E-mail
1702662999@qq.com
-
Phone
18915186518
-
Address
No. 99 Tongtai Avenue, Industrial Concentration Zone, Jinhu County, Jiangsu Province
Jiangsu Huayun Instrument Co., Ltd
1702662999@qq.com
18915186518
No. 99 Tongtai Avenue, Industrial Concentration Zone, Jinhu County, Jiangsu Province
The kerosene level gauge manufacturer is a product introduced and absorbed by the company from foreign similar products, and developed and produced with improvements. The series of products can achieve high sealing, leak prevention, and safe and reliable measurement of liquid level under high temperature, high pressure, high viscosity, and strong corrosive conditions. The entire measurement process has no blind spots, eye-catching display, intuitive reading, and a large measurement range. Equipped with liquid level alarm and control switch, it can realize upper and lower limit alarm and control of liquid level or boundary. Paired with LB type liquid level transmitter, it can convert liquid level and boundary signals into two-wire 4-20mADC standard signals, realizing remote detection, indication, recording, and control. The series of products are widely used for liquid level measurement and control in various industries such as power, petroleum, chemical, metallurgy, environmental protection, shipbuilding, construction, and food production processes.
Manufacturer's price:
| price | ¥ 600.00~85000.00 yuan |
| Starting from batch | ≥1 tower |
| Customized processing | correct | brand | Vauen | model | LKUHZ |
| measuring range | 1-20m | resolution | 10mm | Supply Voltage | 24v |
| External dimensions | 0(mm) | Explosion proof grade | 0 | measurement accuracy | 10mm |
Structural principle of kerosene level gauge manufacturer:
The liquid level gauge works based on the principles of buoyancy and magnetic coupling. When the liquid level in the tested container rises or falls, the float in the main tube of the level gauge also rises or falls accordingly. The magnetic steel inside the float is transmitted to the on-site indicator through magnetic coupling, driving the red and white flip columns to flip 180 °. When the liquid level rises, the flip column changes from white to red, and when the liquid level drops, it changes from red to white. The red and white boundary of the indicator is the actual height of the medium liquid level in the container, thus achieving the indication of the liquid level.
The significant feature of the magnetic flap level gauge is that the liquid medium is completely isolated from the indicator, making it very safe, reliable, and durable in any situation. Various models of level gauges are equipped with level alarms and control switches, which can achieve upper and lower limit alarm, control, or interlocking of the liquid level or boundary. When equipped with static pressure level transmitters or dry spring resistance level transmitters, the liquid level and boundary signals can be converted into two-wire 4-20mADC standard signals, realizing remote indication, detection, recording, and control. Suitable for liquid level measurement in corrosive media and high operating temperatures, with reliable structure and long service life. It is the best choice for measuring the liquid level of highly corrosive media such as hydrofluoric acid. Tailored for customers with low temperature and pressure requirements, our PP material level gauge can be used.
Users can use remote transmitters according to engineering needs, which can achieve local digital display and output standard remote transmission electrical signals of 4-20mA to meet the needs of recording instruments or industrial process control. It can also be used in conjunction with magnetic control switches or proximity switches to monitor liquid level alarms or control inlet and outlet equipment.
1、 Difference in lining selection:
The stainless steel lined anti-corrosion magnetic flap level gauge adopts a stainless steel body lined with polypropylene (PP) and polytetrafluoroethylene (PTFE) technology, which has high structural strength and corrosion resistance, and can be applied to acidic liquids such as hydrochloric acid, alkaline liquids, and organic solvents. But it is not suitable for measuring concentrated nitric acid, chlorine containing solvents, aromatic agents, aliphatic and other medium liquids. There are two types of side mounted anti-corrosion magnetic flap level gauges with stainless steel main body lined with polytetrafluoroethylene (PTFE) and stainless steel lined with polypropylene (PP), which are suitable for measuring corrosive media.
