The nursing liquid preparation system equipment is used for online automatic preparation and online CPI/SIP of liquid preparation systems for powder injections, water injections, large infusion solutions, etc. According to the process requirements, configure the operating platform, pipelines, valves, instruments, electrical equipment, and control software to form a complete modular equipment system, and complete factory testing, on-site testing, and services.
Nursing liquid preparation system equipment:
This series of containers has heating and insulation functions, and are manufactured, pressure tested, and accepted according to the "Technical Conditions for Steel Welded Containers".
The sealing of the mixing shaft adopts imported sanitary mechanical seals and leak proof devices. The reducer is selected from Germany's Flender or SEW, and the mixing speed is 36-53 revolutions per minute. Variable frequency drive can also be used for control.
There are various specifications ranging from 100L to 7000L for you to choose from, and we can also design and process according to the actual needs of customers.
The interface adopts a universal ISO standard quick release chuck type, and the inner liner is made of imported 316L or 304.
The tank body is equipped with a liquid level gauge (non-contact ultrasonic, static pressure transmission or glass tube type), an air respirator, a sterilization steam port, a thermometer (digital or dial type), a CIP universal can washer, a light hole sight glass, several inlet and outlet ports, and a manhole.
feature
Internal shape: Vertical cylindrical shape (with the inner cylinder in contact with the medicine solution)
Internal material: 316L (imported)
Internal smoothness: 0.28-0.45 μ m
◆ Exterior material: 304 mirror panel or matte panel
Heating coil: 304
◆ Thermal insulation material: pearl cotton (high temperature resistance, anti-aging)
Exterior temperature: ≤ 10 ℃
◆ Work pressure: normal pressure
Working temperature: 60 ℃~100 ℃
Sterilization pressure: 0.15-0.3Mpa
Sterilization temperature: 121 ℃~132 ℃
to configure:
◆ Deceleration device (German Flender or SEW)
Folding microporous membrane air filter (filters out bacteria ≥ 0.01 μ m)
◆ Liquid level gauge interface (static pressure sensing, ultrasonic, glass tube positioning available for selection)
◆ Interface for thermometer and flow meter (temperature sensor, flow valve)
◆ Exhaust and safety valve interface (connected to a respirator with sterile filtration)
◆ Steam sterilization filtration sterile ventilation interface
◆ Cleaning ball interface (360 degree rotation under low pressure)
◆ Liquid medicine import and export (quick loading type)
◆ Elliptical manhole
◆ Mirror
◆ Lamp hole