Phone
15921165535
-
Address
No. 418 Huajing Road, Shanzhong Science and Technology Park, Waigaoqiao Free Trade Zone, Pudong New Area, Shanghai
Duzhi Instrument (Shanghai) Co., Ltd
15921165535
No. 418 Huajing Road, Shanzhong Science and Technology Park, Waigaoqiao Free Trade Zone, Pudong New Area, Shanghai
The QNIX1200 adopts an integrated design, requiring only zero adjustment and no calibration, making it easy to use. It can be used to measure coatings and coatings on magnetic substrates such as steel and iron. Easy to operate, convenient to carry, high precision, probe and body are designed at a 90 ° right angle, which can meet the measurement needs of some small spaces (such as pipeline walls) and is loved by a large number of users.When using the instrument for the first time, working on different materials, installing new batteries, or continuously operating the instrument, the instrument needs to be reset to zero. When zeroing, the probe of QNix1200 should be placed on the corresponding zeroing board, or on the workpiece before spraying. Press the probe vertically on the surface of the zeroing board, push either switch on both sides, and the instrument will make a 'drip' sound. Release the switch, lift the instrument up, and zeroing is complete. After zeroing the instrument, the zeroing board should display 0. If the displayed value is too large and exceeds the allowable error range of the instrument, zeroing will fail. Please repeat the zeroing steps above.
The measurement range is 0-2000 μ m or 0-100mil
When the device is turned on, simultaneously push the switches on both sides forward and hold them for one second at a time to switch units.
When the instrument is in storage mode, it can be converted from μ m to mil through corresponding program software.
When the measurement range is 100-999 μ m, the resolution is 1 μ m
The instrument uses a 9V alkaline dry battery, which is installed at the wider end of the instrument.
When the LCD displays' BAT ', it indicates that the battery is running low on power and it is recommended to replace the battery with a new one.
While replacing the new battery, the internally stored data is still retained
Product Features
QNIX1200 measurement range
4. All of themtemperature compensationTechnology makes data more accurate
Instruments without storage function can switch between measurement units by simultaneously pulling the switches on both sides.

QNIX1200 resolution
The use and replacement of QNIX1200 batteries
The resolution of the instrument is related to the thickness of the measured coating, as follows:
The measurement range is 0. 0-99. At 9 μ m, the resolution is 0. 1μm
|
Technical Parameter |
|
|
Magnetic matrix |
FeProbe(QNix1200/1500) |
|
Non-magnetic matrix |
NFeProbe(QNix1500Type) |
|
measuring range |
QNix1200type: 0-2000um QNix1500type: 0-5000um |
|
accuracy |
0-50um:≤±1um 50-1000um:≤±1.5%reading 1000-3000um≤±3% |
|
*Small contact surface |
10×10mm |
|
*Small curvature radius |
Convex surface:5mm concave:25mm |
|
*Small substrate thickness |
Fe:0.2mm/NFe:0.05mm |
|
Temperature compensation range |
0-60℃ |
|
display |
LCDliquid crystal |
|
probe |
Ruby fixed type |
|
power supply |
1×9Vbattery |
|
size |
100×60×27mm |
|
weight |
110g |
|
characteristic |
Right angle design facilitates measurement of the inner wall of the pipe |
|
storage |
1500Memory type storable data |
|
data transmission |
1500Memory type connectable computer |