Corrosive liquid level gauge

NegotiableUpdate on 08/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The two-wire liquid level transmitter consists of a special gas conducting cable with a built-in capillary hose, a pressure resistant joint, and a probe. The probe structure of the static pressure level gauge is a stainless steel core with a diaphragm at the bottom and covered by a perforated plastic housing. Manufacturer's price: starting from 1600.00~77000.00 yuan per batch, 1 unit. Specification parameters: customized processing. Brand: Huayun model. MAT-UHZ measurement range: 0~10m. Measurement accuracy: 10mm. Measuring tube material: stainless steel lining PTFE. Applicable range: corrosive liquid pressure range: 2.5MPA. Temperature range: 250 ℃. Liquid level measurement is actually the difference between the liquid static pressure on the measuring probe and the actual atmospheric pressure. Then, the ceramic sensor (attached to the stainless steel film) and electronic components convert the pressure difference into a 4-20mA output signal. Strong corrosive liquid level gauge/sanitary liquid storage container level measurement level gauge is a 26G high-frequency radar level measurement instrument, capable of measuring up to 70 meters at large distances. The antenna has been further optimized and processed, and the new fast microprocessor can perform higher speed signal analysis and processing, making the instrument suitable for very complex measurement conditions such as reaction vessels or solid material silos. The radar level antenna emits narrow microwave pulses, which are transmitted downwards through the antenna. After touching the surface of the measured medium, the microwave is reflected back and then received by the antenna system, which automatically converts it into a level signal by transmitting it to the electronic circuit (because microwave propagation speed is extremely fast, the time it takes for electromagnetic waves to reach the target and reflect back to the receiver is almost instantaneous). Note: When using a high-temperature radar to measure the level of strong dust material, it is essential .....

Product Details



The two-wire liquid level transmitter consists of a special gas conducting cable with a built-in capillary hose, a pressure resistant joint, and a probe. The probe structure of the static pressure level gauge is a stainless steel core with a diaphragm at the bottom and covered by a perforated plastic housing.
腐蚀性液体液位计|磁翻板液腐蚀性液体液位计厂家|价格选型

Manufacturer's price:

price ¥ 1600.00~77000.00 yuan
Starting from batch ≥1 tower

Specification parameters:
Customized processing correct brand Vauen model MAT-UHZ
measuring range 0~10m measurement accuracy ±10mm Measurement tube material Stainless steel lined with PTFE
scope of application corrosive liquid Pressure Range ≤2.5MPA temperature range ≤250℃


Liquid level measurement is actually measuring the difference between the hydrostatic pressure of the liquid on the probe and the actual atmospheric pressure, and then converting this pressure difference into a 4-20mA output signal through a ceramic sensor (attached to a stainless steel film) and electronic components. Strong corrosive liquid level gauge/sanitary liquid storage container level measurement level gauge is a 26G high-frequency radar level measurement instrument, capable of measuring up to 70 meters at large distances. The antenna has been further optimized and processed, and the new fast microprocessor can perform higher speed signal analysis and processing, making the instrument suitable for very complex measurement conditions such as reaction vessels or solid material silos. The radar level antenna emits narrow microwave pulses, which are transmitted downwards through the antenna. After touching the surface of the measured medium, the microwave is reflected back and then received by the antenna system, which automatically converts it into a level signal by transmitting it to the electronic circuit (because microwave propagation speed is extremely fast, the time it takes for electromagnetic waves to reach the target and reflect back to the receiver is almost instantaneous).

Note: When using a high-temperature radar to measure the high dust level, it is necessary to ensure that the * * * high level does not enter the measurement blind zone (area D shown in the figure).
QQ截图20140612105620

Technical advantages

***Large 200m range, stainless steel probe, ceramic diaphragm, rubber seal, long-term stability ≤ 0.15%/year, explosion-proof type optional.


type

It can be divided into two types: input type and side mounted type

CBM-2100 CBM-2700 static pressure level gauge (static pressure level gauge/level transmitter/level sensor/water level sensor) is a pressure sensor for measuring liquid level. The static pressure level gauge (level gauge) is based on the principle that the measured liquid static pressure is proportional to the height of the liquid. It uses advanced isolation type diffusion silicon sensitive elements or ceramic capacitive pressure sensitive sensors from abroad to convert static pressure into electrical signals, which are then temperature compensated and linearly corrected to convert into standard electrical signals (generally 4-20mA/1-5VDC).

