The high and low temperature alternating test chamber $r $n is suitable for reliability testing of industrial products at high and low temperatures. Testing the performance indicators of components and materials related to electronic and electrical products, automobiles and motorcycles, aerospace, marine weapons, universities, research institutions, and other related products under high and low temperature changes, the products have a wide control range.
High and low temperature alternating test chamber
Product Structure:
Box shell: Cold rolled steel plate with electrostatic spraying;
Insulation material: flame retardant insulation cotton;
Studio material: SUS304 stainless steel plate;
Shelf material: SUS304 stainless steel;
Features
7-inch high-definition touch screen, touch based operation, making the display more intuitive and the operation simpler;
BRIGHT II intelligent operating system can automatically compensate for control parameter values according to environmental changes;
Comes with data management function: The controller can save historical data records, view instrument temperature and humidity record curves, and support exporting with a USB flash drive in an unchangeable file format for viewing and backup, as well as tracing data;
The equipment comes with a circulating air volume regulation system to ensure that there are no dead corners in the airflow and that the temperature distribution is uniform;
Equipped with a controller password lock function to prevent unauthorized operation;
Equipped with program heating function, it can control the heating and cooling rate;
Support multi segment programming program settings;
Equipped with multi-point temperature calibration function, it avoids the need for repeated calibration under different temperature and humidity conditions;
The humidification system is a surface evaporation humidification system independent of the chamber, with the characteristics of low failure rate, good stability, and easy maintenance, ensuring uninterrupted operation throughout the year;
Improve protection functions: upper and lower limit over temperature and over humidity alarm, over temperature shutdown protection, door opening alarm, water shortage alarm, sensor fault alarm, overload protection, leakage protection, compressor over temperature protection, fan over temperature protection, sample over temperature function, etc.
Reference standard GB/T 10592-2008
core component
Adopting imported energy-saving and environmentally friendly compressors, imported high-performance fans, and imported high-precision temperature and humidity sensors.
structural characteristics
Equipment configuration includes communication ports such as USB interface and RS485 interface;
Standard configuration includes a verification port for user temperature calibration or verification;
The outer door is equipped with a mechanical lock to prevent unauthorized opening;
Equipped with a detachable compressor condenser maintenance window, convenient for customers to regularly clean the condenser;
Equipped with an observation window anti fog system and a condensation water recovery system inside the chamber;
Manufacturing standards and application standards
The manufacturing standard refers to the relevant standards of GB/T 10586-2006 "Technical Conditions for Damp Heat Test Chamber" for manufacturing.
Can meet the requirements of GB/T 2423.1-2423.4 "Environmental Testing for Electrical and Electronic Products" for low temperature, high temperature, constant humidity and heat tests, and alternating humidity and heat tests.
High and low temperature alternating test chamber
Technical Specifications
| model |
BXGDS-50A(B、C、D) |
BXGDS-100A(B、C、D) |
BXGDS-250A(B、C、D) |
BXGDS-500A(B、C、D) |
BXGDS-1000A(B、C、D) |
| Temperature control range |
A: -20℃-150℃ B: -40℃-150℃ C: -60℃-150℃ D: -70℃-150℃ |
| temperature resolution |
0.1℃ |
| Temperature fluctuation (at 37 ℃) |
≤±0.5℃ |
| Temperature uniformity (at 37 ℃) |
≤±2℃ |
| Moisture control range |
20-98%RH |
| Humidity resolution |
0.1%RH |
| Humidity fluctuation |
≤±3%RH |
| heating rate |
≥3℃/min |
| 降温速率 |
≥0.7℃/min |
| Inner container size (length/width/height) mm |
400×300×400 |
500×400×500 |
600×550×750 |
800×800×800 |
1000×1000×1000 |
| Dimensions (length/width/height) mm |
600×1280×1520 |
700×1380×1620 |
800×1180×1850 |
1000×1450×1780 |
1200×1980×2100 |
| Shelf (block) |
2 |
2 |
2 |
3 |
4 |
|
Power supply (V)/
Power (KW)
|
A |
380/2.5 |
380/4.5 |
380/5 |
380/5.5 |
380/6 |
| B |
380/3.5 |
380/5.5 |
380/6.5 |
380/7.5 |
380/8.5 |
| C |
380/4.5 |
380/5.5 |
380/7.5 |
380/8.5 |
380/10.5 |
| D |
380/4.5 |
380/5.5 |
380/7.5 |
380/8.5 |
380/10.5 |
| Gross weight/net weight (kg) |
185/145 |
240/175 |
320/225 |
415/315 |
482/357 |
| Outer packaging size (mm) |
920×980×1620 |
800×1420×1720 |
900×1580×1950 |
1100×1550×1880 |
1300×2080×2210 |
optional
| name |
description |
| printer |
Real time printing of date, time, temperature data, and other information. |
| Softening water device |
Ensure the quality of incoming water, reduce equipment maintenance frequency, and extend the service life of humidification components. |