Welcome Customer !

Membership

Help

Jiangsu Huayun Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Jiangsu Huayun Instrument Co., Ltd

  • E-mail

    1702662999@qq.com

  • Phone

    18915186518

  • Address

    No. 99 Tongtai Avenue, Industrial Concentration Zone, Jinhu County, Jiangsu Province

Contact Now

Lime level gauge

NegotiableUpdate on 08/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The MKSD500 series RF admittance level gauge is a novel level measuring instrument that uses advanced RF admittance technology to overcome the defect of capacitive level gauges that cannot eliminate the influence of conductive hanging materials. The instrument has reliable operation and is suitable for almost all industrial sites. Instruments also have the characteristics of easy installation, maintenance free, and low price, and are widely used in industrial fields such as petroleum, chemical, metallurgical, pharmaceutical, power, food, paper, etc. Manufacturer's price: starting from 548.00~66600.00 yuan, batch size 1 unit. Specification parameters: customized processing. The brand is Huayun model HC-CYW, with a detection range of 20M and a measurement accuracy of 0.2% of the range. The working voltage is DC24V, and the display resolution is 0.03% of the actual range. The working frequency is 1 second (HZ), and the working temperature is -45 ℃~+85 ℃ (℃). The applicable range is liquid level and material level measurement. Overview: The important difference between this product and capacitive technology is the diversity of measurement and anti hanging material technology. The diversity of measurement quantities for RF admittance level switches lies not only in measuring capacitance, but also in measuring the comprehensive quantity of capacitance, resistance, and inductance, making the measurement more comprehensive and accurate. Anti hanging material technology involves adding a shielding electrode between the measuring electrode and the electrode to protect the measuring electrode from hanging materials. Radio frequency admittance solves the problem of material adhesion and has higher system stability compared to other similar products. Even under extremely harsh on-site conditions, it can work reliably without being affected by hanging materials, temperature, pressure, material density, humidity, or even changes in material chemical properties. Powered by 220V or 24VDC, it has been widely used due to its reliable performance and easy installation. Measurement principle: Shooting .....

Product Details



The MKSD500 series RF admittance level gauge is a novel level measuring instrument that uses advanced RF admittance technology to overcome the defect of capacitive level gauges that cannot eliminate the influence of conductive hanging materials. The instrument has reliable operation and is suitable for almost all industrial sites. Instruments also have the characteristics of easy installation, maintenance free, and low price, and are widely used in industrial fields such as petroleum, chemical, metallurgical, pharmaceutical, power, food, paper, etc.
生石灰物位计|雷达生石灰物位计厂家|价格选型
Manufacturer's price:
price ¥ 548.00-66600.00 yuan
Starting from batch ≥1 tower
Specification parameters:
Customized processing correct brand Vauen model HC-CYW
Detection range 20M measurement accuracy 0.2% of the measuring range working voltage DC24V
display resolution 0.03% of the actual range Operating Frequency 1 second (Hz) operation temperature -45℃~+85℃(℃)
scope of application Liquid level and material level measurement

summary:
The important difference between this product and capacitive technology lies in the diversity of measurements and anti hanging material technology. The diversity of measurement quantities for RF admittance level switches lies not only in measuring capacitance, but also in measuring the comprehensive quantity of capacitance, resistance, and inductance, making the measurement more comprehensive and accurate. Anti hanging material technology involves adding a shielding electrode between the measuring electrode and the electrode to protect the measuring electrode from hanging materials.
Radio frequency admittance solves the problem of material adhesion and has higher system stability compared to other similar products. Even under extremely harsh on-site conditions, it can work reliably without being affected by hanging materials, temperature, pressure, material density, humidity, or even changes in material chemical properties. Powered by 220V or 24VDC, it has been widely used due to its reliable performance and easy installation.


Measurement principle:
Radio frequency admittance is a new level control technology developed from capacitive technology, which is anti hanging, more reliable, accurate, and widely applicable. It is an upgrade of capacitive level technology. The so-called radio frequency admittance refers to the reciprocal of impedance in electricity, which is composed of resistive, capacitive, and inductive components. Radio frequency is the spectrum of high-frequency radio waves, so radio frequency admittance can be understood as measuring admittance using high-frequency radio waves. When the instrument is working, the sensor of the instrument forms an admittance value with the tank wall and the measured medium. When the level changes, the admittance value changes accordingly. The circuit unit converts the measured admittance value into a level signal output to achieve level measurement.
Working principle of Jiangsu RF admittance level meter:
The level switch consists of a sensor unit and an electronic unit. The sensor unit mainly consists of three parts: measuring probe, shielding electrode, and grounding terminal. The height of the material is reflected by the change in admittance between the probe and the container wall. When the material reaches the switch operating point, the electronic unit reacts, drives the relay to operate, and outputs a switch signal. Shielding electrodes can prevent misoperation signals caused by hanging materials on the electrodes. The relay only outputs a signal when the material truly reaches the set point.


Application medium:
1. Power plant: coal pile, raw coal bin, fuel bin, reservoir, exhaust gas purification tank, bin pump, ash silo, fuel tank, etc;
2. Oilfield: crude oil or finished oil storage tanks, three-phase separators, settling tanks, sewage tanks and oil-water interfaces, drilling mud tanks, etc;
3. Chemical industry: crude oil distillation tower, raw materials and intermediate silos, reaction tanks, ammonia tanks, solid silos, separators, etc;
4. Metallurgy: ore silo, ore crusher, raw material silo, auxiliary material silo, blast furnace, alumina powder silo, electrolytic cell buffer tank, etc;
5. Cement: stone silo, raw material silo, cement silo, coal powder silo, slag storage silo, etc;
6. Water treatment: reservoirs, sewage tanks, water treatment tanks, sedimentation tanks, deep wells, drinking water networks, etc;
7. Paper making: raw material warehouse, storage tower, drying drum, chemical material storage warehouse, etc;
8. Other industries include quarries, food, pharmaceuticals, environmental protection, shipbuilding, etc.


