ground wire markings, and electrical standards, and the ground wire must be well grounded.
The internal circuit of the instrument can be found in the wiring diagram, and the rated values of voltage and power can be found on the nameplate of the product. The user's power supply capacity must meet the requirements for normal use of the instrument.
1) Precautions for transmitter installation
Avoid direct sunlight and vibration of the transmitter;
The transmitter should be installed slightly above the operator's head up position for easy viewing of the panel or control operations; Leave sufficient space for the opening and maintenance of the transmitter enclosure.
2) Precautions for sensor installation
Install sensors at appropriate locations in the process to ensure representative measurement results are obtained.
Install the sensor in an easily accessible location for regular cleaning and maintenance.
Sensors should be avoided from being installed in locations where bubbles accumulate to prevent interference signals.
Install the sensor near a representative and well mixed sampling point, with a recommended maximum distance of no more than 1.5 meters (5 feet) between the sensor and the sampling point.
It is necessary to compare the readings of laboratory analyzers and instruments during calibration and normal use.