Welcome Customer !

Membership

Help

Shijiazhuang Aerospace Automation Technology Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Shijiazhuang Aerospace Automation Technology Co., Ltd

  • E-mail

    sjzhangtian@163.com

  • Phone

    137-2278-0778

  • Address

    12-1-502 Rongguo Garden, No. 528 Zhongshan East Road, Chang'an District, Shijiazhuang City

Contact Now

NHR-7300/7300R series LCD PID regulator/regulator recorder

NegotiableUpdate on 08/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Overview: The NHR-7300/7300R series LCD PID regulator/recorder is suitable for high-precision measurement and control systems, and can digitally display and adjust measurement signals such as temperature, pressure, liquid level, and speed; Can choose internal and external given (or valve position) control methods, which can replace amplifiers to directly drive actuators; Programmable control mode can be selected, and 61 target curves can be set to monitor, control, record, and remotely transmit the controlled object. According to the control method, it can be divided into the following categories: NHR-7310/7310R single channel self-tuning PID regulator/regulating recorder. When automatic control is performed, the input measurement value is compared with the internal target value and the control signal is output after calculation. When the NHR-7320/7320R external PID controller/recorder is automatically controlled, the input measurement value is compared with the external input target value and the control signal is output after calculation. When the NHR-7330/7330R valve position feedback PID regulator/control recorder is automatically controlled, there are two control modes based on the different types of control outputs. Firstly, select the analog control output: compare the input measurement value with the internal target value and output the control signal. Mode 2: Select switch control output: When the percentage of control output is less than the valve position feedback value, the instrument output reverses. When the percentage of control output is greater than the valve position feedback value, the instrument output is positive .....

Product Details

overview

The NHR-7300/7300R series LCD PID regulator/recorder is suitable for high-precision measurement and control systems, and can digitally display and adjust measurement signals such as temperature, pressure, liquid level, and speed; Can choose internal and external given (or valve position) control methods, which can replace amplifiers to directly drive actuators; Programmable control mode can be selected, and 61 target curves can be set to monitor, control, record, and remotely transmit the controlled object.

1415955134947645.gifAccording to the control method, it can be divided into the following categories:

NHR-7310/7310R
Single channel self-tuning PID regulator/regulating recorder
During automatic control, the input measurement value is compared with the internal target value and a control signal is output after calculation.
NHR-7320/7320R
External PID regulator/regulation recorder
During automatic control, the input measurement value is compared and calculated with the externally given input target value to output a control signal.
NHR-7330/7330R
Valve position feedback PID regulator/regulating recorder
During automatic control, control is divided into two modes based on the different types of control outputs
Mode 1: Select analog control output: Compare the input measurement value with the internal target value and output the control signal.
Mode 2: Select switch control output: When the percentage of control output is less than the valve position feedback value, the instrument output reverses. When the percentage of control output is greater than the valve position feedback value, the instrument output reverses.
NHR-7340/7340R
Program PID regulator/regulation recorder
According to the requirements of the production process, setting a target curve for control can achieve the operation of running, stepping, pausing, ending, and waiting states for curve control.
 1415954936304105.gifinstrument panel
1.jpg 2.jpg 3.jpg
160 * 80mm (Type A) 80 * 160mm (Type B) 96 * 96mm (Type C)
4.gif ① Display panel
② USB and SD interfaces
③ Confirm button001.gif
Display channel switch key002.gif
Time scale switch, manual/automatic switch key003.gif
④ Right cursor shift key
⑤ Left cursor shift key
⑥ Cursor up key
⑦ Cursor down key
1415954936304105.gifSimple visual indication
5.gif
 1415954936304105.gifWiring diagram

NHR-7310 (R)/7340 (R) series instrument wiring diagram

6.gif

NHR-7320 (R) series instrument wiring diagram

7.gif

NHR-7330 (R) series instrument wiring diagram

8.gif

Note 1: If different functions are marked on the same group of terminals in the wiring diagram, only one function can be selected. If RS485 and RS232 are connected to the same set of terminals, only one can be selected.

