1、 Overview of oil flow meter:
The oil flow meter is a lightweight volumetric flow instrument with pointer display, word wheel cumulative counting device, and zero return device. The oil flow meter is widely used in liquid flow control in various industrial fields, suitable for measuring various types of liquids such as crude oil, diesel, gasoline, etc. It has the characteristics of large range, high accuracy, and easy use and maintenance. At the same time, the diesel flow meter can also meet the liquid flow measurement in various fields such as petroleum, chemical, pharmaceutical, food, metallurgy, power, transportation, etc.
The AK-LC series elliptical gear flowmeter (oil flowmeter) is a volumetric flowmeter that measures the total flow rate of liquid flowing through pipelines. This instrument has high measurement accuracy, is less affected by liquid viscosity, and does not require a straight pipe section to be installed in front of the meter. It is widely used for cumulative flow measurement of high viscosity media.

wholesale price:
| price |
¥ 200.00~56430.00 yuan
|
| Starting from batch | ≥1 tower |
Specification and model:
| Customized processing | correct | brand | Vauen | model | LC |
| type | Positive displacement flowmeter | measuring range | 0.6-350(m3/h) | accuracy class | 0.5, 0.2 |
| Nominal Diameter | 8-250(mm) | Applicable Medium | oil | Working pressure | 1.6, 2.5, 4.0, 6.3 (MPa) |
| operation temperature | -30+70(℃) |
|
1、 Overview We have an independent product design and manufacturing system that can provide a variety of materials, calibers, and connection methods, as well as matching converters, display instruments, and flow computers. |
Typical applications:
The elliptical gear flowmeter is mainly used to measure high viscosity media, and the product is widely used in industries such as petroleum, petrochemical, natural gas, chemical, paper, etc,
Used for measuring small pipe diameters in small flow metering.
Main advantages:
The caliber ranges from 10 to 150mm;
There are multiple options for shell materials to choose from: aluminum, stainless steel, and medium to high pressure stainless steel PPS、 Bronze, etc;
There are various bearing materials to choose from: ceramic, bronze, Hastelloy, carbide PPS、 Stainless steel, etc;
◆ Material of shaft: 316 stainless steel;
The materials for O-rings include VITON, fluororubber, stainless steel, and Teflon for selection;
The range ratio is 10:1, and * * * can reach up to 50:1;
The accuracy is two types: ± 1% and ± 0.5%, with a repeatability of ± 0.03%;
During installation, the straight pipe section requires 5D+3D and a filter needs to be installed;
◆ Viscosity * * * can reach up to 1000 000CP;
The pressure level can reach up to 551 bar;
◆ Temperature resistance level * * * up to -10~400 ℃;
2、 Technical performance characteristics
1. Technical performance of elliptical gear flowmeter
|
model |
caliber |
***Small traffic |
***Large traffic |
accuracy class |
Work pressure (Mpa) |
|
LC—10 |
10 |
0.04 |
0.4 |
0.5,0.2 |
1.6,2.5,4.0,6.4 |
|
LC—15 |
15 |
0.16 |
1.5 |
||
|
LC—20 |
20 |
0.3 |
3 |
||
|
LC—25 |
25 |
0.6 |
6 |
||
|
LC—40 |
40 |
1.5 |
15 |
||
|
LC—50 |
50 |
2.4 |
24 |
||
|
LC-65 |
65 |
3 |
30 |
||
|
LC—80 |
80 |
6 |
60 |
||
|
LC—100 |
100 |
10 |
100 |
||
|
LC—150 |
150 |
12 |
120 |
2. Characteristics of elliptical gear flowmeter
Flow measurement is independent of the flow state of the fluid, as the elliptical gear flowmeter relies on the pressure head of the measured medium to drive the elliptical gear to rotate for measurement. The higher the viscosity of the medium, the smaller the amount of leakage from the gear and measuring space gap. Therefore, the larger the viscosity of the measured medium, the smaller the leakage error, and the more advantageous it is for measurement. The elliptical gear flowmeter has high measurement accuracy and is suitable for measuring the flow rate of high viscosity media, but it is not suitable for fluids containing solid particles (solid particles can jam the gear, making it impossible to measure the flow rate). If gas is mixed in the measured liquid medium, it can also cause measurement errors. Elliptical gear flowmeter is a type of volumetric flowmeter used for precise continuous or intermittent measurement of liquid flow or instantaneous flow in pipelines. It is particularly suitable for flow measurement of high viscosity media such as heavy oil, polyvinyl alcohol, resin, etc.
3、 Working principle
The working principle of the elliptical gear flowmeter is that the measuring part of the elliptical gear flowmeter is mainly composed of two meshing elliptical gears and their housing (measuring chamber), as shown in the following figure:
Working principle diagram of elliptical gear flowmeter
4、 Installation and use precautions of elliptical gear flowmeter
The elliptical gear flowmeter should be cleaned before installation. If the liquid contains solid particles, a filter must be installed upstream of the pipeline; If it contains gas, an exhaust device should be installed. The elliptical gear flowmeter does not have certain requirements for the front and rear straight pipe sections. It can be installed horizontally or vertically. During installation, the elliptical gear rotation axis of the flowmeter should be parallel to the ground.