The side mounted lined magnetic flap level gauge (PTFE) is suitable for measuring liquid levels in corrosive media and high operating temperatures. It adopts advanced stainless steel lined PTFE stretching and flanging technology, with reliable structure and long service life. It is the best choice for measuring the liquid level of highly corrosive media such as hydrofluoric acid.
The side mounted lined magnetic flap level gauge (PP) is suitable for measuring inorganic corrosive liquids such as hydrochloric acid and dilute sulfuric acid. Due to the use of imported high-strength materials that can be close to metals, especially the unique insulation properties of PPR, this product is suitable for outdoor water tank level measurement and will not freeze inside in winter But it is not as good in temperature and pressure resistance as PTFE lining, and this product has a higher cost-effectiveness when the temperature and pressure are lower.
2、 Characteristics:
1. Using a float as the measuring element and a magnetic steel driven flip column display, no energy is required.
2. Equipped with upper and lower limit switch outputs, it can achieve remote alarm and limit control.
3. Equipped with a transmitter, remote liquid level indication, detection, and control can be achieved.
3、 Installation and maintenance
1. The installation must be vertical to ensure that the floating ball component can move freely up and down inside the main tube.
2. No magnetic conductors are allowed to approach the main body, otherwise it will directly affect the correct operation of the liquid level gauge.
3. After installation, it is necessary to calibrate the flip column guide with magnetic steel to display red below zero position and white above zero position.
4. When the liquid level gauge is put into operation, the valve of the lower drainage pipe should be opened first to allow the liquid medium to smoothly enter the main pipe, avoiding the liquid medium from rapidly rising with the floating ball component, which may cause failure and disorderly flipping of the column. If this phenomenon occurs, it can be recalibrated with magnetic steel after the liquid level stabilizes.
4、 Basic technical parameters:
1. Range: above 250mm;
2. Medium density: ≥ 0.4g/cm3;
3. Medium viscosity: ≤ 0.02Pa.S;
4. Working temperature: PP-40~80 ℃, PTFE -40~150 ℃;
5. Pressure rating: ≤ 32MPa;
6. Measurement accuracy: L=500~1000mm ≤ 1.5% FS, L>1000mm ≤ 1.0% FS;
7. Installation methods: side mounted, top mounted;
8. Protection level: IP65;
9. Explosion proof level: ib Ⅱ CT4 (intrinsic safety type), d Ⅱ BT4 (explosion-proof type);
10. Transmission mode: 4-20mA or switch quantity;
11. Wetting material: PP, PTFE;
12. Float material: 316L, PVC/UPVC/CPVC/PTFE/titanium, etc.
5、 Manufacturer's purpose and scope of application of kerosene level gauge:
|
type |
model |
Scope and Application |
|
Common |
AK-UHZ -P |
Ordinary float level gauge is a type of on-site display instrument widely used in petroleum, chemical, power, light industry, environmental protection and other departments to continuously display the liquid level in open or pressure vessels. |
|
Anticorrosive type |
AK-UHZ- F |
Especially suitable for liquid level measurement indicators with corrosiveness and toxicity (working pressure ≤ 1.6MPa); Measurement range ≤ 2m). |
|
Heat tracing type |
AK-UHZ- R |
Suitable for measuring liquid media with high viscosity, high or low temperature (this instrument requires the use of a heat tracing device). |
|
High temperature type |
AK-UHZ- T |
Suitable for continuous liquid level measurement of liquid media with container pressure less than 10Mpa and temperature between 200 ℃ and 450 ℃. |
|
High pressure |
AK-UHZ- Y |
Suitable for measuring the liquid level of liquid media in closed containers with temperatures below 200 ℃ and process pressures above 10Mpa (below 20Mpa). |
|
High temperature and high pressure type |
AK-UHZ- H |
Suitable for measuring the liquid level of liquid media in closed containers with temperatures above 200 ℃ and process pressures above 10Mpa (below 20Mpa). |
|
Explosion proof type |
AK-UHZ -B |
This instrument is suitable for situations where remote transmission of electrical signals is required in flammable and explosive environments. It comes with electronic devices such as 4mA to 20mA current signals or liquid level transmitters with upper and lower limit alarm settings. |
|
Top mounted type |
AK-UHZ -D |
Suitable for various underground fluid storage tanks, it can display liquid level on the ground. Not suitable for working environments with strong vibrations and strong magnetism (working pressure ≤ 1.6MPa); Measurement range ≤ 2m).