Note 2: The direction of the wiring terminals on the back cover of the horizontal and vertical instruments is different, as shown in schematic diagram 1

1416293689658988.gif

 1415954936304105.gifinstrument selectionNHR-73 □-□-□-□-□-□
PID regulator ①②③③③⑤⑥
NHR-73 □R-□-□-□-□-□
PID control recorder ①②③③③⑤⑥
① Control method (Note 1) ② Specification and size
code control mode code Width * Height * Depth

10
20
30
40

Single channel PID control
External given control
Valve position feedback control
Program segment control
A
B
C
160 * 80 * 110mm (horizontal)
80 * 160 * 110mm (vertical)
96 * 96 * 110mm (Method)
③ Control output (Note 1) ④ Alarm output (Note 2)
code Output type (load resistance RL) code Alarm channel (relay contact output)
0
1
2
3
4
5
K1
K3
K4
K5
K6
K7
K8
K9
4-20mA(RL≤600Ω)
1-5V(RL≥250KΩ)
0-10mA(RL≤1.2KΩ)
0-5V(RL≥250KΩ)
0-20mA(RL≤600Ω)
0-10V(RL≥4KΩ)
RELAY CONTACT OUTPUT
Zero crossing trigger pulse output of thyristor
Solid state relay driving voltage output
Phase shifted trigger output
Three phase thyristor zero crossing trigger pulse output
Relay forward and reverse output
Controllable silicon forward and reverse output (suitable for high-power loads)
Solid state relay forward and reverse output
X
1
2
3
4
5
no-output
1-limit alarm
2-limit alarm
3-limit alarm
4-limit alarm
5-limit alarm
⑤ Power supply
code Voltage range
A
D
AC/DC 100~240V(AC/50-60Hz)
DC 20~29V
⑥ Additional functions (all of the following functions can be selected, separated by "/", functions that are not selected can be omitted)
Transmission output (Note 2) Communication output
code Output channel code Communication interface (communication protocol)
1
2
3
1-channel transmission output
2-channel transmission output
3-channel transmission output
D1
D2
D3
RS-485 communication interface (Modbus RTU)
RS232 communication interface (Modbus RTU)
RS232C printing interface
Feed output
code Feed output (output voltage)
1P
2P
1-channel feeding output
2-channel feeding output
Suitable for instruments with records
USB transfer function Extended functionality
code Transfer function code Extended functionality
U USB card transfer (with 1GB USB flash drive) SD SD card expansion (capacity 8GB)
remarks:
1. When selecting external control mode, the control outputs K6, K7, K8, and K9 are not selectable; When selecting valve position feedback control as the control mode, only K7, K8, and K9 can be selected for switch control output; When selecting program segment PID control as the control mode, the control outputs K7, K8, and K9 are not selectable
2. Transmission output and alarm output can be combined, with transmission output+alarm output ≤ 5; When K6 is selected as the control output, the transmission output+alarm output is ≤ 3; When selecting K7 and K8 for control output, the transmission output+alarm output is ≤ 4
3. Example of instrument model:
Example 1: NHR-7310-A-0-2-A-1/D1 (K-even input, 4-20mA output)
Meaning: Single PID control, specifications of 160 * 80 * 110mm, 4-20mA control output, 2-limit alarm output, AC100~240V power supply, 1-channel transmission output, RS485 communication
Example 2: NHR-7330R-A-K7-2-A-1/2P/U (4-20mA input, 4-20mA transmission output)
Meaning: Valve position feedback control, specifications of 160 * 80 * 110mm, relay forward and reverse control output, 2-limit alarm output, AC100~240V power supply, 1 transmission output, 1 feeding output, USB storage function.Input signal type (please specify the signal type when placing an order)
signal type Range of measurement signal type Range of measurement
B
S
K
E
T
J
R
N
F2
Wre3-25
Wre5-26
Cu50
Cu53
Cu100
Pt100
BA1
400~1800℃
-50~1600℃
-100~1300℃
-100~1000℃
-100.0~400.0℃
-100~1200℃
-50~1600℃
-100~1300℃
700~2000℃
0~2300℃
0~2300℃
-50.0~150.0℃
-50.0~150.0℃
-50.0~150.0℃
-200.0~650.0℃
-200.0~600.0℃
BA2
0~400Ω
0~350Ω
30~350Ω
0~20mV
0~100mV
0~20mA
0~10mA
4~20mA
0~5V
1~5V
0~10V
0-10mA square root
4-20mA square meter
0-5V square root
1-5V square root
-200.0~600.0℃
-9999~99999
Special customization
Special customization
-9999~99999
-9999~99999
-9999~99999
-9999~99999
-9999~99999
-9999~99999
-9999~99999
Special customization
-9999~99999
-9999~99999
-9999~99999
-9999~99999
1415955134947645.gifOutput signal type (please specify the signal type when placing an order)
signal type 4-20mA 1-5V 0-10mA 0-5V 0-20mA 0-10V (specially customized)
Load resistance RL RL≤480Ω RL≥250KΩ RL≤960Ω RL≥250KΩ RL≤480Ω RL≥4KΩ