Welcome Customer !

Membership

Help

Shijiazhuang Aerospace Automation Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Shijiazhuang Aerospace Automation Technology Co., Ltd

  • E-mail

    sjzhangtian@163.com

  • Phone

    137-2278-0778

  • Address

    12-1-502 Rongguo Garden, No. 528 Zhongshan East Road, Chang'an District, Shijiazhuang City

Contact Now

NHR-5600 series flow integrator controller

NegotiableUpdate on 08/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Overview: The NHR-5600 series flow integrator controller is designed to collect, display, control, remotely transmit, communicate, print, and process various signals such as temperature, pressure, and flow on site, forming a digital acquisition system and control system. It is suitable for flow integrator measurement and control of liquids, general gases, superheated steam, saturated steam, etc. instrument panel 160*80mm(A Type 80 * 160mm (Type B) 96 * 96mm (Type C) 96 * 48mm (Type D) Parameter Function Note: The above parameters are all instrument parameters .....

Product Details

overview

The NHR-5600 series flow integrator controller is designed to collect, display, control, remotely transmit, communicate, print and process various signals such as temperature, pressure, and flow on site, forming a digital acquisition system and control system. It is suitable for flow integrator measurement and control of liquids, general gases, superheated steam, saturated steam, etc.

instrument panel
160 * 80mm (Type A) 80 * 160mm (Type B) 96 * 96mm (Type C) 96 * 48mm (D-type)
Parameter function
Note: The above parameters are all parameters of the instrument. If it is not a fully functional instrument, the parameters corresponding to the unselected function will not be displayed.
Instrument wiring diagram
The specifications and dimensions are A, B, and C type wiring diagrams
Note: The direction of the wiring terminals on the back cover of the horizontal and vertical instruments is different, as shown in schematic diagram 1.

Figure 1
instrument selection
NHR-5600□-□/□/□-□/□/□/□/□( )-□-( )
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑾
① Specification and size
code Width * Height * Depth code Dividing number (measurement range)
A
B
C
D
160 * 80 * 110mm (horizontal)
80 * 160 * 110mm (vertical)
96 * 96 * 110mm (Method)
96 * 48 * 110mm (horizontal)
X
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
55
56
NO INPUT SIGNAL
Thermocouple B (400-1800 ℃)
Thermocouple S (0-1600 ℃)
Thermocouple K (0-1300 ℃)
Thermocouple E division (0-1000 ℃)
Thermocouple T division (-200.0-400.0 ℃)
Thermocouple J division (0-1200 ℃)
Thermocouple R scale (0-1600 ℃)
Thermocouple N division (0-1300 ℃)
Thermocouple F2 division (700-2000 ℃)
Thermocouple Wre3-25 division (0-2300 ℃)
Thermocouple Wre5-26 division (0-2300 ℃)
Thermal resistance CU50 (-50.0-150.0 ℃)
Thermal resistance CU53 (-50.0-150.0 ℃)
Thermal resistance CU100 (-50.0-150.0 ℃)
Thermal resistance PT100 (-200.0~650.0 ℃)
Thermal resistance BA1 (-200.0.0~600.0 ℃)
Thermal resistance BA2 (-200.0-600.0 ℃)
Linear resistance 0-400 Ω (-1999~9999)
Remote transmission resistance 0-350 Ω (-1999~9999)
Remote transmission resistor 30-350 Ω (-1999~9999)
0~20mV (-1999~9999)
0~40mV (-1999~9999)
0~100mV (-1999~9999)
-20~20mV (-1999~9999)
-100~100mV (-1999~9999)
0~20mA (-1999~9999)
0~10mA (-1999~9999)
4~20mA (-1999~9999)
0~5V (-1999~9999)
1~5V (-1999~9999)
-5~5V (-1999~9999)
0-10V (-1999~9999) (non switchable)
0-10mA square root (-1999~9999)
4-20mA square root (-1999~9999)
0-5V square root (-1999~9999)
1-5V square root (-1999~9999)
Pulse input (0-10KHz)
Full switch
Special specifications
⑤ Transmission output 1 (OUT1)
code Output type (load resistance RL)
X
0
1
2
3
4
5
8
no-output
4-20mA(RL≤600Ω)
1-5V(RL≥250KΩ)
0-10mA(RL≤1.2KΩ)
0-5V(RL≥250KΩ)
0-20mA(RL≤600Ω)
0-10V(RL≥4KΩ)
Special specifications
⑥ Transmission output 2 (OUT2)
code Output type (load resistance RL)
X
0
1
2
3
4
5
8
no-output
4-20mA(RL≤600Ω)
1-5V(RL≥250KΩ)
0-10mA(RL≤1.2KΩ)
0-5V(RL≥250KΩ)
0-20mA(RL≤600Ω)
0-10V(RL≥4KΩ)
Special specifications
⑦ Alarm output (relay contact output)
code Alarm limit
X
1
2
no-output
1-limit alarm
2-limit alarm
⑧ Communication output/external event input
code Communication interface/digital input interface
X
D1
D2
D3
Y
no-output
RS-485 communication interface (Modbus)
RS232 communication interface (Modbus)
RS232C printing interface
Start, stop, reset
⑨ Feed output ⑩ Power supply
code Feed output (output voltage) code Voltage range
X
1P
2P
no-output
1-channel feeding output
2-channel feeding output
A
D
AC/DC 100-240V(50/60Hz)
DC 20-29V
⑾ Remarks
remarks:

1. When selecting options ③ and ④ and selecting "X" as the input division number, it indicates that there is no compensating flow integrator controller.
2. When selecting, please refer to the wiring diagram to choose the function. Due to the small size of instrument wiring terminals, they may not have full functionality, and some functions can only be selected from one of them on the same group of terminals.
3. When writing the model, it must be complete, and any function items that have not been selected cannot be omitted and must be supplemented with an "X".
Example 1: NHR-5600A-27/X/X-0/X/2/X/X-A (without compensation)
Example 2: NHR-5600A-27/27/14-0/X/2/D1/X-A (temperature and pressure compensation)
4. The input type of the pressure compensation channel only selects voltage or current signals; The input type of the flow channel is only selected as voltage, current, or pulse input, with pulse input only selected for the flow channel.