E-mail
sfybkj@163.com
-
Phone
18915199993
-
Address
No. 8-6 Kejian Road, Dailou Industrial Park, Jinhu County, Jiangsu Province
Jiangsu Sanfeng Instrument Technology Co., Ltd
sfybkj@163.com
18915199993
No. 8-6 Kejian Road, Dailou Industrial Park, Jinhu County, Jiangsu Province
Steam flowmeter/vortex flowmeter/temperature and pressure compensation steam flowmeter/intelligent integrated gas flowmeter
1product overview
SF-LUGBSeries steam flowmeterIt is a new type of flowmeter developed based on the principle of liquid vibration, widely used in the measurement of fluids in industries such as petroleum, chemical, metallurgy, and papermaking. This flowmeter has no movable parts, strong reliability, high accuracy, and long service life, and can accurately measure the instantaneous flow rate and cumulative flow rate of liquids over a wide flow range. It is not affected by the temperature, pressure, viscosity, and composition of the medium, and is not blocked, stuck, easy to scale, resistant to high temperature and high pressure, safe and explosion-proof, suitable for harsh environments. Integrated display and remote transmission of flow scoring, and can output pulse signals or current signals to be networked with a microcomputer.
IISF-LUGBSeries steam flowmetermain features
1The structure is simple and sturdy, with no movable parts, high reliability, and very reliable for long-term operation.
2. Easy installation and convenient maintenance.
3. The detection sensor does not directly contact the measured medium, with stable performance and long lifespan.
4. The output is a pulse signal proportional to the flow rate, with no zero drift and high accuracy.
5. Wide measurement range, with a range ratio of up to 1:10.
6. Less pressure loss, lower operating costs, and more energy-saving significance.
7. Within a certain Reynolds number range, the output signal frequency is not affected by the physical properties and composition changes of the fluid. The instrument coefficient is only related to the shape and size of the vortex generator, and there is no need to compensate when measuring the fluid volume flow rate. After replacing accessories, there is generally no need to recalibrate the instrument coefficient.
8. It has a wide range of applications and can measure the flow rates of steam, liquid, and gas.
IIISF-LUGBSeries steam flowmeterWorking principle
The vortex flow sensor measures flow based on the theories of Kaman and Strouhsl regarding the generation of vortices and the relationship between vortices and flow velocity. When the medium flows through a triangular cylinder at a certain speed, an alternating arrangement of vortex bands is generated behind both sides of the triangular cylinder, known as the "Karman vortex street" (see figure below).
Due to the alternating generation of vortices on both sides of the vortex generator, pressure pulsations are generated on both sides of the generator, resulting in alternating pressure on the detection body. The piezoelectric crystal element encapsulated in the probe generates an alternating charge signal with the same frequency as the vortex under the action of alternating stress. The amplifier amplifies, filters, shapes, and amplifies this charge signal to output a pulse signal with a frequency proportional to the medium flow rate (or converts it into a 4-20mA signal), which is sent to the integrator for processing, display, and control.
Within a certain Reynolds number range (2 × 104~7 × 106), the relationship between the release frequency f of the vortex and the fluid velocity V, as well as the width d of the upstream face of the vortex generator, is expressed as f=St • v/d. In the equation, St is the Strouhal number, which is a dimensionless coefficient. As long as the frequency f is accurately measured, the fluid velocity v can be obtained, and the volumetric flow rate can be calculated from v.
4SF-LUGBSeries steam flowmeterTECHNICAL INDEX
1Measurement media: liquid, gas, saturated vapor, superheated vapor.
2. Accuracy level: ± 1.0% for liquids, ± 1.5% for gases (vapors), and ± 2.5% for insertions.
3. Working pressure: 1.6MPa, 2.5MPa, 4.0MPa, 6.4MPa.
4. Medium temperature: Ordinary type -40~150 ℃ Medium temperature type -40~250 ℃ High temperature type -40~350 ℃.
5. Output signal: Three wire voltage pulse, low level 0-1V, high level>4V, duty cycle 50%; The standard current for two-wire system is 4-20mA; the standard current for two-wire system is 0-10mA.
6. Working environment: -35 ℃ to+60 ℃, humidity ≤ 95% RH.
7. Working power supply: DC12V; DC24V。
8. Shell material: carbon steel, stainless steel.
9. Explosion proof type: intrinsic safety ExibIICT6.
5、 External dimensionsSteam flowmeter/vortex flowmeter/temperature and pressure compensation steam flowmeter/intelligent integrated gas flowmeter
6、 Plug in vortex flowmeter
Insert the vortex street measuring head into a specific position in the pipeline, measure the local flow rate at that location, and calculate the average flow velocity value inside the pipeline based on the velocity distribution relationship of the pipeline section. It consists of a converter, an insertion rod assembly, a ball valve (as required), an installation short tube (ф 100), a vortex street measuring head, etc.
