German Nix QNix 4200 Magnetic Coating Thickness Gauge

NegotiableUpdate on 02/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

QNix 4200 涂层测厚仪只需调零,无需校准,使用简单。QNix®4200(含 QNix®4200、QNix®4200/5、QNix®4200P、QNix®4200P5)可测量磁性金属表面非磁性 涂镀层厚度。

Product Details

Product Description



The QNix 4200 coating thickness gauge only requires zero adjustment, no calibration, and is easy to use.QNix ® 4200 (including QNix) ® 4200 QNix ® 4200/5 QNix ® 4200P QNix ® 4200P5) can measure the thickness of non-magnetic coating on magnetic metal surfaces.


Maintenance and repair:

The electronic technology used in the QNix4200/4500 thickness gauge can meet various measurement requirements. The high-precision equipment, sturdy structure, and ease of use make this instrument widely applicable. As long as it is used and maintained correctly, its lifespan will be very long. The instrument needs to be kept clean, not dropped, and avoid contact with moisture, chemically corrosive substances or gases. After use, the instrument should be placed back in a protective and easy to move box. The drastic changes in temperature will affect the measurement results, so do not directly expose the instrument to strong sunlight or energy that can cause temperature fusion. The instrument is resistant to most solvents, but cannot guarantee the corrosion of a few chemicals. Only by keeping the probe clean can accurate data be obtained. Therefore, it is necessary to regularly check the probe and clean any residual dirt such as paint on the probe. When the instrument is not used for a long time, to avoid damage due to leakage, the battery should be removed. When a malfunction occurs, please do not repair it yourself. Our repair department is always dedicated to serving you. The product comes with a one-year warranty from the date of purchase. Instrument damage caused by ruby wear and tear or other human factors is not covered by the warranty.



Product Features

1. Simple and fast measurement
2. No calibration required
3. Automatic power on/off
4. Dual probe with high cost-effectiveness (QNix 4500/QNix 4500P)
5. Hall sensors make measurements more stable
6. Sound synchronization during measurement
7. Ruby wear-resistant head, long lifespan
8. Backlit LED display for clearer readings
9. Automatically identify and measure the substrate
10. Split type probe to meet different measurement needsQuantity environment (QNix 4200P/QNix 4500P)







Zero position stability:All coating thickness gauges measurePreviously, it was required to calibrate the zero position,Can be found on the instrumentZero calibration plates for instruments or uncoated workpieces.The stability of instrument zero position is a prerequisite for ensuring accurate measurement.A good thickness gauge can maintain zero position for a long time without drifting after zero calibrationEnsure accurate measurement
No calibration required:Most thickness gauges require calibration using standard plates in addition to zero calibration. To measure the thickness within a certain range, it is necessary to calibrate it using a standard sheet within that range. Mainly, it cannot meet the linear accuracy across the entire range. Not only is the operation cumbersome, but it can also cause failure due to rough surface of the standard piece, increasing system errors.
Temperature compensation:The measurement of coating thickness is greatly affected by temperature. The measurement of the same workpiece at different temperatures can result in significant errors. So a good thickness gauge should have ideal temperature compensation technology to ensure measurement accuracy at different temperatures.
Ruby probeThe wear resistance of the probe contact point directly affects the measurement accuracy. Ordinary metal contact probes can cause significant errors due to surface wear.
Special DC sampling technology:This makes the measurement repeatability unparalleled and improved compared to traditional communication techniques.
Detailed description:Measure non-magnetic coatings, coatings, and oxide layers on magnetic metal substrates such as steel, such as paint, powder, plastic, rubber, zinc, chromium, aluminum, etc;



technical parameter

model

QNix 4200

QNix 4500

matrix

Fe

Fe/NFe

measuring range

0~3000μm


Fe: 0~3000μm
NFe: 0~3000μm


accuracy

0~50μm≤±1μm50~1000μm≤±1.5%1000~3000μm≤±3%

*Small contact surface

10×10mm

*Small curvature radius

Convex surface: 3mm /concave: 25mm

*Small substrate thickness

Fe: 0.2mm / NFe: 0.05m

measuring range

0~50℃

Temperature compensation range

-10~60℃

display

LCDliquid crystal

Power Supply

2×1.5Vdry battery

weight

105g

size

100×60×27mm