Welcome Customer !

Membership

Help

Jiangsu Huayun Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Jiangsu Huayun Instrument Co., Ltd

  • E-mail

    1702662999@qq.com

  • Phone

    18915186518

  • Address

    No. 99 Tongtai Avenue, Industrial Concentration Zone, Jinhu County, Jiangsu Province

Contact Now

Liquefied gas level gauge

NegotiableUpdate on 08/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

One Overview of HS-2000 Liquefied Gas Level Gauge HS-2000 Intelligent Liquefied Gas Level Gauge When measuring, the ultrasonic probe is installed directly below the outer wall (bottom) of the measured container, without the need for holes, easy to install, and does not affect on-site production. It can measure various toxic substances and pure liquids in high-temperature and high-pressure sealed containers. The instrument adopts explosion-proof design to meet explosion-proof requirements. The TK-LW external mounted ultrasonic level gauge adopts a sensor external attachment and non-contact measurement method with the measured liquid, achieving true complete isolation measurement. By combining the company's proprietary technologies such as variable frequency ultrasound, digital signal processing, pattern recognition, and database processing, the impact of tank walls and external interference has been overcome; At the same time, automatic parameter calibration can be performed to ensure that the instrument is not affected by changes in medium temperature and composition. It is particularly suitable for measuring the liquid level of various toxic substances, strong acids, strong alkalis, and various pure liquids in closed containers, without opening holes, using hot work, and achieving non-stop installation of the tank body. At the same time, the instrument can output standard communication signals such as (4-20) mA to output measurement results to automation control systems such as DCS. Working principle: TK-LW intelligent external mounted ultrasonic level gauge adopts the principle of sonar (ultrasonic) echo distance measurement. The measuring probe emits and receives sonar signals, penetrates the container wall to form echoes in the liquid, and achieves distance measurement. The side (or diagonally below) probe is a calibration probe that can continuously or periodically emit calibration sound waves to achieve sound velocity calibration and ensure high-precision and stable measurement. Especially in the liquid level measurement of a large range of spherical tanks, fuzzy processing theory and frequency conversion ultrasonic technology are adopted to establish .....

Product Details



One Overview of HS-2000 Liquefied Gas Level Gauge

When measuring the HS-2000 intelligent liquefied gas level gauge, the ultrasonic probe is installed directly below (at the bottom) the outer wall of the tested container, without the need for holes, easy to install, and does not affect on-site production. It can measure various toxic substances and pure liquids in high-temperature and high-pressure sealed containers. The instrument adopts explosion-proof design to meet explosion-proof requirements. The TK-LW external mounted ultrasonic level gauge adopts a sensor external attachment and non-contact measurement method with the measured liquid, achieving true complete isolation measurement. By combining the company's proprietary technologies such as variable frequency ultrasound, digital signal processing, pattern recognition, and database processing, the impact of tank walls and external interference has been overcome; At the same time, automatic parameter calibration can be performed to ensure that the instrument is not affected by changes in medium temperature and composition. It is particularly suitable for measuring the liquid level of various toxic substances, strong acids, strong alkalis, and various pure liquids in closed containers, without opening holes, using hot work, and achieving non-stop installation of the tank body. At the same time, the instrument can output standard communication signals such as (4-20) mA to output measurement results to automation control systems such as DCS.
working principle:
The TK-LW intelligent external mounted ultrasonic level gauge adopts the principle of sonar (ultrasonic) echo distance measurement. The measuring probe emits and receives sonar signals, penetrates the container wall to form echoes in the liquid, and achieves distance measurement. The side (or diagonally below) probe is a calibration probe that can continuously or periodically emit calibration sound waves to achieve sound velocity calibration and ensure high-precision and stable measurement. Especially in the liquid level measurement of large range spherical tanks, fuzzy processing theory and variable frequency ultrasound technology are used to establish advantages in large range liquid level measurement.
液化气液位计|磁翻板液液化气液位计|价格选型
Manufacturer's price:

price ¥ 500.00~56700.00 yuan
Starting from batch ≥1 tower

Specification parameters:
Customized processing correct brand Vauen model JS-201,UHZ
measuring range 300~20000mm measurement accuracy 10~20mm Measurement tube material 304, 316, PP, etc
scope of application Liquid measurement