Installation steps:
1. Cut a hole slightly smaller than ф 100 and remove burrs directly above the pipeline where the flowmeter needs to be installed (this requirement applies to horizontal pipelines);
2. Place the short pipe with a flange on top of the hole, keep it perpendicular to the pipeline, and weld it firmly;
3. Place the gasket, insert the flowmeter, and connect the flange. If there is a ball valve at this time, first place the ball valve on the short pipe and connect it, then open the ball valve and insert the flowmeter;
4. Ensure that there is a straight pipe section with a diameter greater than 15D in front of the flowmeter and 5D behind it (D is the inner diameter of the pipeline).
7、 Model selection
The selection of flow meters is a very important task in instrument applications. According to relevant departments, 2/3 of the failures of flow meters in practical applications are caused by incorrect selection and installation. Please pay special attention.
/Temperature and pressure compensation steam flowmeter/intelligent integrated gas flowmeter
| model | describe | ||||||
| SF-LUGB— | □ | □ | □ | □ | □ | □ | |
| Connection method | 1 |
|
|
|
|
| Continuous flange connection |
| 2 | Flange clamping | ||||||
| 3 |
| plug-in | |||||
| Measurement medium | 1 | gas | |||||
| 2 | liquid | ||||||
| 3 | steam | ||||||
| Nominal Diameter | 01 | 15mm | |||||
| 02 | 20mm | ||||||
| 03 | 25mm | ||||||
| 04 | 40mm | ||||||
| 05 | 50mm | ||||||
| 06 | 65mm | ||||||
| 08 | 80mm | ||||||
| 10 | 100mm | ||||||
| 12 | 125mm | ||||||
| 15 | 150mm | ||||||
| 20 | 200mm | ||||||
| 25 | 250mm | ||||||
| 30 | 300mm | ||||||
| structural style | Z | Integrated instrument | |||||
| F | Split type instrument | ||||||
| Converter type | N | Sensor type:+12V or 24V power supply, output three wire pulse signal | |||||
| A | Transmitter type:+24V power supply, output two-wire 4-20mA | ||||||
| B | Intelligent type: Powered by lithium batteries, no signal output displayed on site | ||||||
| C | Intelligent type:+24V power supply, on-site display and output of two-wire 4-20mA | ||||||
| C1 | Intelligent type:+24V power supply, on-site display and equipped with RS485 communication protocol | ||||||
| Explosion proof grade | N | Standard type, not explosion-proof | |||||
| E | Explosion proof type, ExdIIBT6 | ||||||
8、 Requirements for straight pipe sections
In order to ensure the normal and accurate operation of the instrument, there must be a certain straight pipeline upstream and downstream of the sensor installation point to adjust the flow field, as shown in the figure.
Figure 1: Concentric contraction tube;
Figure 2: Concentric expansion tube;
Figure 3: A 90 degree elbow;
Figure 4: Two 90 degree elbows on the same plane;
Figure 5: Two 90 degree elbows in different planes;
Figure 6: The regulating valve should be installed 5D downstream of the sensor. If it must be installed upstream of the sensor, there should be an equal diameter straight pipe section of not less than 50D upstream and an equal diameter straight pipe section of not less than 5D downstream.
9、 Requirements for pipelines
1) The inner diameter D of the upstream and downstream piping is the same as the inner diameter DN of the sensor, and the difference satisfies the following condition: 0.95DN ≤ D ≤ 1.1DN.
2) The piping should be concentric with the sensor, and the coaxiality should be less than 0.05DN.
3) The sealing gasket cannot protrude into the pipeline, and its inner diameter may be slightly larger than that of the sensor.
4) If it is necessary to check and clean the sensor for flow interruption, a bypass pipeline should be installed as shown in the following figure.
/Temperature and pressure compensation steam flowmeter/intelligent integrated gas flowmeter
9、 Requirements for pipeline vibration
Sensors should be avoided from being installed on pipelines with strong vibrations as much as possible. If installation is necessary, shock absorption measures must be taken. Pipeline fastening devices should be installed at the 2D positions upstream and downstream of the sensor, and anti vibration pads should be added.
Special attention: The vibration at the outlet of the air compressor is strong, and sensors cannot be installed. They should be installed after the air storage tank.
/Temperature and pressure compensation steam flowmeter/intelligent integrated gas flowmeter