Total hydrocarbon analyzerIt is an instrument mainly used to determine the carbon and hydrogen content in coal and other organic matter. Quantitative samples are burned in an oxygen stream, and the generated water and carbon dioxide are absorbed by water absorbing agents and carbon dioxide absorbents, respectively. The carbon and hydrogen content in coal is calculated based on the increment of absorbents.
Total hydrocarbon analyzerProduct features:
Fully automatic online analysis of total carbon hydrocarbons.
The mainstream touch screen technology makes the operation more concise.
Built in solenoid valve, capable of automatic calibration of range and zero point.
Equipped with an electronic flow meter, the sample gas flow rate is smoother and the measurement is more accurate.
Continuous and uninterrupted measurement and concentration detection of carbon hydrocarbons in the airflow can be carried out, as well as measurement of CO and CO2 content.
Compared with similar products, the LCD touch display screen can be adjusted at any time and has precise readings. AGC company mainly engages in impurity analysis in high-purity gases (99.99% -99.99999%), with sensitivity accurate to ppb level. The smallest detection line can reach 30ppb, and the ultra-high sensitivity and high detection range of the detection line have won high praise from the industry.
Built in FID detector, using digital ignition, can observe whether the flame is successfully ignited through the touch display screen, stable ignition gas path, flame extinguishing, alarm activation will automatically cut off the gas and sample gas paths.
All pipelines are equipped with flow controllers and have 20 fault codes, which can be quickly identified and corrected.
Fault, the system alarm relay provides passive contacts, high and low alarms, fault alarm, sample gas break alarm, zero gas break alarm, range gas break alarm, and flame extinguishing alarm.
Built in solenoid valve, the internal zero point, range, and sample solenoid valve can be turned into automatic execution, zero drift.
It can be calibrated through an automatic zero adjustment solenoid valve (with adjustable time intervals), which can achieve automatic zero adjustment and automatic calibration to check the automatic range.
Data can be transmitted to a remote workstation via RS232, which can store 10000 measurement values for future retrieval and querying.
The main supporting customers include air separation companies such as Hangyang and Linde, as well as complete equipment suppliers such as Beijing Xuedilong and Kailong.
Performance indicators:
Testing Scope |
0.00-20000ppm (can be applied in higher ranges) |
resolution |
<0.01ppm |
linear |
0.01-20,000ppm |
zero drift |
<30ppm |
Zui small detection content |
<30ppm |
response time |
<30 seconds |
warm-up time |
Usually 1 hour |
Gas requirements |
Gas: Zero grade H2 30ml/min Or gas mixture: 40/60% mixture 70ml/min Auxiliary gas: 300ml/min Sample gas: 0.5bar [200kpa] |
flow velocity |
All gas pipelines have flow controllers |
diagnosis |
There are 20 fault codes; The flame extinguishing circuit can automatically cut off the gas and sample gas paths |
interface |
5.7 'LCD with CCFL backlight system; QVGA 320 × 240 resolution pixels; Backlight/Contrast Adjustment |
ambient temperature |
15℃--35℃ |
4-20mA output |
2-channel current circuit; Reverse voltage protection, overvoltage protection. |
alarm output |
The system alarm relay provides passive contacts High alarm, low alarm, fault alarm, sample gas interruption, zero point gas interruption, range gas interruption, flame extinguishing |
solenoid valve |
The internal zero/range/sample solenoid valve can be converted to automatic execution |
Automatic zeroing |
Zero drift can be corrected through an automatic zero adjustment solenoid valve (with adjustable time intervals) |
Automatic calibration check |
Used for comparing current measurements with known standard gases |
Auto Range |
The system will automatically select the range based on the input signal |
data log |
Data can be transmitted to a remote workstation via RS232 10000 measurement values can be stored for future retrieval and querying |
power supply |
115/230 VAC, 50/60 He |
Installation method |
19 'rack mounted, desktop, or wall mounted |
size |
19'(W)*4U(H)*450(D)[483mm ×183mm× 450mm] |