1、 Scope of application
TXM1 series plastic shell circuit breaker(CM1 molded case circuit breaker)It is a new type of circuit breaker developed and researched using advanced international design and manufacturing technology. Its rated insulation voltage is 690V, suitable for circuits with AC 50Hz, rated working voltage of 400V and below, and rated working current of 800A and below for infrequent switching and motor starting. The circuit breaker has overload, short circuit, and undervoltage protection devices to protect the circuit and power equipment from damage.2、 Model and specifications

3、 Applicable working environment
■ Altitude of 2000 meters and below4、 Main parameters and technical performance
| Shell level rated current lnm (A) | 100 | ||||
| model | TXM1-100C | TXM1-100L | TXM1-100M | TXM1-100H | |
| Rated current ln (A) | 16. 20, 25, 32, 40, 50, 63, 80, 100 | ||||
| number of poles | 3 | 3 | 4 | 3 | |
| Rated insulation voltage Ui | AC800V | ||||
| Rated working voltage Ue | AC400V / AC690V | ||||
| Rated frequency | 50Hz | ||||
| Flashover distance | ≤50mm | ||||
| Rated ultimate short-circuit breaking capacity lcu (kA) | 25 | 35 | 50 | 85 | |
| Rated operating short-circuit breaking capacity lcs (kA) | 18 | 22 | 35 | 50 | |
| Operational performance (times) | Electrical lifespan | 1500 | |||
| mechanical life | 8500 | ||||
| Attachment (optional) | shunt release | ● | ● | ● | ● |
| Undervoltage release | ● | ● | ● | ● | |
| auxiliary contact | ● | ● | ● | ● | |
| Alarm contact | ● | ● | ● | ● | |
| Electric operating mechanism | ● | ● | ● | ● | |
| Rotate the handle operating mechanism | ● | ● | ● | ● | |
| External dimensions | A | 92 | 92 | 122 | 92 |
| B | 150 | ||||
| C | 86 | 104 | |||
| D | 68 | 86 | |||
| Installation size | a | 30 | 30 | 60 | 30 |
| b | 129 | ||||
| φd | 5 | ||||
| Shell level rated current lnm (A) | 225 | ||||
| model | TXM1-225C | TXM1-225L | TXM1-225M | TXM1-225H | |
| Rated current ln (A) | 100, 125, 140, 160, 180, 200, 225 | ||||
| number of poles | 3 | 3 | 4 | 3 | |
| Rated insulation voltage Ui | AC800V | ||||
| Rated working voltage Ue | AC400V / AC690V | ||||
| Rated frequency | 50Hz | ||||
| Flashover distance | ≤50mm | ||||
| Rated ultimate short-circuit breaking capacity lcu (kA) | 25 | 35 | 50 | 85 | |
| Rated operating short-circuit breaking capacity lcs (kA) | 18 | 22 | 35 | 50 | |
| Operational performance (times) | Electrical lifespan | 1500 | |||
| mechanical life | 8500 | ||||
| Attachment (optional) | shunt release | ● | ● | ● | ● |
| Undervoltage release | ● | ● | ● | ● | |
| auxiliary contact | ● | ● | ● | ● | |
| Alarm contact | ● | ● | ● | ● | |
| Electric operating mechanism | ● | ● | ● | ● | |
| Rotate the handle operating mechanism | ● | ● | ● | ● | |
| External dimensions | A | 107 | 107 | 142 | 107 |
| B | 165 | ||||
| C | 110 | 127 | |||
| D | 86 | 103 | |||
| Installation size | a | 35 | 35 | 70 | 35 |
| b | 126 | ||||
| φd | 5 | ||||
| Shell level rated current lnm (A) | 400 | ||||
| model | TXM1-400C | TXM1-400L | TXM1-400M | TXM1-400H | |
| Rated current ln (A) | 200, 250, 315, 350, 400 | ||||
| number of poles | 3 | 3 | 4 | 3 | |
| Rated insulation voltage Ui | AC800V | ||||
| Rated working voltage Ue | AC400V / AC690V | ||||
| Rated frequency | 50Hz | ||||
