BDJC-50KV Electrical Strength Breakdown Tester
Data transmission and reception
Parameter management: High voltage protection optional, withstand time optional, gradient step optional, leakage current and overvoltage optional, sensitive leakage voltage optional, leakage optional, boost speed can be freely set (0-5kv infinite loop input) Test results optional, remote operation selection, human-machine separation selection, etc
The engineering top uses the volt second characteristic to indicate the breakdown characteristics of insulation under impulse voltage.
Oil bath with easy disassembly and assembly (can be customized according to customer needs, or oil bath can be omitted)
Power supply: 220V ± 10% single-phase AC voltage and 50Hz ± 1% frequency
Eliminating the frequent crashes of old software, poor accuracy, high risk, upgrading the new software with self checking function and warning prompt function, increasing bidirectional judgment of current and voltage, and supporting wireless safety control!
Insurance system
Electrical strength testing, also known as withstand voltage testing. Simply put, any electrical equipment has an insulation level, and the insulation level varies depending on the rated voltage. When a certain voltage level is exceeded, the insulation of the equipment will be broken down. Electrical strength testing is to apply a certain high voltage to the tested equipment (refer to IEC standards or national standards) to see if it will cause breakdown. If it does not break through, it passes; if it breaks through, it indicates that it is unqualified. Usually, this test is conducted before the equipment leaves the factory. On site, it can be done simply by shaking the insulation. In addition, this test is a destructive test and once it breaks down, it cannot be corrected. Electrical strength testing, also known as withstand voltage testing, is the process of examining the characteristics of a coiled insulation material that exhibits conductive properties after being punctured. By querying the changes in electrical parameters, it is determined whether the insulation material has been punctured.
GB12656 Test method for paper frequency voltage breakdown of capacitors
The critical flashover strengths obtained in these situations are referred to as dry flashover strength, wet flashover strength, and dirty flashover strength, respectively. Due to the uneven voltage distribution at the interface of the medium, the flashover voltage along the surface is lower than the breakdown voltage when gas or solid exists alone.
Circuit protection control of this experimental instrument: voltage automatically returns to zero after tripping
ISO 294-1: 1996? Injection molding method for plastic thermoplastic material specimens - Part 1: General principles, multi-purpose molded parts and strip specimens
Test medium: air,
It refers to the quotient obtained by dividing the voltage at which flashover occurs by the leakage distance along the interface of two media or the straight distance between two electrodes under standard experimental conditions. The experimental conditions are divided into several categories, including monotonic conditions, rainy conditions, and dirty conditions.
Safety test door protection
Pressure resistant style: solid; Liquid.
Test leakage protection
Test overcurrent protection
ISO 294-3: 1996? Injection molding method for thermoplastic material specimens in plastic science - Part 3: Small plates? ISO 295: 1991? Plastic thermosetting material compression molded sample
Chassis material: Overall spray coating
Personnel management: Multiple people can be added to use this software simultaneously. Different personnel can set different passwords and cross use without interfering with each other (such as one person using it can delete the set password and directly enter the software)
The discharge along the interface between solid insulation and air, which develops into a penetrating air breakdown, is called flashover. The voltage value required to cause flashover on the outer insulation surface under certain experimental conditions is called the critical flashover strength. Sometimes the flashover strength is indicated by a uniform flashover field strength.
Zero voltage reset protection
Introduction to experimental software:
Note: This section includes methods for determining the surface breakdown voltage of group insulation materials
Test short-circuit protection
Current and voltage stability: External voltage fluctuation of 10% (optional with our company's voltage protector rated fluctuation voltage of 30%)
Voltage endurance time: 0-7H to maintain relative voltage (software setting)
IEC 60455-2, 1998? Orange resin based reactive composites for electrical insulation - Part 2: Test methods? IEC 60674-2: 1988? Plastic films for electrical purposes - Part 2: Test methods
The instrument is equipped with an advanced fault alarm system to prevent users from operating the faulty instrument and causing danger. (Upper computer alarm, lower computer alarm, and zero voltage alarm.)