II Characteristics of HS-2000 Liquefied Gas Level Gauge

(1) The probe is external, without the need to open holes in the tested container, truly achieving non-contact measurement. It is suitable for measuring the liquid level of toxic, volatile, flammable, explosive, highly corrosive and other liquid media in various closed containers.
(2) The instrument has no mechanical moving parts and a long lifespan. No corrosion, no pollution, and wide usage area.
(3) The instrument is equipped with ASIC (Intelligent Ultrasonic Specific Hardware Integrated Circuit), which makes the instrument small in size, stable and reliable in measurement results, and suitable for various tested liquids and containers. It is easy to install on site and does not require complex on-site calibration.
(4) The instrument is equipped with various calibration functions such as automatic temperature correction and automatic fixed distance calibration, making the measurement results more accurate and reliable.
(5) The instrument is fully functional, with RS-485 interface and 4-20mA interface.

III Main performance parameters of HS-2000 liquefied gas level gauge

Range: 3m 5m 10m 20m 30m
Measurement error: 1 ‰ (Tank wall thickness, unstable pressure and temperature may affect accuracy)
Display resolution: 1mm
Migration volume: ± 10 m
Current output: 4-20mA, * * * large load 750 Ω
Communication: RS-485
Power supply: DC 24V ± 15%, 10W
Humidity: 15% RH to 100% RH
Shell protection: IP65
Explosion proof mark: ExdIICT6
Material: Cast aluminum
Display: Wide temperature LCD display with 6-digit digital display
Ultrasonic probe operating environment temperature: -50~220 ℃
Technical Requirements for Liquefied Petroleum Gas Liquid Level Gauge

Measurement range: 0-5000mm
Accuracy: ± 10mm ± 16mm
Nominal pressure: 2.5MPa
Medium density: ≥ 0.7g/cm3 (special requirements can reach 0.45g/cm3)
Medium temperature: -20 to+350 ℃
Medium viscosity: ≤ 2.0Pa.s
Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm
Alarm and remote transmission device: technical parameters are the same as UHZ-25 series

Guidelines for selecting liquefied petroleum gas level gauges:

1. The nominal pressure of anti-corrosion type should be ≤ 1.0MPa.

2. There is a certain blind spot in the liquid level gauge, so compensation for the blind spot value should be added when reading the liquid level height (when our liquid level gauge leaves the factory, the zero position of the scale has been moved to the actual value).

3. The measuring range of the liquid level gauge should not exceed 5 meters, otherwise it will affect the stability, reliability, and fastness of the liquid level gauge.

4. Install the connecting flange, and refer to the commonly used protrusion size reference (HG21592-97) for manufacturing this level gauge at the factory.

Installation, use, and maintenance of liquefied petroleum gas level gauges:

1. The protective conduit and main conduit of the liquid level gauge must be kept vertical

2. The connecting rod cannot bend and must be inserted straight

3. After installation, the flip column of the monitor needs to be guided once with magnetic steel to display white above zero and red below zero.

底装顶装式磁翻板液位计

Selection Table for Liquefied Gas Level Gauge Products:


Model
UHZ-517

Structural characteristics

Liquid receiving material

measuring range
(mm)

Applicable medium conditions

Flange connection (mm)

Weight (kg)

temperature
(℃)

pressure
(Mpa)

density
g/cm3

Viscosity
(Pa.s)

DN

PN

basic
weight

lengthening
basic
weight

C10

Standard type

1Cr18Ni
9Ti0Cr18Ni9
(304)

300-
8000

-20
+150

0-2.45

0.5-2

≤0.04

25

1.0
1.6

6

5

C11

High pressure

300-
8000

-20
+150

2.45-9.6

0.5-2

≤0.04

25

2.5
4.0

6

6

C12

High temperature type
High pressure

300-
8000

-20
+350

2.45-9.6

0.5-2

≤0.04

25

6.3
1.0

6

6

C13

Low temperature model
(Frost proof type)

300-
3500

>-40

0-2.45

0.5-2

≤0.04

25

1.6
2.5

6

7.5

C14

Liquid ammonia, liquid
Fossil oil and gas
specialized

300-
15000

-20
+150

0-2.45

0.45-0.7

≤0.05

25

2.5

6.5

6

C15

anti-corrosive

00Cr17Ni14Mo2
(316L)

