- Phone
-
Address
Building B, 588 Shengang Road, Songjiang District, Shanghai
Shanghai Moxi Scientific Instrument Co., Ltd
Building B, 588 Shengang Road, Songjiang District, Shanghai
Brand Introduction:
The binder company, located in Tuttlingen, southwestern Germany, specializes in the research and production of laboratory temperature control products. Its APT.Line internal preheating technology achieves a very uniform distribution of temperature inside the box, changing the bottleneck of upper and lower temperature difference that traditional preheating systems have been difficult to overcome. The binder temperature control box is widely used in the fields of pharmaceuticals, food, materials science, cosmetics, tobacco, microbiology, chemical engineering, electronics, etc. It is undoubtedly one of the largest and most professional manufacturers of temperature control boxes in the world.
Due to the application of APT Line internal preheating chamber technology, the reliability and control accuracy of the binder biochemical incubator can meet the quality requirements of constant and reproducible cultivation conditions. The BF series forced convection incubator is very suitable for large-scale sample cultivation and situations requiring short temperature recovery time. Its outstanding feature is its high temperature control accuracy, providing constant and reproducible cultivation conditions.
BinderBFHighlight of biochemical incubatoradvantage
APT.Line@Internal preheating technology
Binding Core Technology - APT.Line@Internal preheating technology enables the temperature inside the cavity to reach a very uniform distribution, changing the traditional preheating system's difficulty in overcoming the temperature difference between the upper and lower neck bottles.
Due to the uniform heating process in the preheating chamber, it ensures smooth airflow and uniform temperature distribution inside the chamber.
BF seriesTechnical characteristics of biochemical incubator
1) Electronic control APT.line for forced convection ® Internal preheating technology;
2) Temperature range: 5 ℃ to 100 ℃ above ambient temperature;
3) Digital temperature setting with an accuracy of 0.1 ℃;
4) MS controller, with several timer functions;
5) The timer function of the program controller includes delayed activation, delayed deactivation, and temperature dependent delayed deactivation;
6) The heating rate can be adjusted through a program editor;
7) Fan speed adjustable (0 to 100%);
8) Independent adjustable temperature safety device, Class 3.1(DIN 12880), Equipped with a visual alarm;
9) Internal glass door;
10) 2 stainless steel shelves;
11) RS 422 interface, used for communication software APT-COM ® Data control system; Or use the RS 232/RS 422 interface converter to convert to the printer output port;
12) The interval between printers can be adjusted;
Binder BFTechnical specifications for series biochemical incubators
|
model |
BF 53 |
BF 115 |
BF 240 |
BF 400 |
BF 720 |
|
External dimensions (W × H × D) (mm) |
634×617×575 |
834×702×645 |
1034×822×745 |
1234×1022×765 |
1234×1528×865 |
|
Internal cavity size (W × H × D) (mm) |
400×400×330 |
600×480×400 |
800×600×500 |
1000×800×500 |
1000×1200×600 |
|
Internal cavity volume (L) |
53 |
115 |
240 |
400 |
700 |
|
Stainless steel shelving (standard/maximum) |
2 / 5 |
2 / 5 |
2 / 7 |
2 / 10 |
2 / 16 |
|
Load per shelf/total load (kg) |
15 / 40 |
20 / 50 |
30 / 70 |
35 / 90 |
45 / 120 |
|
Number of doors/Internal glass doors |
1 / 1 |
1 / 1 |
2 / 2 |
2 / 2 |
2 / 2 |
|
Temperature range: ambient temperature+5 to (℃) |
100 |
100 |
100 |
100 |
100 |
|
Temperature deviation @ 37 ℃ (± ℃) |
0.4 |
0.3 |
0.3 |
0.4 |
0.4 |
|
Temperature deviation @ 50 ℃ (± ℃) |
0.7 |
0.6 |
0.8 |
0.9 |
0.6 |
|
Temperature fluctuation range @ 37 ℃ (± ℃) |
0.2 |
0.2 |
0.2 |
0.2 |
0.1 |
|
Temperature fluctuation range @ 50 ℃ (± ℃) |
0.2 |
0.2 |
0.2 |
0.2 |
0.2 |
|
Heating time to 37 ℃ (minutes) |
12 |
22 |
12 |
18 |
21 |
|
Heating time to 50 ℃ (minutes) |
20 |
23 |
24 |
26 |
24 |
|
Recovery time (30 seconds after opening the door to 37 ℃) (min) |
1 |
1 |
1 |
2 |
1 |
|
Recovery time (30 seconds after opening the door to 50 ℃) (min) |
1.5 |
2 |
2 |
2 |
4 |
|
Power supply (± 10% 50/60 Hz) |
230V/0.4KW |
230V/0.4KW |
230V/0.68KW |
230V/0.85KW |
230V/1.25KW |
|
Net weight (Kg) |
43 |
64 |
104 |
145 |
180 |