Elektrophysik (EPK) GalvanoTest 2000 Coulomb Thickness Gauge from Germany-------Can be used for almost all electroplating single-layer or multi-layer coatingsGalvanoTest is a device based on Coulomb principle for measuring coating thickness, which can be used for almost all electroplated single-layer or multi-layer coatings. Chromium, nickel, cadmium, copper, brass, silver, gold, tin, zinc and other electroplated coatings can be measured on metal or non-metal surfaces.The Coulomb electrolytic film thickness gauge produced by Germany's EPK is mainly aimed at some electroplated parts in the plastic, film and other industries, such as galvanizing, silver plating, copper plating on plastics. GALVANOTEST 2000 can test the thickness of single-layer or multi-layer coatings. Electrolytic film thickness gauge, also known as Coulomb coating thickness gauge.
The anodic dissolution method, also known as Faraday Coulomb method, works in the electroplating process: a single metal coating is separated from the substrate by the current of the electrolyte.
The Galvano test determines the thickness of the separated coating by measuring current and time.
Measurement range: 50 nm-75 μ m/0.002-3 mil.

GALVANOTEST 2000The characteristics of the instrument are:
Complies with international standards:DIN EN ISO 2177
GALVANOTEST 2000 measurement principle:
Measure according to Faraday's principle. The process is similar to electroplating, but the direction of the electrochemical reaction is opposite, which is electrolytic plating.
According to the coating/The combination of the substrate and the selection of electrolyte injection into the electrolytic cell. Place the electrolytic cell on the test sample.
A sealing gasket is embedded between the electrolytic cell and the tested sample, which serves to determine the measurement area, for example1mmThe second is to prevent electrolyte leakage.
Electric current passes through the electrolyte and produces electrochemical reactions over a certain area. The thickness of the coating is directly displayed on the digital monitor.
|
GALVANOTESTThe Coulomb coating thickness gauge can measure |
2000 |
3000 |
|
Can measure70More than one plating layer/Matrix combination |
● |
● |
|
Can measure coatings on flat and curved surfaces |
● |
● |
|
Can measure small parts, wires, and linear parts |
● |
● |
|
preset10Measurement parameters for different metals:CrChromiumNiNickelCuCopper, brassZnZincAgSilverSnTinPbLeadCdCadmiumAuGold (requires sample confirmation) |
|
● |
|
preset9Measurement parameters for different metals:CrChromiumNiNickelCuCopper, brassZnZincAgSilverSnTinPbLeadCdCadmium. |
● |
|
|
Users can set it separately8Measurement parameters of metals |
|
● |
|
Users can set it separately1Measurement parameters of metals |
● |
|
|
Measurement institution: |
|
|
|
Equipped with a circulating pump |
|
● |
|
Equipped with an air pump |
● |
|
|
Measurement area: |
|
|
|
a seal8mm2 |
● |
|
|
a seal4mm2 |
● |
● |
|
Sealing sheet1mm2 |
● |
● |
|
Sealing sheet0.25mm2(The coating area is almost too small to be seen) |
|
● |
|
Electrolytic cup0.25-16 mm2(Optional) |
● |
● |
|
Optimization and adjustment of measurement parameters: |
|
|
|
Plating speed0.3-40μm/Minute adjustable |
● |
● |
|
The coefficient can be directly adjusted based on the metal and measurement surface |
● |
● |
|
Calibration with available thickness standard template |
● |
● |
|
Adjustable terminal voltage to resist interference and adapt to coating/Alloy between matrices |
● |
● |
|
GALVANOTESTData storage of Coulomb coating thickness gauge |
|
|
|
The number of different metal measurement parameters that can be stored |
10 |
18 |
|
Storable readings and statistical values |
2000 |
2000 |
|
After the instrument is powered off, all calibration values, readings, and statistical values can be maintained. |
● |
● |
|
Statistical calculation: |
|
|
|
display6Statistical values: mean, standard deviation, coefficient of variation, large and small values, number of readings |
● |
● |
|
Display statistical values immediately or later |
● |
● |
|
Print readings and statistics immediately or later |
|
● |
|
Display and print year, month, day, hour, and minute |
● |
● |
|
Computer interface for peripherals: |
|
|
|
MINIPRINTMini printer interface |
● |
● |
|
RS-232,PCcomputer interface |
● |
● |
|
connectx-tAnalog voltage output interface of recorder |
● |
● |
|
Electrolyte saturation alarm indication |
|
● |
|
Measurement uncertainty: |
|
|
|
5%, in8mm2Under the area, calibrated |
● |
● |
|
Power Supply: |
|
|
|
110/220V,50/60HZ,10W |
● |
● |
|
Size and weight: |
|
|
|
Measurement range:0.05-75μm |
● |
● |