Welcome Customer !

Membership

Help

Hebei Zhuangke Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Hebei Zhuangke Instrument Co., Ltd

  • E-mail

    326561707@qq.com

  • Phone

    13613218527

  • Address

    Zhao County, Shijiazhuang City, Hebei Province

Contact Now

Manufacturer of high and low temperature wet heat test chamber for drugs

NegotiableUpdate on 01/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The drug high and low temperature wet heat test chamber manufacturer is suitable for stability testing of drugs and new drugs in pharmaceutical enterprises, meeting the technical conditions of accelerated testing, long-term testing, and high and low temperature wet heat testing specified in GMP principles.
Product Details

Manufacturer of high and low temperature wet heat test chamber for drugs


Drug high and low temperature damp heat test chamberInstallation site:

  • The ground is flat and well ventilated

  • There is no strong vibration around the device

  • There is no strong electromagnetic field around the equipment

  • There are no flammable, explosive, corrosive substances or dust around the equipment

  • Leave appropriate space for use and maintenance around the equipment


Drug high and low temperature damp heat test chamberProhibited:

  • Testing and storage of radioactive material samples;

  • Testing and storage of highly toxic substance samples;

  • The testing or storage of samples that may produce the above-mentioned substances or objects during the testing or storage process.

  • Testing and storage of samples of flammable, explosive, and volatile substances;

  • Testing and storage of corrosive substance samples;

  • Testing or storage of biological samples;

Power supply conditions

Power supply: AC220V ± 10%, 50 Hz, protection ground wire grounding resistance less than 4 Ω;

ambient temperature

5℃~35℃。

Humidification water

Using purified water, distilled water, and deionized water.

ambient humidity

≤85%RH


The freezing problem in the walk-in high and low temperature laboratory? We can solve it through the following multiple levels:

1. Check if the body is sealed, and if there is a leakage area, seal it with silicone rubber.

2. Install a heating device on the internal air conditioning evaporator and set the defrosting time.

3. The defrost setting when the refrigeration unit resumes using the high temperature caused by the refrigeration compressor. In high and low temperature laboratory experiments, if the temperature of the test object is lower than the moisture content of the environmental test chamber, condensation conditions will occur. The key conditions for condensing water in a walk-in high and low temperature laboratory are as follows:

1. The working temperature exceeds 30 ° C and the operating environment humidity exceeds 60% RH.

2. The environmental humidity ranges from low to high, and the temperature ranges from low to high.

3. The temperature changes from low to high.

Manufacturer of high and low temperature wet heat test chamber for drugs