The CBM-2100 CBM-2700 series static pressure level gauge (level gauge) is suitable for measuring the level of various media in systems and industries such as petrochemicals, metallurgy, power, pharmaceuticals, water supply and drainage, and environmental protection. The exquisite structure, simple calibration, and flexible installation method provide convenience for users to easily use. Standard signal output modes such as 4-20mA, 0-5V, 0-10mA, etc. can be selected by users according to their needs.

working principle:

When the liquid level transmitter is inserted into a certain depth of the measured liquid, the pressure formula on the sensor facing the liquid level is: Ρ=ρ. g.H+Po

In the formula:

P: Pressure on the liquid surface of the transmitter ρ: measured liquid density

g: Local gravity acceleration

Po: Atmospheric pressure on the liquid surface

H: Depth of liquid input into the transmitter

At the same time, the pressure of the liquid is introduced into the positive pressure chamber of the sensor through gas guiding stainless steel, and the atmospheric pressure Po on the liquid surface is connected to the negative pressure chamber of the sensor to offset the Po on the back of the sensor, so that the pressure measured by the sensor is: ρ g. H. Obviously, by measuring the pressure P, the depth of the liquid level can be obtained.


Functional Features

Good stability, with long-term stability of up to 0.1% FS/year at full and zero positions. Within the compensation temperature range of 0-70 ℃, the temperature drift is less than 0.1% FS, and within the entire allowable operating temperature range, it is less than 0.3% FS.

◆ Equipped with reverse protection and current limiting protection circuits, the transmitter will not be damaged if the positive and negative poles are reversed during installation. In case of abnormalities, the transmitter will automatically limit the current to within 35MA.

Solid state structure, no movable parts, high reliability, long service life.

Easy installation, simple structure, economical and durable.

Main technical parameters:

measuring range

Process: Diffusion silicon ceramic capacitor, sapphire capacitor, optional

Power supply: 7.5-36VDC 24VDC

CBM-2100/CBM-2700 Input Static Pressure Liquid Level Gauge

Reliable anti-corrosion probe with ceramic measuring unit, used for level measurement of clean water, sewage, and saltwater.

application

CBM-2100 CBM-2700 is a pressure sensor (transmitter) used for static pressure level measurement. Hong Kong North Company can provide the following three types:

Outer diameter=22mm (0.87in): suitable for measuring drinking water and small-diameter pipelines

Outer diameter=42mm (1.66in): Heavy duty probe with flush diaphragm for easy cleaning, suitable for sewage treatment plants

Outer diameter=29mm (1.15in): Water tanks with no volume requirements, etc


Its mechanical structure has high resistance to overload and corrosive media

High precision, long-term stable ceramic capacitors and imported diffused silicon measurement units

Sealed electronic module and dual filtering pressure compensation system can resist the impact of climate field changes

An electronic module that can output 4... 20mA signals and is equipped with overvoltage protection

Choosing the integrated temperature sensor Pt100 can simultaneously measure the level and temperature of the material

The corresponding attachments can provide a complete measurement plan

TK-906 Strong Corrosive Liquid Level Gauge/Sanitary Liquid Storage Container Level Gauge/High Frequency Radar Level Gauge Features
The highly corrosive liquid level gauge/sanitary liquid storage container level measurement level gauge adopts a transmission frequency of up to 26GHz, and therefore has the following characteristics:
① Non contact radar, no wear and tear, no pollution
② Small antenna size for easy installation
③ Shorter wavelength, better reflection on tilted solid surfaces
④ The measurement blind spot is smaller, and it can also achieve good results for measuring small cans
⑤ Small beam angle and concentrated energy enhance the echo capability while also helping to avoid interfering objects
⑥ Almost unaffected by corrosion and foam
⑦ Almost unaffected by changes in water vapor, temperature, and pressure in the atmosphere
⑧ Severe dust environment will not affect electromagnetic wave operation
⑨ High signal-to-noise ratio, even in fluctuating conditions, can achieve better performance
⑩ High frequency is the best choice for measuring solids and low dielectric constant media
TK-906 Strong Corrosive Liquid Level Gauge/Sanitary Liquid Storage Container Level Gauge/High Frequency Radar Level Gauge Measurement Parameters
Application: Sanitary liquid storage container, highly corrosive container
Measurement range: 20 meters
Process connection: flange
Medium temperature: -40~150 ℃
Process pressure: atmospheric pressure
Accuracy: ± 3mm
Frequency range: 26GHz
Explosion proof grade: Exib Ⅱ CT6 Gb
Protection level: IP67
Signal output: 4... 20mA/HART (two-wire/four wire)
RS485/Modbus
Installation of TK-906 Strong Corrosive Liquid Level Gauge/Sanitary Liquid Storage Container Level Gauge/High Frequency Radar Level Gauge
Preparation before installation
Please pay attention to the following items to ensure that the instrument can be installed correctly:
① Please reserve sufficient installation space.
② Please avoid installation environments with strong vibrations.

