Welcome Customer !

Membership

Help

Dandong Aolong Radiation Instrument Group Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Dandong Aolong Radiation Instrument Group Co., Ltd

  • E-mail

    al@aolongcn.cn

  • Phone

  • Address

    No. 66, Aihe Street, Zhenxing District, Dandong City, Liaoning Province

Contact Now

Small animal 3D scanning Micro CT

NegotiableUpdate on 05/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Small animal 3D scanning Micro CT

Product Details

Small animal 3D scanning Micro CT

Small animal 3D scanning Micro CT

DELPET100.jpg

ChiPet 100 is a multifunctional 3D scanning Micro CT system designed for animals such as ex vivo bones, mice, rats, and rabbits.

It can measure parameters such as bone parameters, brown fat, subcutaneous fat, fatty liver, blood vessels, tumor metastasis, etc.

Capable of conducting bone related research imaging, including arthritis, osteoporosis, bone injury repair, bone regeneration and other fields, and can perform quantitative analysis of bone density, bone microstructure, and bone trabeculae;

Capable of conducting fat research imaging, separating subcutaneous fat, visceral fat, brown fat, and quantitatively measuring fat volume content;

Capable of conducting respiratory imaging studies, obtaining images of the lungs and bronchi in normal or diseased states, and quantitatively analyzing parameters such as volume;

Ø Be able to carry out cardiac research imaging, including myocardial infarction, myocardial hypertrophy, atherosclerosis, cardiovascular disease and other studies, and obtain diastolic and systolic cardiac volume parameters, left ventricular ejection fraction and other functional parameters;

Capable of conducting whole-body vascular imaging research and obtaining high-resolution vascular imaging;

Capable of conducting imaging studies on internal organs such as the liver, spleen, and kidneys, obtaining quantitative parameters such as volume and surface area.

小鼠X光.jpg


  • One click automatic identification of bed load and quick setting

  • Select filter and FOV mode

  • Scanning time: 2 seconds (high-speed mode)

  • 2 μ m high-resolution image

  • The patented bed design can automatically identify and prevent collision

  • Independent hot air system and gas anesthesia stabilize animal vital signs

  • Configure tube energy range: 40-90 kVp, 50W high-energy power supply


产品优势_副本.jpg


intelligent mode Easy to operate, automatically retrieve optimized contrast parameters, scan as long as they fit in, no need to spend time adjusting

  • Automatic detection of animal beds

  • Three modesFOV:rat/mice/in vitro/Ultra high resolution automatic selection

  • Spectrum: Tube Voltage&Additional filters

  • tube current


Technical Parameter

Xx-ray source

40-90 kV, 50W, 15 µmFocus@ 6W

Extra filters

According to the user's selection, additional gifts will be included5A filter

XRadiation detector

1536x 1944, 14positionCMOSdetector, 2x2, 4x4Framed

spatial resolution

44.9, 22.5, 15, 9, 2 um

CTEffective range of detector(Scan space)

80x 200 mm (80mmand40 mmdiameter,Single scan length80 mm)

Reconstruct dimensions

1944*1944*1536

Scan time

Standard:20second. Half scan:2 second.

size(Wx Dx H) cm

880 mm(W)x1500 mm(D)x1500 mm(H)

weight

<850 Kg

Radiation Safety

Distance from the instrument surface during the scanning process5cmAt any point< 5 µSv/h


Test case


Mouse femur

The pixel size in ultra-high resolution mode is9μm.

AAxial and sagittal planes display the structure of mouse femur.

BCoronary slice implanted through bone using titanium material

预临床研究_副本.jpg

Angiogenesis

肺纤维3.jpg


lung metastasis

Mouse mode, 22.5 μ m pixel


normal

正常.jpg

lung metastasis


8 days and 14 days

8天.jpg 14天.jpg

No contrast agent injection. Contrast agent injection


cardiovascular

Tomography of the chest and cardiovascular system: 3D images of the chest and cardiovascular system

心血管.jpg 心血管1.jpg