Comprehensive drug high-temperature testing chamber equipment
Comprehensive drug high-temperature test chamberIt is a device that integrates temperature, humidity, lighting, and ultraviolet illumination testing conditions, and can simultaneously meet the requirements of long-term testing, accelerated testing, high-temperature testing, and strong light irradiation testing specified in the pharmacopoeia. It is the preferred solution for pharmaceutical companies to conduct drug stability testing.
Comprehensive drug high-temperature test chamberProduct Features
The products are divided into single box, two box, three box, and multi box types
● Adopting multi-channel touch screen temperature and humidity control instrument
● Temperature and humidity deviation, power outage and other SMS and phone alarm prompts
● Third level permissions and audit tracking
Wireless or wired RS485 communication interface
● Electronic data storage and export
Real time printing
● Accumulated timing
| Single box specification and model | ||||
| Device Model | HZK-150GSD-S/IS | HZK-250GSD-S/IS | HZK-400GSD-S/IS | HZK-500GSD-S/IS |
| Studio size (mm) | 500×500×600 | 550×500×900 | 660×600×1000 | 660×600×1250 |
| Dimensions (mm) | 920×680×1320 | 970×680×1550 | 1080×780×1650 | 1080×780×1720 |
| Installation power | 1500W | 1600W | 2000W | 2100W |
| number of partitions | 2 | 4 | 4 | 4 |
Comprehensive drug high-temperature testing chamber equipment
The low temperature of the constant temperature and humidity incubator does not meet the set indicators in the experiment
It is necessary to observe whether there is a change in temperature, whether the temperature drops slowly or if there is a tendency for the temperature to rise after reaching a certain temperature value.
The former must be checked for the reason, whether the workshop has been dried before conducting the low-temperature test, and after keeping the workshop dry, the test sample should be placed in the workshop for further testing. Then check if there are too many test samples placed in the studio, causing the air inside the studio to not circulate. After ruling out the above reasons, consider whether the refrigeration system of the incubator has malfunctioned. If so, ask the supplier's professional repair personnel for maintenance.