Phone
13911644071
-
Address
6G, Yaoyan Building, Jiulong Mountain Villa, Xihongmen, Daxing District, Beijing
AGC Instruments Ireland Limited Beijing Representative Office
13911644071
6G, Yaoyan Building, Jiulong Mountain Villa, Xihongmen, Daxing District, Beijing
AGC Stream 6000 Total Carbon and Hydrocarbon AnalyzerThe 23-502 model using flame ionization detector can determine the presence of hydrocarbons in the sample gas.
The all-new Stream 6000 total carbon hydrocarbon analyzer is a brand new product. After successful experiments in the field of simulation, we are pleased to launch a new digital gas analyzer that will help you determine all hydrocarbons in the airflow.
AGC Stream 6000 Total Carbon and Hydrocarbon AnalyzerBy using technology, operators can interact with the instrument through a 5.7-inch QVGA touch screen display. This analyzer will provide better results and additional feature levels, which were not previously available with older instruments.
By using a quality process control device with three built-in spiral coils on the sampling line, users can experience better controllability of the instrument and automatically perform zero point verification, injection, and range verification.
Performance Characteristics:
performance metrics:
Testing Scope |
0.00-20,000ppm(Can be applied on a higher scale) |
resolution |
<0.01ppm |
linear |
0.01-20,000ppm |
zero drift |
<30ppm |
Zui small detection content |
<30ppm |
response time |
<30 seconds |
warm-up time |
Usually 1 hour |
Gas requirements |
Gas: Zero grade H230ml/min Or gas mixture: 40/60% mixture 70ml/min Auxiliary gas: 300ml/min Sample gas: 0.5bar [200kpa] |
flow velocity |
All gas pipelines have flow controllers |
diagnosis |
There are 20 fault codes; The flame extinguishing circuit can automatically cut off the gas and sample gas paths |
interface |
6.5'LED display |
ambient temperature |
15℃--35℃ |
4-20mAoutput |
2Road current circuit; Reverse voltage protection, overvoltage protection. |
alarm output |
The system alarm relay provides passive contacts High alarm, low alarm, fault alarm, sample gas interruption, zero point gas interruption, range gas interruption, flame extinguishing |
solenoid valve |
The internal zero/range/sample solenoid valve can be converted to automatic execution |
Automatic zeroing |
Zero drift can be corrected through an automatic zero adjustment solenoid valve (with adjustable time intervals) |
Automatic calibration check |
Used for comparing current measurements with known standard gases |
Auto Range |
The system will automatically select the range based on the input signal |
data log |
Data can be transmitted to a remote workstation via RS232 10000Measurement values can be stored for future retrieval and querying |
power supply |
115/230 VAC, 50/60 He |
Installation method |
19'Rack mounted, desktop, or wall mounted |
size |
19'(W)*4U(H)*450(D)[483mm×183mm×450mm] |