| Flashover distance | ≤100mm | ||||
| Rated ultimate short-circuit breaking capacity lcu (kA) | 35 | 50 | 65 | 100 | |
| Rated operating short-circuit breaking capacity lcs (kA) | 25 | 35 | 42 | 65 | |
| Operational performance (times) | Electrical lifespan | 1000 | |||
| mechanical life | 4000 | ||||
| Attachment (optional) | shunt release | ● | ● | ● | ● |
| Undervoltage release | ● | ● | ● | ● | |
| auxiliary contact | ● | ● | ● | ● | |
| Alarm contact | ● | ● | ● | ● | |
| Electric operating mechanism | ● | ● | ● | ● | |
| Rotate the handle operating mechanism | ● | ● | ● | ● | |
| External dimensions | A | 150 | 150 | 198 | 150 |
| B | 150 | ||||
| C | 155 | 146.5 | |||
| D | 105 | 106.5 | |||
| Installation size | a | 44 | 44 | 94 | 44 |
| b | 194 | ||||
| φd | 7 | ||||
| Shell level rated current lnm (A) | 630 | |||||
| model | TXM1-630C | TXM1-630L | TXM1-630M | TXM1-630H | ||
| Rated current ln (A) | 250, 315, 350, 400, 500, 630 | |||||
| number of poles | 3 | 3 | 4 | 3 | ||
| Rated insulation voltage Ui | AC800V | |||||
| Rated working voltage Ue | AC400V / AC690V | |||||
| Rated frequency | 50Hz | |||||
| Flashover distance | ≤50mm | |||||
| Rated ultimate short-circuit breaking capacity lcu (kA) | 35 | 50 | 65 | 100 | ||
| Rated operating short-circuit breaking capacity lcs (kA) | 25 | 35 | 42 | 65 | ||
| Operational performance (times) | Electrical lifespan | 1000 | ||||
| mechanical life | 4000 | |||||
| Attachment (optional) | shunt release | ● | ● | ● | ● | |
| Undervoltage release | ● | ● | ● | ● | ||
| auxiliary contact | ● | ● | ● | ● | ||
| Alarm contact | ● | ● | ● | ● | ||
| Electric operating mechanism | ● | ● | ● | ● | ||
| Rotate the handle operating mechanism | ● | ● | ● | ● | ||
| External dimensions | A | 182 | 182 | 240 | 182 | 210 |
| B | 270 | 280 | ||||
| C | 160 | 155 | ||||
| D | 110 | 115.5 | ||||
| Installation size | a | 58 | 58 | 116 | 58 | 70 |
| b | 200 | 243 | ||||
| φd | 7 | |||||
| Shell level rated current lnm (A) | 800 | ||
| model | TXM1-800M | TXM1-800H | |
| Rated current ln (A) | 630, 700, 800 | ||
| number of poles | 33 | 3 | |
| Rated insulation voltage Ui | AC800V | ||
| Rated working voltage Ue | AC400V / AC690V | ||
| Rated frequency | 50Hz | ||
| Flashover distance | <100mm | ||
| Rated ultimate short-circuit breaking capacity lcu (kA) | 75 | 100 | |
| Rated operating short-circuit breaking capacity lcs (kA) | 50 | 65 | |
| Operational performance (times) | Electrical lifespan | 1000 | |
| mechanical life | 2500 | ||
| Attachment (optional) | shunt release | ● | ● |
| Undervoltage release | ● | ● | |
| auxiliary contact | ● | ● | |
| Alarm contact | ● | ● | |
| Electric operating mechanism | ● | ● | |
| Rotate the handle operating mechanism | ● | ● | |
| External dimensions | A | 275 | 275 |
| B | 210 | 210 | |
| C | 107 | 107 | |
| D | |||
| Installation size | a | ||
| b | |||
| φd | |||
5、 Ordering Notice
When placing an order, please indicate the following points:
Product model and name: such as TXM1-225M(CM1 molded case circuit breaker)/TXM1-100H molded case circuit breaker instantaneous tripping rated current: such as 225A.
Polar number: 3P
Order quantity: such as 1000 pieces.
Example of ordering: TXM1CM1 molded case circuit breaker, 1P+N,32A, 6110 pieces.