Performance characteristics:
1. Strong universality: It can measure liquid and material levels, meet the measurement requirements of different temperatures, pressures, and media, with high measurement temperatures up to 800 ℃ and high pressures up to 5Mpa, and can be applied to harsh environments such as corrosion and impact.
2. Anti hanging material: The unique circuit design and sensor structure enable its measurement to be unaffected by sensor hanging material, without the need for regular cleaning, avoiding false measurements.
3. Maintenance free: There are no movable parts during the measurement process, and there is no mechanical component damage issue, so no maintenance is required.
4. Anti interference: contact measurement, strong anti-interference ability, can overcome the influence of steam, foam and agitation on measurement.
5. Accurate and reliable: Diversified measurement quantities make measurements more accurate, measurement is not affected by environmental changes, high stability, and long service life.

Technical indicators:
1. Power supply: 220VAC ± 50VAC 50/60HZ (standard);
110VAC ± 25VAC 50/60HZ (standard); 24VAC ± 5VAC (optional);
2. Output: DPDT relay (double pole double throw);
3. Output capacity: 220VAC 5A;
4. Environmental temperature: -40 ℃ to 70 ℃;
5. Medium temperature: -100 ℃ to 800 ℃;
6. Resolution:<0.5PF;
7. Repeatability:<1mm (conductive medium); <10mm (insulation medium);
8. Response time:<0.5s;
9. Delay: 1-50s;
10. High and low level alarm: on-site can be set to HLFS (high level alarm mode) or LLFS (low level alarm mode) Spark protection (for sensors): built-in spark protection circuit;
11. Electrical interface: M20 * 1.5;
12. Cable: The dedicated connection cable between the split electronic unit and the sensor is standard 5m and 50m long;
13. Process connection: NPT thread installation (standard); Flange installation (optional);
14. Shell protection: IP66;
15. Explosion proof: Exd [ia] iallct4.


Selection and installation:
1) When measuring non-conductive media, it can be installed horizontally or vertically. If vertical installation is required, the probe length should be at least 6 inches longer than the control position.
2) When measuring conductive liquids, mud or interface detection, it can be installed horizontally and vertically. The contact position between the probe and the material is the alarm position.
3) When measuring powder and granular materials, they can be installed horizontally or vertically, but when the probe passes through the container, the protective electrode should be 2 inches longer than the thickness of the accumulated material on the container wall.
If required by the user, we can provide corrosion-resistant probes made of Teflon or Kyanr material (connected with coated flanges).


Installation method.
1. Measure the liquid level of bucket shaped tanks using rod or cable probes:
Note: The probe rod or cable should avoid the opening and feeding port, and the probe rod or cable should be parallel to the warehouse wall. The distance between the warehouse wall should be greater than 200mm.
2. Measure the liquid level of a horizontal tank using a coaxial probe:
Note: Non barrel shaped tanks and non-metallic wall tanks can be measured using coaxial probes.
3. Measure the liquid level of a spherical tank using a connector:
Note: Spherical tanks and other irregularly shaped tanks can be measured using connectors.
4. Use heavy-duty cable to probe the material level of powder or fine particle silos:
Note: The probe should avoid the feeding port. When the warehouse wall is made of concrete, the grounding terminal of the sensor housing should be reliably connected to the concrete reinforcement with a wire.
The protective sleeve of Taiyuan Lime Powder Level Gauge, with a length of 150mmo, is made stronger, more practical, and more reliable by any other material with a constant value rather than adhesive accumulation. Due to the fact that the current cannot move at the same potential, it is measured by the circuit. The MKSD500 RF admittance level gauge uses the American Princo anti adhesion circuit design to detect the real level while making the electronic circuit parameters more reliable. The study also uses insulators with a diameter of up to 10mm and surrounding air as dielectric materials to produce L863WC steel cables and L864C ceramics. The high temperature of L863WC steel cables and L864C ceramics is affected by the correct setting of dielectric constant sensitivity, which will affect the correct change of sensor output. We mainly adopt advanced design and production technology from abroad and establish sensitivity settings (circuits). Comparison with reference standards


Basic parameters
texture of material:

Shell: Aluminum

Measurement range:

Solid 0-15 meters

Measurement accuracy:

±3mm ﹪

Working voltage:

Two wire system (DC24V)/four wire system (DC24V/AC220V) v

Working environment temperature:

-40~250 mPa

Work form:

Antenna: single cable or single pole antenna, flange or threaded installation

Power:

Operating frequency: 500MHz-1.8GHz w

Medium temperature:

-40~250 mPa

Density:

Applicable medium: solid powder application: solid powder measurement, complex process conditions

Output signal:

(4-20) mA/HART power supply: two-wire system (DC24V)/four wire system (DC24V/AC220V)

Temperature:

-40~250

Pressure:

-0.1~4 mPa

***Large short-circuit current:

4-20 mA

***High open circuit voltage:

24 v

detailed description

Customized processing: Yes Type: Guided Wave Radar Level Gauge
Measurement range: Solid 0~15 meters Measurement accuracy: ± 3mm
Current signal: 4~20 (mA) Power supply: Two wire system (DC24V)/Four wire system (DC24V/AC220V)
Operating frequency: 500MHz-1.8GHz