French AP2E Fuel Hydrogen Laser Analyzer

NegotiableUpdate on 04/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Description: The French AP2E fuel hydrogen laser analyzer uses advanced cavity feedback enhanced infrared laser method to directly measure the concentration of target components in the sample gas. Its application originates from the optical cavity feedback enhanced laser (OFCEAS) technology jointly developed by us and the French laboratory, which greatly improves the optical resolution of the instrument, increases detector sensitivity, and reduces noise interference. It can target impurities such as water, oxygen, total hydrocarbons (calculated as methane), carbon dioxide, carbon monoxide, total sulfur, formaldehyde, formic acid, ammonia, and total halogenated compounds (calculated as halide ions) in hydrogen fuel of proton exchange membrane.
Product Details

France AP2EFuel hydrogen laser analyzerUsing advanced cavity feedback enhanced infrared laser method to directly measure the concentration of target components in the sample gas. Its application originates from the optical cavity feedback enhanced laser (OFCEAS) technology jointly developed by us and the French laboratory, which greatly improves the optical resolution of the instrument, increases detector sensitivity, and reduces noise interference. It can target impurities such as water, oxygen, total hydrocarbons (calculated as methane), carbon dioxide, carbon monoxide, total sulfur, formaldehyde, formic acid, ammonia, and total halogenated compounds (calculated as halide ions) in hydrogen fuel of proton exchange membrane.

Technical advantages:

  • Direct measurement - no need for complicated sample processing, OFCEAS cavity feedback enhanced laser combined with low-pressure sampling can avoid the absorption, desorption, and settling problems of compounds in the pipeline
  • Zero interference phenomenon - OFCEAS low-pressure sampling technology provides high spectral sensitivity, allowing the analyzer to simultaneously measure multiple analytes without interfering with each other (CH4, CO, CO2, H2, H2O, HCl, HCN, HF, N2O, NH3, O2)
  • No need to recalibrate the zero point, no drift - the zero point value has been set inside the instrument and can automatically perform internal zero point calibration
  • Easy operation - pre calibrated for applications, with touch screen and laptop for on-site and remote operation
  • Easy Integration - Digital (Ethernet, RS485, RS232, ModBus) and Analog Output
  • Low maintenance requirements - no optical moving parts
  • High cleanliness pipelines and filters - low pressure, low flow injection (3-9 l/h) combined with instantaneous reaction speed, significantly reducing pollution
  • Safe to use - can be designed for explosion-proof areas

Fuel hydrogen laser analyzerTechnical Specifications:

Model:

PROCESSES

manufacturer:

AP2EFrance

Measurement range and detection limit:

H2:big0-4 vol% (detection limit3 ppm)Optional other ranges

CO2: 0-3 vol% (detection limit2 ppm)

O2: 0-3 vol% (detection limit10 ppm)

H2O: 0-10 ppm (0.1 ppm)

If you have any other requirements, please contact us.

Proton exchange membrane fuel hydrogen

Component detection

Impurities such as water, oxygen, total hydrocarbons (calculated as methane), carbon dioxide, carbon monoxide, total sulfur, formaldehyde, formic acid, ammonia, and total halogenated compounds (calculated as halide ions)

Measurement principle:

Direct and immediate measurement of trace amounts in gases using laser infrared absorption spectroscopygas concentration

Applicable to industry

High purity hydrogen, pure hydrogen, proton exchange membrane fuel cell hydrogen fuel

analyzer

output:

4 - 20 mA x1

Repeatability:

±0.3 % of full scale

Power supply:

230 Vac, 50 Hz, 200 watt

Ambient temperature

15° C to 35° C

French specialized certificate number:

WO & WO 2010058107

Sample gas flow rate:

100 cc/min

Response time:

< 1 sec

Stress

atmospheric pressure

zero drift

none

Operating temperature

10~40

power supply

220 VAC/ 50 Hz (200 Watt)

display screen

5.7”Color touch screen display

software

Windows® 8®(PC OS), Win Proceas©

communication

Ethernet, RS 485, RS 232, Modbus

size

Standard 19 ", 4U cabinet, depth 550 mm

weight

20 kg

Other options

Wall mounted, explosion-proof type