|
6、 Kerosene level gauge model and description:
|
AK-UHZ |
Manufacturer number |
|||||||||||||
|
|
code |
meaning |
T |
High temperature type |
Basic type |
|||||||||
|
|
P |
Common |
Y |
High pressure |
||||||||||
|
|
D |
Top mounted type |
H |
High temperature and high pressure type |
||||||||||
|
|
F |
Anticorrosive type |
B |
Explosion proof type (Bd is explosion-proof type, Bi is intrinsic safety type) |
||||||||||
|
|
R |
Heat tracing type |
|
|
||||||||||
|
|
code |
meaning |
4 |
4.0 |
Process pressure (MPa) |
|||||||||
|
|
0 |
Atmospheric pressure |
5 |
6.3 |
||||||||||
|
|
1 |
1.0 |
6 |
10.0 |
||||||||||
|
|
2 |
1.6 |
7 |
15.0 |
||||||||||
|
|
3 |
2.5 |
8 |
other |
||||||||||
|
|
code |
meaning |
4 |
0.75-0.9 |
Medium density (g∕cm3) |
|||||||||
|
|
1 |
0.45-0.51 |
5 |
0.9-1.0 |
||||||||||
|
|
2 |
0.51-0.65 |
6 |
1.0-1.8 |
||||||||||
|
|
3 |
0.65-0.75 |
|
|
||||||||||
|
|
code |
meaning |
2 |
PVC/ UPVC |
Material |
|||||||||
|
|
0 |
304 |
3 |
Lining F4 (or PE) |
||||||||||
|
|
1 |
316/ 316L |
4 |
other |
||||||||||
|
|
0 |
Column flipping on-site display type |
Display mode |
|||||||||||
|
|
1 |
Transmission output type |
||||||||||||
|
|
2 |
Flip column with transmission output type |
||||||||||||
|
|
3 |
Other types |
||||||||||||
|
|
0 |
No alarm point |
Alarm code |
|||||||||||
|
|
1 |
There is an alarm point |
||||||||||||
|
|
2 |
There are two alarm points |
||||||||||||
|
|
3 |
other |
||||||||||||
|
|
X |
Other content such as range (L) |
Other options |
|||||||||||
|
7. Installation requirements for kerosene level gauge: 1. If your design process involves connecting flanges that are different from our company's model or using other standards, we can supply according to your requirements; 2. The measurement range of the instrument is the center distance between two connecting flanges (excluding top mounted types), where the center of the lower connecting flange is the zero point indicated by the instrument; 3. The measurement range of the instrument is the center distance between two connecting flanges (excluding top mounted types), and the length of the distance between the drain valve and the center distance of the flange is determined by the density of the applicable medium 4. You should ensure that the end faces of the connecting flanges on the equipment have appropriate flatness, perpendicularity, and center distance to ensure the installation and use of our products; 5. The float chamber (or main tube) should be kept clean and free of impurities, especially ferromagnetic substances. When the medium is not clean, adsorption or filtration devices should be added to ensure the normal operation of the instrument.
