Welcome Customer !

Membership

Help

AGC Instruments Ireland Limited Beijing Representative Office
Custom manufacturer

Main Products:

pharmamach>Products

AGC Instruments Ireland Limited Beijing Representative Office

  • E-mail

  • Phone

    13911644071

  • Address

    6G, Yaoyan Building, Jiulong Mountain Villa, Xihongmen, Daxing District, Beijing

Contact Now

NovaCHROM 1000 high-purity gas analysis instrument

NegotiableUpdate on 04/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Description: The AGC NovaCHROM 1000 high-purity gas analyzer has been a pioneer in the field of high-sensitivity gas chromatography, especially in the analysis of high-purity gas impurities, for many years. It adopts advanced technology to provide our customers with accurate results and meets the needs of easy operation and maintenance. The interactive touch screen uses an easy-to-use interface as a guide, making training simple. This also allows operators to apply it freely and ensures that the NovaCHROM1000 helium ion gas chromatograph can provide you with assurance at any time.
Product Details

AGC NovaCHROM 1000High purity gas analysis instrumentThe NovaCHROM1000 helium ion chromatograph is developed based on the successful AGC100 series chromatography, and is the first chromatography in the NovaCHROM series.

AGC NovaCHROM 1000High purity gas analysis instrumentIn the field of high-sensitivity gas chromatography, especially in the analysis of high-purity gas impurities, it has been a work of many years. It adopts advanced technology to provide our customers with accurate results and meets the needs of easy operation and maintenance. The interactive touch screen uses an easy-to-use interface as a guide, making training simple. This also allows operators to apply it freely and ensures that the AGC NovaCHROM 1000 new helium ion gas chromatograph can provide you with assurance at any time.

1Compliant with standards:

GB/T 8979-2008 "High Purity Nitrogen" GB/T 14599-2008 "High Purity Oxygen"
GB/T 4844.3-1995 "High Purity Helium" GB/T 4842-2006 "Argon"
GB/T 7445-1995 "Pure Hydrogen, High Purity Hydrogen, Ultra Pure Hydrogen" GB/T 17873-1999 "Pure Neon"
GB/T 5829-1995 "Krypton" GB/T 5828-1995 "Xenon"
HG/T 3633-1999 "Pure Methane" GB 10621-2006 "Food Additives - Liquid Carbon Dioxide"

GB/T 16942-2009 "Gas Hydrogen for Electronic Industry" GB/T 16943-2009 "Gas Helium for Electronic Industry"
GB/T 16944-2009 "Gas Nitrogen for Electronic Industry" GB/T 16945-2009 "Gas Argon for Electronic Industry"
GB/T 14604-2009 "Gas Oxygen for Electronic Industry" GB/T 14600-2009 "Gas Argon Nitrogen Oxide for Electronic Industry"
GB/T 14601-2009 "High purity ammonia gas for electronic industry" GB/T 14602-93 "Hydrogen chloride gas for electronic industry"
GB/T 14603-2009 "Gas BF3 for Electronic Industry" GB/T 18994-2003 "Gas high-purity chlorine for Electronic Industry"
GB/T 14851-93 "Phosphine gas for electronic industry" GB/T 17874-1999 "Boron trichloride gas for electronic industry"
GB/T 15909-2009 "Gas Silane for Electronic Industry" GB/T 21287-2007 "Gas Nitrogen Trifluoride for Electronic Industry"

IITechnical specifications:

1. Detection limit

AGC NovaCHROM1000Detection limit of helium ion gas chromatograph(ppb

component

H2

O2

N2

CH4

CO

CO2

C2H2

N2O

Ne

Kr

Xe

detection limit

5

10

10

1

20

10

5

10

20

10

10

2. Performance indicators:

detector

DIDHelium ion detector

repetitiveness

0.5% of range

precision

0.5% of scale

response time

0.5Second(90%

Column box temperature

ambient temperature5~450

Multi column box

have

temperature-programmed

10step

heating rate

0.1~40/min(increment0.1)

Cooldown

300~50℃(5min

EPCElectronic flow control

have

power supply

115/220V50/60Hz2300W

weight

30kg(depending on configuration)

size

572mmW)×508mmH)×559mm(D)

3. Carrier gas purifier:

Purifier type

Renewable Purifier

Purification level

can be5.5levelHePurified to6.5Level or even higher.

