E-mail
changliu006@126.com
-
Phone
18915420690
-
Address
Room 402, Building 117, Shuangyin International, No. 1388 Dongfang Avenue, Wuzhong District, Suzhou
Suzhou Yikang Environmental Testing Co., Ltd
changliu006@126.com
18915420690
Room 402, Building 117, Shuangyin International, No. 1388 Dongfang Avenue, Wuzhong District, Suzhou
| Project Description | |
| Verification of Disinfection Effectiveness in Cleanroomplan | Drafting of Workshop Environment Disinfection Verification Plan |
| Verification of Disinfection Effectiveness in Cleanroomexecute | Floating bacteria, settling bacteria, surface microorganisms |
| Selective use effect and expiration date verification of disinfectants | Draft plan for disinfection and sterilization effectiveness testing and storage validity verification+Detection and verification execution |
| Verification of cleaning effect and storage period of clean work clothes and shoes | Drafting of Verification Plan for Cleaning Effectiveness and Storage Validity of Clean Work Clothes and Shoes+Detection and verification execution |
| Verification of hand, surface clean clothing, and shoe disinfection | Drafting of verification plan for disinfection of hands, surface clean clothing, and shoes+Detection and verification execution |
| Validity verification of workwear wearing period | Drafting of Validity Verification Plan for Work Clothes Wearing+Detection and verification execution |
| Verification of the cleaning and drying effect of raw materials | Drafting of Verification Plan for Raw Material Cleaning and Drying Effect+Detection and verification execution |
| Intermediate storage verification | Drafting of Verification Scheme for Intermediate Product Storage+Detection and verification execution |
| certification program | reference standard |
| clean roomURS | China National Food and Drug AdministrationNMPA |
| Cleanroom and facilities equipment | Guidelines for Drug Production Validation2003Design Standards for Cleanrooms in the Pharmaceutical IndustryGB 50457-2019 |
| Clean transfer window, disinfection and sterilization effect, microbial challenges, | Chinese Pharmacopoeia2020Version Hygiene Standards for Disposable Sanitary ProductsGB15982-2012、 Hygiene Requirements for Ultraviolet DisinfectorsGB28235-2020、 Methods and standards for evaluating disinfection and sterilization effectivenessGB15981-1995 Testing Method for Floating Bacteria in Cleanrooms (Areas) of the Pharmaceutical IndustryGB/T 16293-2010 Test Method for Settling Bacteria in Cleanrooms (Areas) of the Pharmaceutical IndustryGB/T 16294-2010The |