1、 Scope of application: Intelligent electronic load limiting automatic controller, also known as power limiting automatic controller, current limiting automatic controller, fully automatic current limiting controller. Suitable for AC 50Hz, working voltage 220V, current 0.5-20A, power 110W-4.4kW. It can be used for automatic power control in hotels, student dormitories, factory dormitories, civil buildings on construction sites, and designated power consumption areas. The main purpose is to restrict the illegal use of resistive load power electric heating equipment, such as electric furnaces and fast heating devices, without affecting the use of computers, electric fans, ordinary instruments, televisions, incandescent lamps, electronic fluorescent lamps, etc. (the total power should not exceed the nominal power). Thus, it plays a role in limiting the cost of electricity, especially in limiting the occurrence of fires caused by overcurrent heating in power lines, which helps to eliminate safety hazards. 2、 Model and specifications of automatic power limiting controller
Product Introduction
1、 Scope of application
Intelligent electronic load limiting automatic controllerAlso known asAutomatic power limiting controller,Automatic current limiting controller, fully automatic current limiting controllerSuitable for AC 50Hz, working voltage 220V, current 0.5-20A, power 110W-4.4kW. It can be used for automatic power control in hotels, student dormitories, factory dormitories, civil buildings on construction sites, and designated power consumption areas. The main purpose is to restrict the illegal use of resistive load power electric heating equipment, such as electric furnaces and fast heating devices, without affecting the use of computers, electric fans, ordinary instruments, televisions, incandescent lamps, electronic fluorescent lamps, etc. (the total power should not exceed the nominal power). Thus, it plays a role in limiting the cost of electricity, especially in limiting the occurrence of fires caused by overcurrent heating in power lines, which helps to eliminate safety hazards.
IIAutomatic power limiting controllerModel and specifications
3、 Overload handling method and precautions for load limiting automatic controller
★Load limiting automatic controllerIf the actual load current exceeds the rated current and the time is within 10-50 seconds, the power limiting controller will automatically disconnect the load power supply, and the overload protection indicator red light will automatically light up.
★ Overload handling: First, handle the overloaded load power supply (unplug the illegally used electrical appliances). When the rated current of the power limiting automatic controller is reached, the controller will automatically detect that the load power is lower than the nominal load power. Within 10-50 seconds, the green time indicator light will automatically light up, which can restore normal operation and power supply. Otherwise, the controller will automatically trip continuously and cannot be used normally.
Due to the lack of short-circuit and leakage protection functions in the controller, the input terminal must be connected to a product with short-circuit and leakage protection functions
Due to the automatic recovery function of the controller, when the controller acts to protect and activate, the load (electrical appliance) should be immediately removed and the circuit checked. Otherwise, the controller will automatically trip continuously, and eventually burn out the controller or electrical wiring due to long-term and frequent overload connection and disconnection, causing it to be unable to function normally.
4、 Energy saving and safety
Energy saving: For example, if a dormitory illegally uses 700-1000W electric heating equipment for 2-3 hours a day, at a rate of 0.5 yuan/kWh, it can save 500 yuan in electricity bills per year
◆ Safety: It eliminates the risk of fire caused by overcurrent heating due to the use of high-power illegal electrical appliances and eliminates safety hazards.
5Load limiting automatic controllerMain technical parameters
| working voltage |
AC 220V |
| Protection action current |
0.5A, 1A, 2A, 3A, 5A, 6A, 10A, 15A, 20A (can be customized according to customers) |
| Operating Frequency |
50Hz |
|
Rated current/power
|
0.5A/110W、1A/220W、2A/440W、3A/660W、5A/1100W 6A/1320W、10A/2200W、15A/3300W、20A/4400W
|
| Automatic reset time |
30s±5s |
| Protection action current error |
±10% |
| Self power consumption |
≤1W |
| Electrical and mechanical lifespan |
≥ 100000 times |
| Electrical lifespan |
≥ 100000 times |
| Dimensions (length x width x height) |
85.5×36×66mm |
| Installation method |
35mm rail mounted installation |
| Connection |
N is the neutral line, L1 is the phase line, load output terminal: N is the neutral line, L2 is the phase line. |
VILoad limiting automatic controllerAppearance and installation dimensions
7、 Ordering Notice
When placing an order, please indicate the following points:
Product model and name: such asLoad limiting automatic controllerTXXH
Rated current/power: such as 1A/220V.
Order quantity: such as 360 pieces.