The common faults and solutions of the Cordyceps sinensis ultrafine grinder are as follows:
1. The motor does not run after being powered on
Check the power supply: Confirm that the socket, plug, and power cord are in good contact, and eliminate any loose or broken issues. If the power supply is normal but the motor does not rotate, it may be a fault in the starting capacitor and needs to be replaced or charged for testing.
Mechanical malfunction: Check if the belt has come off or if the motor has burned out. Contact a professional for repair.
2. Sudden shutdown or current fluctuation during operation
Vibration induced short circuit: Check if the door protection switch or forward/reverse travel switch has been damaged or loosened due to vibration, and rewire or replace the wires.
Overload protection: The fluctuation of current may be due to uneven feeding or material accumulation in the crushing chamber. Residual materials need to be cleaned and evenly fed.
3. Decreased production or poor crushing effect
Blade wear: Replace worn hammerheads or blades, adjust the gap between the impact plate and hammerhead.
Insufficient air volume: Check if the air volume of the fan meets the standard, and clean up the blockage of the dust removal equipment.
4. Equipment overheating or abnormal vibration
Bearing lubrication: Supplement or replace deteriorated lubricating oil, and check whether the bearings are damaged.
Loose fasteners: Tighten the anchor bolts of the main engine and motor again, and calibrate the transmission belt.
5. Inlet blockage
Control particle size: Avoid excessive or hard materials and adjust the feeding speed.
6. Daily maintenance suggestions
Regular cleaning: thoroughly clean the crushing chamber, grading wheel, and dust removal device after shutdown.
Check the sealing: replace the aging sealing strip to ensure that the pipeline connection is tight.
The above methods integrate mechanical, electrical, and operational factors, and need to be gradually investigated based on specific fault phenomena.