OMNIS Mysterious Generation Fully Automatic Karl Fischer Moisture Analyzer

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The OMNIS first generation fully automatic Karl Fischer moisture analyzer is a volumetric Karl Fischer moisture analyzer based on the modular OMNIS first generation platform, making the determination of moisture in samples more convenient, safe, and simple.

Product Details

OMNIS Mysterious Generation Fully Automatic Karl Fischer Moisture AnalyzerIntroduction:

OMNIS Mysterious Generation Karl Fischer Moisture Analyzer is a volumetric Karl Fischer moisture analyzer based on the modular OMNIS Mysterious Generation platform, which makes the determination of moisture in samples more convenient, safe, and simple

  • More user-friendly and significantly reduces manual workload

  • High degree of automation, obtaining faster and more reliable results

  • Using modern liquid adapters to avoid contact with reagents

  • Modular design allows for flexible system upgrades as needed

  • Compliant with FDA 21 CFR Part 11 and EudraLex, Volume 4, Annex 1

  • automation

https://metrohm.scene7.com/is/image/metrohm/Automated volumetric KF titration discover?ts=1643244012316&dpr=off

The OMNIS Mysterious First Generation Karl Fischer Moisture Analyzer has multiple automation solutions that can significantly reduce time-consuming manual work:

After injecting the sample, automatic moisture measurement begins

After the measurement is completed, the used samples are automatically discharged

The titration cell automatically prepares for the next measurement

Automation can perform the same processing on all samples, thereby improving reproducibility and accuracy of results, and simplifying laboratory work.

Faster sample preparation: Using OMNISKF automatic cover removal design can save 25% of time

Higher throughput: With just one additional parallel analysis workstation, it can save 40% of time compared to sequential measurements

Reduce solvent usage: Use OMNIS sample robot, each sample only requires 12mL of solvent

Learn more about the automation of OMNIS's first generation Karl Fischer moisture analyzer

The OMNIS Mysterious First Generation Karl Fischer Moisture Analyzer has multiple automation solutions that can significantly reduce time-consuming manual work:

After injecting the sample, automatic moisture measurement begins

After the measurement is completed, the used samples are automatically discharged

The titration cell automatically prepares for the next measurement

Automation can perform the same processing on all samples, thereby improving reproducibility and accuracy of results, and simplifying laboratory work.

Faster sample preparation: Using OMNISKF automatic cover removal design can save 25% of time

Higher throughput: With just one additional parallel analysis workstation, it can save 40% of time compared to sequential measurements

Reduce solvent usage: Use OMNIS sample robot, each sample only requires 12mL of solvent

Security and traceability

无需接触有毒试剂和溶剂

useOMNIS Mysterious Generation Fully Automatic Karl Fischer Moisture AnalyzerNo need to come into contact with toxic reagents and solvents:

With the help of 3S liquid adapters, there is no need for contact during reagent replacement, and full traceability of reagents can be achieved

All reagents are contained in a closed system

Used reagents are automatically discharged

Automatic filling and emptying of titration tank

Using the OMNIS Mysterious First Generation Karl Fischer Moisture Analyzer, there is no need to come into contact with toxic reagents and solvents:

With the help of 3S liquid adapters, there is no need for contact during reagent replacement, and full traceability of reagents can be achieved.

All reagents are contained in a closed system.

Used reagents are automatically discharged.

Automatic filling and emptying of titration tank.