Cement level gauge

NegotiableUpdate on 08/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The cement silo level gauge is mainly used for automatic detection and control of the limit level of various materials (such as powder, granular or block) in the silo. Different models of level gauges can meet the requirements of different working conditions, and are widely used in material transportation and control processes in metallurgy, grain, flour, building materials, cement, electricity, coal, chemical industry, casting, rubber, environmental dust removal and other industries. Manufacturer's price: starting from 700.00~80000.00 yuan per batch, 1 unit. Specification parameters: customized processing. Brand: Huayun model AD110A/B/C/D/E/F/G type intelligent radar level gauge. Measurement range: 10 meters, 30 meters, 70 meters. Resolution: 1mm. Measurement accuracy: 3mm. Current signal: 4-20 (mA). Power supply: 220VAC/24VDC. Operating frequency: 26GHz. High frequency process connection. Threaded and flange type. Signal output: 4-20mA. Overlapping with HART and RS485 (MODBU)

Product Details



The cement silo level gauge is mainly used for automatic detection and control of the limit level of various materials (such as powder, granular or block) in the silo. Different models of level gauges can meet the requirements of different working conditions, and are widely used in material transportation and control processes in metallurgy, grain, flour, building materials, cement, electricity, coal, chemical industry, casting, rubber, environmental dust removal and other industries.
水泥料位计|雷达水泥料位计厂家|价格选型
Manufacturer's price:
price ¥ 700.00~80000.00 yuan
Starting from batch ≥1 tower

Specification parameters:
Customized processing correct brand Vauen model AD110A/B/C/D/E/F/G
type Intelligent radar level meter measuring range 10 meters, 30 meters, 70 meters resolution 1mm
measurement accuracy ±3mm current signal 4-20(mA) power supply 220VAC/24VDC
Operating Frequency 26GHz high-frequency Process connection Threaded and flanged signal output 4-20mA stacked with HART and RS485 (MODBU)


The controller adopts the principle of electromechanical level control and measures the material level in contact. When there is no material in the blade part of the silo, the level indicator is powered on, the indicator light is on, and the blade rotates counterclockwise; When there is material in the blade part of the silo, the rotation of the blade is blocked, and the control signal is converted, then the power supply of the level indicator motor is disconnected. This state is maintained until there is no material in the blade part, and the level indicator automatically resets. The motor power is turned on, the indicator light is on, and the blade starts to rotate, and the control signal is switched.


1. Using contact measurement, the results are true, accurate, and reliable; It can be installed horizontally, diagonally, and vertically, making it easy to install and use.

2. Anti interference, ready to use: Due to the absence of complex electronic components and amplification circuits inside, it is not affected by any electromagnetic wave interference and can be used for a long time without any debugging or maintenance after installation.

3. Super strong anti shake performance design: Even when materials flow, no wrong signals will be emitted.

4. Material level display function: Using long-life and high brightness indicator lights, the material level display is intuitive and convenient.

5. Dual protection function: Overload protection function prevents the blades from being damaged by excessive external forces and the motor; The automatic protection function prevents the level indicator from working when the rotation of the material blades in the silo is obstructed, protecting the motor and effectively extending its service life.

6. Excellent measurement reproducibility and adaptability to environmental conditions: i.e. not affected by changes in material particle size, shape, specific gravity, medium, scale, adhesion, temperature, humidity, dust concentration, etc.

7. Super dust-proof sealing performance, even under a pressure of 1MPa, dust cannot enter.

8. Seismic resistance and anti loosening structure design effectively prevent component loosening and slippage; Made of high-quality stainless steel material, it has excellent corrosion resistance and wear resistance.

9. Low price, excellent cost-effectiveness.

Technical Parameter
☆ Power supply: 220VAC/24VDC
☆ Power: 5A/240VAC
☆ Relay output: DPDT (two sets of normally open and normally closed contacts)
☆ Environmental temperature: -40~70 ℃
☆ Delay time: adjustable from 0 to 30 seconds
☆ Sensitivity: 0.3pf~750pf
☆ Probe installation thread: 1 "PT (special specifications can be customized)
☆ Probe material: SUS304/SUS316/PTFE/ceramic
☆ Probe operating temperature: -180~230 ℃ (Max800 ℃)
☆ Shell material: cast aluminum
☆ Protection level: IP66


Product Features
1. Strong universality: widely used for the detection of various material media, including fly ash, particles, powders, liquids, viscous, conductive, and non-conductive materials; It can meet the measurement requirements of different temperatures and pressures, with high temperatures up to 800 ℃ and high pressures up to 5MPA; Can be used in harsh environments such as corrosion and impact.
2. Anti adhesion: The unique circuit design and sensor structure make the measurement ignore the hanging material on the probe and automatically correct it, without the need for regular cleaning, avoiding false measurement and false signal. (Anti hanging material)
3. Maintenance free: There are no movable parts during the measurement process, and there is no mechanical component damage, so no maintenance is required.
4. Powerful function: The output contact capacity is large, and there is a status indicator light to display the working status. The 0 and 30 second delay can eliminate the influence of material fluctuations.
5. Anti interference: contact measurement, with strong anti-interference ability, can overcome the influence of steam, foam and agitation on measurement.
6. Power outage protection: normally open or normally closed (can be switched on-site).
7. Accurate and reliable: Diversified measurement quantities make measurements more accurate, measurement is not affected by environmental changes, high stability, and long service life.