2. A liquid level gauge with a transmission output electrical signal, whose medium temperature does not exceed 100 ℃ or requires cooling treatment. Top mounted magnetic flap level gauge and side mounted magnetic flap level gauge. Technical parameters of magnetic flap level gauge:
Measurement range: 0-150-6000mm (can be negotiated for orders larger than 6000mm), degree: ± 10mm Medium density: 0.4-20g/cm3, medium density difference: ≥ 0.15g/cm3 Work pressure: -0.1-42MPa Working temperature: -160-450 ℃ Connection flange: The flange diameter is DN20-DN150, and the flange standard adopts the HG20592-97 flange standard of the Ministry of Chemical Industry. For other flange standards, please indicate them when ordering. Environmental vibration: frequency ≤ 25HZ, amplitude ≤ 0.5mm. Flange material: carbon steel, 304, 316L Follow speed: ≤ 0.08m/s Medium viscosity: ≤ 0.04Pa Main pipe material: 1Cr18Ni9Ti, 304, 316L, PP, PTEE, lined with 304 stainless steel PTEE. Main pipe diameter: ¢ 48, ¢ 57, ¢ 62mm. Magnetic flip column material: ≤ 80 ℃: ABS plastic, ≥ 80 ℃: ceramic or metal. Display material: ≤ 80 ℃: ABS plastic, ≥ 80 ℃: aluminum alloy. Installation method: Vertical installation. Discharge valve: ball valve, needle valve. Top mounted magnetic flap level gauge Side mounted magnetic flap level gauge Magnetic flap level gauge Product features: The components of the UHZ series magnetic flap (column) level gauge are made of 1Cr8NiTi, 316L, 304 stainless steel lined with PTEE (polytetrafluoroethylene), PVC, PP and other materials, as well as imported components, which have high reliability and corrosion resistance. Its characteristics are very significant: The design is simple, compact, sturdy and reliable, with a long lifespan and no maintenance work required for long-term outdoor installation and use; The measuring tube is completely isolated from the liquid level display part, liquid level transmitter, and alarm switch in terms of pressure resistance and gas resistance; Wide range of working pressure, with pressure resistance ranging from vacuum to 42MPa; Wide working temperature range, suitable for temperatures ranging from -160-450 ℃; Widely used for measuring liquid levels that are highly corrosive, flammable, explosive, toxic, highly radioactive, agitated, and contaminated; All models can choose the Dingyou magnetic alarm switch to achieve automatic control or alarm of high and low liquid levels; Each model can be equipped with a 4-20mADC liquid level transmitter for remote centralized measurement and control. Oil measuring magnetic flap level gauge, anti-corrosion level gauge, remote alarm magnetic flap level gauge, product applicable objects: The CYUHZ series magnetic flip plate (column) level gauge can be widely used in various industries such as petroleum, chemical, oil field, medicine, food, and wine to measure and display the liquid level, liquid level, and two different medium interfaces of various storage tanks, tanks, tanks, reaction tanks, fermentation tanks, liquids in oil fields, liquefied gas, liquid hydrogen, strong acid and alkali liquids, weak acid and alkali liquids, power plant boiler steam drums, high and low pressure heaters, deaerators, drain tanks, return water tanks, high and low pressure heaters, condensers, evaporators, and other pressure vessels compatible with 1Cr8NiTi, 304+PTEE (polytetrafluoroethylene), 316L, PVC, PP liquid media. There are multiple installation forms for you to choose from to meet the requirements of different occasions and environments. 7、 Additional function options: Magnetic limit switch: Normally open: merge above the alarm point Normally closed: disconnected above the alarm point Switch capacity: 250VAC1A (resistive) 250VAC0.3A (inductive) Switch lifespan: 100000 cycles Liquid level transmitter: Output current: 4-20mADC Resolution: ± 1- ± 10mm Load resistance: 500 Ω (when powered by 24VDC) Transmission distance:>3000m Working power supply: 16-30VDC Intelligent liquid level transmitter: Output current: 4-20ADC Resolution: 0.2mm Load resistance: 500 Ω (when powered by 24VDC) Transmission distance:>3000m Working power supply: 16-30VDC Form of jacket: Steam jacket and water circulation jacket are a layer of cylinder added to the main pipe of the liquid level gauge for the circulation of steam, circulating water or thermal oil. Vacuum jacket is a layer of vacuum cylinder added outside the main tube of the liquid level gauge to insulate the measured medium from the outside. Double layered jacket generally refers to adding a vacuum jacket outside the steam tracing jacket. The electric heat tracing system wraps an electric heat tracing strip around the main pipe of the liquid level gauge to heat the medium.
|