The cleanroom particle microanalysis aerosol analyzer uses QCM electronic sensors to measure the particle size and concentration of particles/aerosols in the air in real time. The low-pressure impact technology based on the principle of inertial impact is used to collect particle/aerosol samples in stages according to particle size. Crystals with samples can be directly inserted into an electron microscope for scanning electron microscopy and energy dispersive X-ray spectroscopy analysis.

Characteristic
Automatic and rapid measurement of aerosol particle size distribution and mass concentration (μ g/m)3)
Without the need for additional weighing, the mass concentration of PM10 and PM2.5 can be directly calculated
Real time QCM (quartz crystal microbalance) quality sensor
Low aerosol concentration measurement and wide concentration measurement range: 5-1000 µ g/m3Can monitor gaseous aerosols and relatively clean environments
Small particle size can be monitored, with sample particle size as low as 100nm
Automatically control sampling time to prevent QCM overload
Data printing output (particle size distribution bar chart, mass concentration of different particle sizes, sampling time, date)
Computer interface for data collection
The sampling disk can be directly placed into electron microscopes and X-ray scanners for in-depth analysis of the electronic and physicochemical properties of particles
Long term record and wide application
Application
Research on Atmospheric Aerosols
Inhalation toxicology study
Smoke measurement, atmospheric measurement, automotive measurement
Industrial hygiene and occupational safety assessment
Indoor and outdoor air quality analysis
Research on drug aerosols
Parameter
Impactor flow rate: 2SLPM
Total concentration range: 5-1000 µ g/m3
Particle cutting particle size grade of impactor:
| STAGE | D50 |
| Pre separator | >20μm |
| Level 1 | 14μm |
| Level 2 | 10μm |
| Level 3 | 5μm |
| Level 4 | 2.5μm |
| Level 5 | 1.2μm |
| Level 6 | 0.7μm |
| Level 7 | 0.45μm |
| Level 8 | 0.30μm |
| Level 9 | 0.20μm |
| Level 10 | 0.10μm |
*Dynamic diameter equivalent, or equivalent aerodynamic diameter (EAD) based on a particle concentration of 1g/cc
**Mechanical impact plate, blocking particles larger than 20 µ m
***Sum represents the cumulative concentration sum from level 10. Print out PM10 and PM2.5 concentration values, with levels ≥ 3 indicating PM10 values, levels ≥ 5 indicating PM2.5 values, and levels ≥ 6 indicating PM1.0 values
Vacuum pump: High performance, silent, aluminum box protection, linear type, with shock absorber
Impactor pressure difference: total 320mmHg ± 10%
Quartz quality monitoring sensitivity (average): 1ng/Hz
QCM frequency drift (noise): maximum 2 Hz/min after preheating
Initial preheating time for QCM: up to 10 minutes
Temperature range (operation): -20~40 ℃
Power supply and power consumption: 120V 50/60 Hz 50w
Size/Weight:
Impactor 35.5H x12.7W x 30.5L/12, 5.4kg
C/U 17.8H x43.2W x 30.5L/23,10kg
The following is an example of printing measurement data:


Other Model
PC-2 Clean Room Particle Microscopic Analysis Aerosol Analyzer
Measurement particle size range: 0.05~25 µ m
Flow rate: 0.24LPM
Air pump and control unit
Print output of particle size distribution and mass concentration
Measurement of medium and high concentrations, up to tens of milligrams per cubic meter
PC-2H Clean Room Particle Microscopic Analysis Aerosol Analyzer
Measured particle size range: 0.05~10 µ m
Flow rate: 2LM
Air pump and control unit
Print output of particle size distribution and mass concentration
Measurement of medium and low concentrations, a few micrograms per cubic meter
PC-2AS/SK76 Clean Room Particle Microscopic Analysis Aerosol Analyzer
Particle size range measured: 0.14~10 µ m
Flow rate: 0.24LPM
Air pump and control unit
Print output of particle size distribution and mass concentration
12.6LPM high flow rate sampling inlet, equal power flow splitter
Optional high flow rates of 30, 60, and 90LPM
Measurement of aerosol output from special configuration dose inhalers and spray
PC-3HX Clean Room Particle Microscopic Analysis Aerosol Analyzer
Impactor flow rate: 2SLPM
Total concentration range: 5-1000 µ g/m3
Particle cutting particle size grade of impactor:
| STAGE | D50 |
| Pre separator | >10μm |
| Level 1 | 7μm |
| Level 2 | 4μm |
| Level 3 | 2.5μm |
| Level 4 | 1.4μm |
| Level 5 | 0.80μm |
| Level 6 | 0.50μm |
| Level 7 | 0.30μm |
| Level 8 | 0.10μm |
Vacuum pump: High performance, silent, aluminum box protection, linear type, with shock absorber
Impactor pressure difference: total 260mmHg ± 10%
Quartz quality monitoring sensitivity (average): 1ng/Hz
QCM frequency drift (noise): maximum ± 1 Hz/min after preheating
QCM initial preheating time: average 5 minutes, maximum 10 minutes
Temperature range (operation): -20~40 ℃
Power supply and power consumption: 220V 50Hz available
Size/Weight:
Impactor: 35.5h x12.7w x 30.5l/12, 5.4kg
C/U:17.8h x43.2w x 30.5l/23,10kg
IMPAQ AS-6 6-stage impact aerosol sampler
Measured particle size range: 0.5~16 µ m
Flow rate: 12.6LPM
Vacuum pumps, flow meters, and flow control valves
Case
Doctors and scientists at the University of California, San Francisco Medical Center used a QCM aerosol particle size concentration analyzer to monitor blood aerosols caused by surgical equipment and found that blood aerosols could be inhaled by staff.
2. The US Navy will use the QCM aerosol particle size concentration analyzer to monitor the air inside submarines and provide support for improving air purifiers.
3. The QCM aerosol particle size concentration analyzer is used on many research aircraft, including NASA's U-2 and ER-2 aircraft, to monitor the upper atmosphere particle plumes during volcanic eruptions.
4. Hawaiian environmental health scientists used the QCM aerosol particle size concentration analyzer to monitor the volcanic smoke produced by the continuous volcanic eruptions of Mount Chiloa.
5. The micro atmospheric measurement system of the US Department of Energy/Los Alamos National Laboratory uses QCM aerosol particle size concentration analyzer to monitor the particle size distribution and mass concentration in the air, measure the emission plume of diffusion source particles, such as hazardous waste sites.
6. Taiwan Power Company uses QCM aerosol particle size concentration analyzer to assess inhalable radioactive aerosol dose at nuclear power plants.
On October 27, 1993, a wildfire broke out on the southern slopes of the Los Angeles Crest National Forest in northeastern Los Angeles, California. On October 28, the QCM aerosol particle size analyzer was used to monitor the concentration of particulate matter in the air and found that the peak particle size was 0.23um.
8. Taiwan Power Company uses MPS-4G1 microanalysis particle/aerosol sampler to collect radioactive aerosols from nuclear power plants, and analyzes the collected samples using scanning electron microscopy.