Performance parameter working principle: The magnetostrictive level gauge consists of three parts: the detection rod, the circuit unit, and the float. During measurement, the circuit unit generates a current pulse that propagates downwards along the magnetostrictive line and generates a circular magnetic field. A float is installed outside the detection rod, which moves up and down along the detection rod with the change of liquid level. Due to the presence of a set of permanent magnets inside the float, it simultaneously generates a magnetic field. When the current magnetic field meets the float magnetic field, a "twisted" pulse, also known as a "return" pulse, is generated. Convert the time difference between the "return" pulse and the current pulse into a pulse signal to calculate the actual position of the float and measure the liquid level. The leakage of gasoline into the soil is a more serious problem than the volatilization of gasoline into the air. In developed countries, this is a necessary indicator and also the world's top technology. Jiahe Technology's magnetostrictive level gauge not only measures the liquid level and temperature parameters of oil tanks, but also measures leakage. The leakage accuracy reaches 0.375 liters/hour, which can meet the needs of different users and achieve a high performance price ratio. Main performance: Range: 0~25000mm Accuracy: ± 0.3mm Resolution: 0.1mm Environmental temperature: -25 ℃~70 ℃ Liquid temperature: -25 ℃~150 ℃ Process interface: 3/4 "NPT power supply: DC24V Output signal: 4~20mA, two-wire/four wire system, Temperature measurement: -25 ℃~70 ℃ Temperature error: ± 0.5 ℃ Explosion proof grade: Exia Ⅱ BT4 Communication: RS-485, RS-232, Modbus, Hart and other protocols, can be equipped with CAN bus or according to user requirements. ※ Note: Corresponding management system software that can be configured according to usage requirements can display parameters such as liquid level height, temperature, volume, mass, density, etc. of various media, and can automatically generate reports and print, network distribution, remote monitoring, and other advanced management functions. Application scenarios: Magnetostrictive level gauges are used for industrial measurement and control of liquid levels in various tanks such as petroleum, chemical raw material storage, industrial processes, biochemistry, medicine, food and beverage, tank area management, and underground inventory of gas stations. They are also used for monitoring dam water levels, reservoir water levels, and sewage treatment. Other applications include: 1. Strong reliability: Due to the waveguide principle used in magnetostrictive level gauges, there are no mechanical movable parts, so there is no friction or wear. The entire converter is enclosed in a stainless steel tube, which is non-contact with the measuring medium. The sensor works reliably and has a long service life. 2. High accuracy: Due to the use of waveguide pulses in magnetostrictive liquid level gauges, the measured displacement is determined by measuring the time of the starting and ending pulses during operation. Therefore, the measurement accuracy is high, with a resolution better than 0.01% FS, which is difficult to achieve with other sensors. 3. Good safety: The magnetostrictive level gauge has high explosion-proof performance, intrinsic safety, and safe use, especially suitable for measuring chemical raw materials and flammable liquids. There is no need to open the can lid during measurement to avoid the safety hazards of manual measurement. 4. Magnetostrictive level gauges are easy to install and maintain: Magnetostrictive level gauges are generally installed through existing pipe openings on the top of the tank, and are particularly suitable for the installation of underground and operational storage tanks, without affecting normal production during the installation process. 5. Facilitating system automation work: The secondary instrument of the magnetostrictive level gauge adopts standard output signals, which are easy for the microcomputer to process the signals and achieve networking work, improving the automation level of the entire measurement system.