GB/T1695-2005 Vulcanized Rubber - Test for Power Frequency Voltage Breakdown Strength and Voltage Endurance Strength
The volt second characteristic refers to the relationship curve between the impulse discharge voltage of insulation and the corresponding discharge time under the premise of a certain impulse voltage waveform. The volt second characteristic is determined by experiments, and the method is to maintain the waveform of the impulse voltage unchanged and gradually increase the voltage. When the voltage is low, breakdown occurs at the tail of the wave; When the voltage is very high, the discharge time is reduced to a very small amount, and breakdown can occur at the wave head. When the wave tail hits through, take the amplitude of the impulse voltage as the vertical axis and the discharge time as the horizontal axis.
GB/T 1981. 2-2003? Paint for electrical insulation - Part 2: Test methods (IEC 60464 "2:2001, IDT)
Control method: Wireless Bluetooth control
Relay independent work area
Dimensions: 1800 * 1400 * 600mm
GB/T 10580-2003? Standard conditions for solid insulation materials before and during testing (IEC 60212: 1971, IDT) ISO 293: 1986? Plastic thermoplastic material compression molded specimen
Output voltage: AC 0-50KV; DC 0-50kV
This part of GB/T1408 specifies the test method for measuring the short-time electrical strength of solid insulation materials at power frequency (i.e. 48Hz~62Hz). This part specifies the use of liquid and gas as impregnating agents or surrounding media when testing solid insulation materials, but does not apply to liquid and gas tests
The test of simultaneously measuring the breakdown strength and withstand voltage strength of AC voltage and DC voltage can be set as a gradient withstand voltage test, allowing the gradient time to be freely adjusted.
HG/T 3330 Determination of breakdown strength of insulation paint film
Voltage test accuracy: ≤ 1%
Product advantages:
Real time drawing of experimental curves, display of experimental data, accurate judgment, and the ability to save, analyze, print, and modify experimental data. And extract experimental data for color comparison. Clearly humanized
(Note: Meets standard requirements and can set different boost rates according to user needs)
The insulation strength of external insulation is closely related to external atmospheric conditions, and is influenced by various factors such as atmospheric temperature, pressure, humidity, and dirt. The standard atmospheric conditions of the International Electrotechnical Commission are: pressure of 1013 millibars (1 bar=105 Pa), temperature of 20 ℃, humidity of 11 grams per cubic meter, and the conversion method between external insulation discharge voltages is specified for different atmospheric conditions. The measured voltage values under non-standard atmospheric conditions should be converted to the voltage values under standard atmospheric conditions; On the contrary, when using voltage values under standard atmospheric conditions, they should be converted to voltage values under atmospheric conditions during testing or operation.
Weight: 120kg
IEC 60296: 2003? Specification for unused mineral insulating oils for transformers and switches
Support software sharing and Bluetooth remote operation requirements for different computers.
IEC 60243-1 Test Methods for Electrical Strength of Insulation Materials
Supporting human-machine separation and remote operation, creating a new chapter in domestic control machines (wireless Bluetooth control)
The current can be collected at the mA level and real-time acquisition can be achieved.
Communication test: 1. Constant voltage boost 2. Gradient voltage boost 3. Voltage withstand test
This machine has complete safety protection measures:
Electric Power Industry Standard of the People's Republic of China - Determination of Dielectric Strength of Insulating Oil - DL429.9-91
overvoltage protection
It is determined by experimentation. The engineering top is used to indicate the breakdown characteristics of insulation under the action of impulse voltage.
Result retrieval: Save and retrieve test results, select personnel for retrieval, organize test results according to customer requirements, support color line comparison for more than 5 times, and automatically collect and add test data.
