Welcome Customer !

Membership

Help

Hebei Zhuangke Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Multi box stability test box for drugs

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The comprehensive drug multi box stability test box is an equipment that integrates temperature, humidity, light, and ultraviolet illumination testing conditions. It can simultaneously meet the requirements of long-term testing, accelerated testing, high-temperature testing, and strong light irradiation testing specified in the pharmacopoeia. It is the preferred solution for pharmaceutical companies to conduct drug stability testing.

Product Details

comprehensiveMulti box stability test box for drugsIt is a device that integrates temperature, humidity, lighting, and ultraviolet illumination testing conditions, and can simultaneously meet the requirements of long-term testing, accelerated testing, high-temperature testing, and strong light irradiation testing specified in the pharmacopoeia. It is the preferred solution for pharmaceutical companies to conduct drug stability testing.

comprehensiveMulti box stability test box for drugsProduct Features

  • The main technical parameters of the equipment are superior to the technical requirements stipulated by GMP, and also meet the relevant requirements stipulated by ICH and FDA.

  • The selection of this series can be based on specific test conditions and site requirements.

  • Adopting a multi-channel touch screen temperature and humidity control instrument, it integrates functions such as temperature, humidity, lighting, UV, printing, USB export of recorded data, communication, cumulative timing, alarm prompts, etc.

  • Equipped with temperature and humidity deviation, power outage and other SMS alarms, wireless or wired RS485 communication interface, facilitating centralized monitoring of equipment and management of multiple devices.

● Adopting multi-channel touch screen temperature and humidity control instrument

● Temperature and humidity deviation, power outage and other SMS and phone alarm prompts

● Third level permissions and audit tracking

Wireless or wired RS485 communication interface

● Electronic data storage and export

Real time printing

● Accumulated timing

1. Normally, a constant temperature and humidity incubator should be placed at room temperature. For laboratories that do not have this condition, appropriate air conditioning must be provided.

2. Adhere to the professional management and maintenance of dedicated personnel, and units with conditions should periodically send dedicated personnel to the supplier's factory for training and learning, in order to gain more professional experience and ability in maintenance and repair.

3. Regularly clean the condenser every 3 months, ensuring not only the inlet pressure and temperature, but also the corresponding flow rate. Regularly clean and scale the inside of the condenser to obtain its continuous heat transfer performance.

4. Regularly clean the evaporator: Due to the different cleanliness levels of the test samples, a lot of small particles such as dust will accumulate on the evaporator under forced air circulation, so regular cleaning should be carried out.

5. Cleaning and balancing the circulating fan and condenser fan is similar to cleaning the evaporator. Due to the different working environments of the test chamber, a lot of small particles such as dust will accumulate on the circulating fan and condenser fan, and they should be cleaned regularly.

6. Waterway and humidifier cleaning: If the waterway is not smooth and the humidifier scales, it is easy for the humidifier to dry and burn, which may damage the humidifier. Therefore, it is necessary to regularly clean the waterway and humidifier.

7. Persist in setting the temperature near the ambient temperature after each experiment, work for about 30 minutes, then cut off the power and clean the inner wall of the studio.

8. When the product is not in use for a long time, it should be powered on regularly every half month for at least 1 hour.