structural characteristics
Drawer style shelf design, convenient for layout and sampling, supports arbitrary positioning, the shelf adopts reinforced design, and the load capacity is increased by more than 1.5 times;
Using high-quality insulation materials to enhance the overall performance of the machine;
The rotating two-stage locking structure ensures a higher fit between the door and the inlet seal, achieving good sealing performance;
Preheating chamber design, where air is heated and mixed directly into the working chamber to ensure rapid heating and good heat distribution effect;
The four corners of the cavity are designed with rounded corners, and the shelf is easy to disassemble and clean;
Comes standard with one 485 interface;
Optional: printer, online monitoring platform, air inlet and outlet filters, GPRS SMS alarm
Features
LCD display screen, real-time display of set temperature and actual temperature values, operating status, number of fan segments, and working status;
Backlit touch sensitive buttons, easy to operate, and low failure rate;
The BRIGHT I control system can automatically compensate for control parameter values based on environmental changes;
Equipped with a countdown reservation function, the reservation time range is 0~9999 minutes/hour;
Programmable programming: 10 segments with 100 cycle program settings;
6-stage speed regulation of the fan can ensure the requirements of different wind speeds and avoid sample loss caused by dust and sample dust;
The air door is electrically adjustable, and the air exchange rate inside the chamber can be adjusted according to different samples or heating rates;
The dual over temperature alarm function (a. controlled by a temperature sensor system, b. independent temperature control switch) ensures the safe operation of the equipment when there is no one on duty.
Reference standard GB/T 30435-2013
Technical Specifications:
Model: BXLH-130A
Temperature control range: RT+5-100 ℃
Heating time (60 ℃): 20min
Temperature uniformity (37 ℃): ± 0.8 ℃
Temperature fluctuation (37 ℃): ± 0.3 ℃
30 seconds recovery time (60 ℃): 13 minutes
Rated power (kW): 0.5
Capacity: 129L
Inner container size: 570 × 400 × 570mm
Dimensions: 715 × 616 × 842mm
Load carriers (standard/maximum): 2/7 pieces
Does it support overlapping stacking/layers: Yes/Two layers