This instrument is controlled by a PC and is completed through our company's independently developed new intelligent digital precision embedded Siemens central unit CPU system and upper computer software control. Data transmission data can be obtained through the PC USB serial port, with a Z-speed of up to 3M/S. RS232 serial port cannot be compared, allowing communication between the upper and lower computers without delay, achieving a truly uniform and accurate boost rate, and accurately measuring leakage current data, with real-time current acquisition.
When the wave head breaks down, the discharge time is taken as the horizontal axis, but the voltage at the time of breakdown is taken as the vertical axis.
Overvoltage can be divided into two categories.
Usage conditions: Environmental temperature: (23 ± 2) ℃ Environmental humidity: (50 ± 5)%\\
Meet the standards:
Boosting rate: adjustable from 0.1KV/s to 5kv/s
Boosting device: using advanced contactless components to uniformly boost voltage, eliminating the previous mechanical voltage regulation
Air switch branch control system
Communication method: Adopting national cutting-edge technology wireless Bluetooth control, supporting 232/USB/Asia Pacific regional network ports
End of experiment discharge protection
Output voltage stabilization system (reducing the difference in output voltage fluctuations)
The test voltage can be continuously adjusted from 0 to 50KV.
DC test: 1. Constant voltage boost 2. Gradient boost 3. Voltage withstand test
Install a highly sensitive overcurrent protection device to ensure that the power is cut off within 0.05 seconds when the sample breaks down.
safeguard:
Normative reference documents
GB1408-2006 Test Method for Electrical Strength of Insulation Materials
Bidirectional voltage and current interference suppression technology
The clauses in the following documents are referred to as clauses in this section of GB/T 1408. Any referenced documents marked with a date shall not be subject to any subsequent amendments or revisions to this section, except for errata. However, parties to agreements based on this section are encouraged to explore the possibility of using the ZX version of these documents. For any reference document without a date, its ZX version applies to this section
Critical flashover strength?
Test method:
Independent grounding protection
You can choose to issue a calibration certificate for national first level measurement units or a certificate for customer specified measurement units
GB/T 7113. 2-2005? Test methods for insulated hoses (IEC 60684-2:1997, MOD)
Electrical capacity: 3KVA
The appearance of this device software is designed by professional graphic designers:
Input voltage stabilization system (reducing external voltage acquisition fluctuations)
The insulation of electrical equipment with volt second characteristics not only bears the effect of long-term working voltage, but also the effect of transient overvoltage.
One type is overvoltage caused by lightning strikes on equipment or induced by lightning strikes near equipment; Another type is overvoltage caused by operations, incidents, or resonances in the power system. The duration of overvoltage is short, but the value of overvoltage greatly exceeds the normal operating voltage. The unfolding of discharge requires a certain amount of time, and under the continuous voltage, the discharge delay has no effect on the discharge voltage;
Input voltage: AC 220V
Wireless Bluetooth control eliminates distance barriers and makes human-machine separation more convenient.
However, regarding the impact voltage with a short duration of action, the influence of discharge delay cannot be ignored.
ISO 10724: 1994? Plastic Thermosetting Molding Plastic Injection Molding Multipurpose Sample
fault alarm system
Liquid "National Standard of the People's Republic of China - Determination of Breakdown Voltage of Insulating Oil GB/T 507-2002"
Mainly applicable to the breakdown strength of solid insulation materials and liquid insulation materials.
The flashover voltage under rainy conditions is lower than that under monotonic conditions, and the flashover voltage along the surface will decrease more significantly under wet and dirty conditions.
ASTM 149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulation Materials at Industrial Power Frequency
High voltage classification: 0-50KV, (adjustable throughout the entire process)
The Siemens CPU central unit processor is currently the most accurate and stable data acquisition system
Equipment malfunction alarm protection
GB/T3333 Test Method for Power Frequency Voltage Breakdown of Cable Paper
?
Breakdown judgment methods: high voltage judgment, leakage current judgment.
Overcurrent protection system
Detection method: automatic cruise detection
The time required to end discharge is shorter when the voltage is high, and longer when the voltage is low
Technical Requirements:
Software misoperation protection