300-
8000

-20
+150

0-2.45

0.5-2

≤0.04

25

1.6

6

5

C16

Anti corrosion type(
PP outer layer glass
Fiberglass steel

PP

300-
5000

20
+100

0-0.6

0.5-2

≤0.04

32

1.6

3

3

C17

Anti corrosion type(
PVC outer layer
Fiberglass reinforced plastic

U-PVC

300-
5000

20
+60

0-0.5

0.5-2

≤0.04

32

1.6

3

3

C18

Anticorrosive type

ABS

300-
5000

-20
+120

0-0.6

0.5-2

≤0.04

32

1.0

3

3

C19

Anti corrosion type(
Stainless steel interior
Lined with PP

PP

300-
15000

-20
+100

0-1.0

0.5-2

≤0.04

25

1.6

4

5

C20

Anticorrosive type

PE

300-
5000

20
+40

0-0.6

0.5-2

≤0.04

25

1.6

6

7

C21

Steam jacket
Heating type

1Cr18Ni9Ti

300-
15000

-20
+150

0-2.45

0.5-2

≤0.05

32

1.6

6

8

C22

high viscosity
Medium type

0Cr18Ni9
(304)

300-
15000

-20
+150

0-2.45

0.5-2

≤0.05

32

1.6

6

5

C23

Food Specialty
Usage type

1Cr18Ni9Ti

300-
15000

-20
+150

0-1.6

0.5-2

≤0.05

50

1.6

7

5

Instrument configuration instructions:

□□

Content of supporting instruments and accessories

O

Blind flange, without drain valve

L

Bottom of the liquid level gauge is equipped with a drain valve

O

No liquid level alarm switch

H

High level alarm switch AK-3 type, with memory function, failure to troubleshoot, signal not eliminated

L

Low level alarm switch AK-4 type, with memory function, failure to troubleshoot, signal not eliminated

B

High and low alarm switches are fully equipped, with memory function for AK-3 and AK-4 models

G

High level alarm switch, regional alarm AK-1 type

One DF-1 type conversion amplifier is attached
One PF113A socket




High power relay (single point: one, double point: two) PF083A socket

D

Low level alarm switch, regional alarm AK-1 type

Q

High and low alarm switches are fully equipped, with two AK-1 regional alarms

S

Integrated high and low position alarm switch, regional alarm AK-2 type

O

No liquid level control switch

H

Upper limit control switch, single point spring CK-1 type

L

Lower limit control switch, single point spring CK-1 type

B

Fully equipped with upper and lower limit control switches, single point dry spring CK-1 type two sets

W

Integrated upper and lower limit control switches, dual point spring CK-2 type

T

Upper limit control switch, Hall sensor CK-3 type

L

Lower limit control switch, Hall sensor CK-4 type

E

Fully equipped with upper and lower limit control switches, Hall sensor CK-3 type two sets

C

Integrated upper and lower limit control switches, Hall sensor CK-4 type

O

No remote transmission transmitter device

R

Equipped with LB type bundled transmitter, output two-wire 4-20mADC

S

Static pressure remote transmitter, (URS-100) output two-wire 4-20mADC

O

Ordinary waterproof type

B

Inherent safety type IB Ⅱ CT4, can be equipped with Zener safety barrier or IS4041 Ex isolation barrier

Bd

Explosion proof type d Ⅱ CT4

O

Not suitable for remote transmission display instrument

A

Digital and light column display adjustment alarm XGTH-510 (vertical)

B

Digital and light column display adjustment alarm XGTA-810 (horizontal)

C

Digital display adjustment alarm XMTA-810 (horizontal)

E

Double column liquid level display instrument XGH-202 (vertical)

D

Intelligent liquid level/capacity (weight) display regulator XMT-620 (horizontal)

-□□□□

Measurement range (mm)

-□□

Medium density (g/cm3)

-

D

Open pressure container

Work pressure (MPa)

The process measurement of liquefied gas level gauge has no blind spots, with eye-catching display, intuitive reading, and a large measurement range. Especially in the on-site indication section, as it does not come into direct contact with liquid media, its superiority is even more evident for high temperature, high pressure, high viscosity, toxic and harmful, and highly corrosive media. Therefore, it is more reliable, safe, progressiveness and practical than the traditional glass tube and plate level gauge.