Cleared impurities:

H2O, O2, CO, CO2,THC, H2, N2 (Each item is less than1 ppb)

Suggested temperature for use:

350°C

Zui High Operating Temperature:

450°C

The maximum operating pressure:

10 bar

Zui high flow rate:

500 ml

Standard installation interface:

1/8” VCR

Power requirements:

110/220/240 V 50/60 Hz , 500 VA

Net weight:

9 kg

4. Workstation performance:

Model:

AGC Trend-Vision

manufactor:

IrelandAGCInstrument Co., Ltd

output:

Zui has many16road independent4-20mAoutput

Zui Duo21A tall one/Low alarm passive relay electric shock

Communication interface:

350°C

resolution

24Bit resolution

input range

1V

Heavy linearity

±0.002% of full scale

Integral sensitivity

1μv•sec

System compatibility

• Windows XP ®

• Windows Vista ®

• Windows 7 ®

• Windows 8 ®

• Windows 10 ®

3、 Main features:

  • Equipped with DID helium ion detector

  • Sensitivity at ppb level

  • Fast response time ≤ 0.5 seconds (90%)

  • 6.5-inch color LCD large touch screen

  • Long term stability and sensitivity

  • *Application of automation

  • Electropolished stainless steel tube

  • Integrated configuration alarm system

  • EPC electronic pressure control

  • Independent chromatographic column box with separate temperature control function

  • Integrated Comprehensive Diagnostic System

  • Controlled through Trend vision workstation software *

  • Added links for RS-232 and RS-485, as well as two USB interfaces

  • Pull down front control panel for easy maintenance and operation

  • 19 inch rack mounted online installation

4、 Technical advantages:

  • The core components of a chromatograph----The DID HFADD FID TCD detector from AGC company is based on the independent research and development of AGC company in Ireland. It has strong performance, high sensitivity and stability, and is the choice for analyzing low content impurities in high-purity gas;

  • *Parallel connection of dual detectors----AGC company has developed dual detectors for parallel use, equipped with two independent detectors. Their temperature control system and operation are both independent detectors, which can be connected in series or parallel.

  • Gas path system of chromatograph----The unique center cutting and blowback system technology can complete the analysis and detection of multiple complex components at once;

  • The software system of the chromatograph----Trend Vision, specially developed for AGC chromatography, can not only complete test reports, automatically analyze/store data, automatically draw spectra, reverse control gas chromatography, adjust retention time and various cutting actions, but also control up to 4 analytical instruments simultaneously;

    Carrier gas purification system----The AGC 75-802 carrier gas purifier is a renewable purifier that can purify 5N grade gas to above 7.5N. The ultra-high purity carrier gas gives the AGC high-purity gas chromatograph higher sensitivity;
  • Carrier gas switching device----The configuration of CGDP-01 carrier gas switching device can simultaneously carry two bottles of carrier gas, avoiding the entry of polluted gas when switching gas sources after the carrier gas is used. The configuration of the carrier gas switching device ensures higher work efficiency and analysis quality of AGC gas chromatography;

  • AGC Instrument Co., Ltd. in Ireland is a professional company that produces and customizes high-purity gas analysis gas chromatographs. We have strong analytical methods and technical advantages in the field of high-purity gas analysis. AGC has hundreds of high-purity gas chromatography analyzers in the Chinese market, and our large customer base and stable product quality give us an advantage in high-purity gas analysis!

5、 Chromatogram

6、 Can be equipped with detectors

The NovaChromium series includes:

NovaCHROM 1000 equipped with helium ion discharge detector (DID)

NovaCHROM 2000 is equipped with an argon discharge detector (ADD)

NovaCHROM 3000 equipped with flame ionization detector (FID)

NovaCHROM 4000 equipped with Thermal Conductivity Detector (TCD)

NovaCHROM 5000 equipped with flame photometric detector (FPD)

7、 Optional online cabinet installation

AGC NovaCHROM 1000Combined with the powerful TrendVision workstation software from AGC company, it makes the operation more convenient.

About more DIDHelium ion gas chromatographInformation, please be direct.