Welcome Customer !

Membership

Help

Shanghai Keshi Technology Development Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Shanghai Keshi Technology Development Co., Ltd

  • E-mail

    shjxj@126.com

  • Phone

  • Address

    8B, No. 9, Lane 123, Shenmei Road, Pudong New Area, Shanghai

Contact Now

SF6 purity tester

NegotiableUpdate on 11/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

SF6 Purity Tester KS30-CSF6 Purity: Range: 0-100% SF6; (For more accurate purity testing, it is recommended to inform the testing range when purchasing, such as 90% or more, 5% or less, etc.) Accuracy and repeatability: 0.1%, independent of flow rate; Response time: 30 seconds General part: Operating voltage: 220VAC 10% 50Hz, AC/DC dual-use, overcharge protection, continuous operation for no less than 5 hours Storage temperature level: -40~+70 ℃ Output interface: USB1.1 Specification data storage: can store 200 records Operating environment: temperature: -30~+60 ℃ Pressure: 0~20 bar Sample gas flow rate: no impact Other configurations: Standard version management software, including report printing, commonly used conversion tool kit size: 132283308 Application case: On May 21, 2020, in a GIS shell factory in Taizhou, Zhejiang, SF6 gas used for leak detection was gradually mixed with a large amount of air during cyclic use, resulting in a decrease in SF6 purity. The leak detection process has failed. The comprehensive testing instrument includes purity, moisture, and decomposition product testing. SF6 purity testing is commonly used in the following situations: 1. SF6 incoming inspection, usually carried out together with moisture testing; 2. The purity testing of SF6 for recycling mainly involves the mixing of air during the recycling process; 3. SF6/N2 or SF6 dry air, SF6 concentration control for mixed gas distribution; 4. Factory inspection of ring main unit, inflatable cabinet, etc;

Product Details

SF6 Purity Tester KS30-C

SF6Purity:
Range: 0-100% SF6; (To obtain more accurate purity testing, it is recommended to inform the testing range when purchasing, such as 90% or more, 5% or less, etc.)
Accuracy and repeatability: ± 0.1%, independent of flow rate;
Response time: 30 seconds


通用部分:
Working voltage: 220VAC ± 10% 50Hz, AC/DC dual-use, overcharge protection,
Continuous work for no less than 5 hours
Storage temperature level: -40~+70 ℃
Output interface: USB 1.1 specification
Data storage: capable of storing 200 records
Operating environment: Temperature: -30 to+60 ℃
Pressure: 0-20bar
Sample gas flow rate: No impact
Other configurations: Standard version management software, including report printing, commonly used humidity conversion toolkit
Size: 132 × 283 × 308

Application case:
On May 21, 2020, data from SF6 gas testing for leak detection was collected at a GIS shell factory in Taizhou, Zhejiang Province
Due to the gradual mixing of a large amount of air during recycling, the purity of SF6 decreases.
The leak detection process has failed.





The comprehensive tester includes purity, moisture, and decomposition product testing



Common occasions for SF6 purity testing:
1. SF6 incoming inspection is generally conducted together with moisture testing;
2. The purity testing of SF6 for recycling mainly involves the mixing of air during the recycling process;
3. SF6/N2 or SF6 dry air, SF6 concentration control for mixed gas distribution;
4. Factory inspection of ring main unit, inflatable cabinet, etc;