Cement level gauge RF admittance level gauge
Product Outline Drawing


Product Application
1. Conductive and insulating liquids: chemical, oilfield, water and sewage treatment industries, etc
2. Conductive and insulating pastes: industries such as papermaking, pharmaceuticals, water and wastewater treatment, etc
3. Powder, ash, powder: power plants, metallurgy, cement and other industries

4. Particles, coal, grain: power plants, metallurgy, grain and other industries

Installation method.
1. Measure the liquid level of bucket shaped tanks using rod or cable probes:

Note: The probe rod or cable should avoid the opening and feeding port, and the probe rod or cable should be parallel to the warehouse wall. The distance between the warehouse wall should be greater than 200mm.
2. Measure the liquid level of a horizontal tank using a coaxial probe:

Note: Non barrel shaped tanks and non-metallic wall tanks can be measured using coaxial probes.
3. Measure the liquid level of a spherical tank using a connector:

Note: Spherical tanks and other irregularly shaped tanks can be measured using connectors.
4. Use heavy-duty cable to probe the material level of powder or fine particle silos:

Note: The probe should avoid the feeding port. When the warehouse wall is made of concrete, the grounding terminal of the sensor housing should be reliably connected to the concrete reinforcement with a wire.

Installation requirements:
1. The RF admittance switch can be installed vertically or horizontally.
2. During installation, it is necessary to ensure that the center probe and shielding layer of the sensor are not in contact with the container wall (or installation pipe), have good insulation, the installation thread is firmly connected to the container wall, the electrical connection is good, and the shielding layer of the probe should enter the interior of the container.
3. For occasions with mixing, the probe needs to be supported or anchored (the fixed end should be insulated from the probe). The instrument inlet for horizontal installation must be downward, and the explosion-proof pipe for vertical installation must be bottom of the drainage outlet of the inlet to prevent water accumulation in the explosion-proof pipe from endangering the electronic unit of the instrument.
4. Instruments installed according to explosion-proof requirements must be equipped with certified sealing stuffing boxes or explosion-proof steel pipe sealing joints for each wiring connected to the explosion-proof enclosure.
5. Please consult our company and agents for certified sealing stuffing boxes or explosion-proof pipe sealing joint products. The instrument installation area requires lightning protection devices to prevent lightning strikes.
6. The ripple of 24VDC power supply shall not exceed 200mV.
7. The power grounding wire should be connected to the standard ground or standard ground instrument ground, and should not be connected to the power ground.

Installation precautions:
1. The installation position should not be too close to the feeding port, otherwise false echoes may be received during feeding.
3. For cylindrical raw coal bunkers, they should be installed at half the radius of the cylinder, and the sensor should be aligned with the discharge port.
3. Wiring
The required voltage level for level switches varies depending on the model. In order to ensure personal safety and the integrity of the instrument, wiring should be done in the event of a power outage.
The wiring methods are divided into two wire system and four wire system,
As we are collecting a 4-20mA current signal, to prevent electromagnetic interference on site and ensure signal accuracy, shielded cables should be used with one end grounded.
Selection List:

ZWSP100

RF admittance level switch (Zhongwei Measurement and Control), anti heavy hanging material, with switch status indication, independent junction box

2

24VDC

Power supply mode

3

220VAC

0

Standard recording sensitivity

Sensitivity of circuit unit

2

high sensitivity

0

No delay (standard circuit unit)

time delay

1

With delay (adjustable from 0 to 60 seconds) (optional)

2

With delay (adjustable from 0 to 90 seconds) (optional)

Integrated

Instrument type

split type

02

Standard type (temperature<121 ℃)

Electrode type

07

High temperature type (temperature<232 ℃)

20

Flat type

22

Heavy hanging material standard type

30

Flexible probe

55

anti-corrosive

-□□□□

Switch length (mm)

ZWSP100

2

2

1

-

9

02

RF admittance level switch

Electrode selection:

Electrode number

Electrode forms and typical applications

Working temperature and working pressure

length

Diameter

And material

Installation connection

form

02

Standard type: used for liquids, lightweight slurries, and granules (density ≥ 240kg/m3)

121℃/1.38MPa

457mm(18")

9.5 mm/316SS and PTFE

3/4"NPT

07

High temperature type: used for liquids, lightweight slurries, and particles (density ≥ 240kg/m3)

232℃/1.38MPa

457mm(18")

9.5 mm/316SS and T1

3/4"NPT

22

Heavy hanging material standard type: used for mixing liquids, light slurries, and particles (density ≥ 240kg/m3)

149℃/3.45MPa

232℃/1.38MPa

457mm(18")/

914mm(36")

12.7 mm/316SS and TFE

1"NPT

55

Corrosion resistant type: used for liquids, lightweight slurries, and particles (density ≥ 240kg/m3)

232℃/1.38MPa

457mm(18")/

914mm(36")

9.5 mm/316SS and T1

3/4"NPT

20

Flat panel probe: used for detecting blockages in material troughs and hoppers, low material levels

149℃/0.007MP

304.8 * 304.8mm (12 "* 12")/304SS and polyurethane

Mount

30

Flexible probe:

Used in situations where the insertion length of high/low material levels is greater than 15m

82 ℃ atmospheric pressure

15m

4.7mm/304SS and rubber

1"NPT

Note: 1. PTFE is polytetrafluoroethylene; 2. The above are standard lengths and can be produced according to user requirements for switch length.

Design and ordering instructions:
1. Model and specifications of liquid level control device;
2. Measurement range;
3. Work pressure and temperature;
4. Material of control device;
5. Special requirements negotiation;
6. Whether the liquid level device is equipped with flanges, bolts, nuts, valves, sealing gaskets and other accessories on the container for correct selection.