Installment and use
1. The installation direction of the instrument should be consistent with the direction of the arrow on the instrument housing and the direction of liquid flow. The installation position should be easy to read (see the figure below)
2. Instruments should be installed at room temperature as much as possible, and should not be installed in environments with harmful gases or strong thermal radiation to prevent damage to the counter part of the instrument.
3. The elliptical gear shaft in the instrument should be installed in a horizontal position as much as possible, that is, the dial should be installed in a vertical position (division "0") and should be on top to reduce friction between the elliptical gear and the housing and reduce wear of the parts. Due to different installation positions, in order to facilitate reading, the counter (meter head) can be rotated 90 ° or 180 ° (see the figure below).
4. Before installing the instrument, the pipeline must be thoroughly cleaned. In the entire pipeline system, if there is no strict filtering device, a filter should be installed in front of the instrument to prevent impurities from entering the instrument.
5. The instrument should be installed at the outlet end of the pump, and the flow control valve should be installed downstream of the instrument. When using, first open the upstream shut-off valve, and then slowly open the downstream flow control or shut-off valve. Sudden opening or closing is strictly prohibited.
The elliptical gear flowmeter installed correctly according to the requirements can ensure sufficient accuracy during use, and the accuracy of the cumulative value can usually reach level 0.5, making it a relatively accurate flow measuring instrument. However, if the flow rate of the measured medium is too low during use, the impact of instrument leakage errors will become prominent, and sufficient measurement accuracy cannot be guaranteed. Therefore, different models and specifications of elliptical gear flow meters have an allowable value for small flow rates, and measurement accuracy can only be guaranteed when the actual measured flow rate is greater than the lower limit flow rate allowable value. Secondly, when using an elliptical gear flowmeter, it is important to note that the temperature of the measured medium should not be too high, otherwise it will not only increase measurement errors but also have the potential to cause gear jamming. Therefore, the elliptical gear flowmeter is used within the specified temperature range of the instrument. After long-term use, the internal gears of the elliptical gear flowmeter will be corroded and worn, which will affect the measurement accuracy. Therefore, it is important to regularly observe and dismantle for inspection. If conditions permit, calibration should be carried out regularly.
2、 Measurement principle of oil flow meter

Under the action of the pressure difference between the liquid at the inlet and outlet of the flowmeter measurement chamber, a pair of elliptical gears continuously rotate on the bearings and discharge the liquid. By measuring the number of revolutions of the elliptical gears, the total value of the liquid flowing through the instrument can be determined. If the volume Q discharged after one revolution of the elliptical gear and the number of rotations of the elliptical gear per unit time is N, then the volume of liquid flowing through during that time is NQ.
3、 Product features of oil flow meter
AK-LC-A type cast iron elliptical gear oil flowmeter is widely used for measuring various oil products and non corrosive liquid media of cast iron.
AK-LC-E type cast steel elliptical gear oil flow meter, used for measuring high-pressure and low corrosive media
AK-LC-B stainless steel elliptical gear oil flow meter, widely used for measuring highly corrosive liquid media such as acids, bases, salts, and organic compounds
Performance parameters of oil flow meter
Oil flow meter connection method: flange connection: DN10~DN200
Installation method of oil flow meter: horizontal, vertical
Accuracy level of oil flow meter: ordinary type 0.5 level, high-precision 0.2 level
Oil flow meter pressure resistance: ordinary type 1.6MPa, high-pressure type 3.2MPa
Oil flow meter temperature resistance: ordinary type<120 ℃, high-pressure type<200 ℃
Oil flow meter made of materials such as cast iron, cast steel, stainless steel, etc
Rotating components: aluminum alloy, stainless steel, etc
Optional oil filter can be installed
The pipeline of the oil flow meter should be cleaned before installation. If the liquid contains solid particles, a filter must be installed upstream of the pipeline;
The elliptical oil flow meter does not have certain requirements for the front and rear straight pipe sections. It can be installed horizontally or vertically. During installation, the elliptical gear rotation axis of the flowmeter should be parallel to the ground
|
Header display: |
Pointer accumulation, zero return, pulse output, 4-20mA output, LCD display, communication output |
|
Instrument model: |
LC-11 display, 12 display with signal, 13 signal output, H return to zero, N high viscosity, T high temperature, Y LCD display |
|
Measurement medium: |
Liquids and various oils |
|
Caliber specification: |
10---200 |
|
Flow measurement range: |
0.04-340 m3/h |
|
Measurement accuracy: |
Level 0.5, Level 0.2 |
|
Temperature of the tested medium: |
-20 ℃ -100 ℃, * * * high+200 ℃ |
|
working pressure: |
1.6MPa 2.5MPa 6.4MPa |
|
Output signal: |
Pulse, 4-20mA RS485 |
|
Communication type: |
RS485 |
|
Power Supply: |
DC12V ---DC24V |
|
Installation method: |
Flange connection, threaded connection |
|
Explosion proof grade: |
ExiaIIBT4 |
|
Protection level: |
IP65 |
The oil flow meter installed correctly according to the requirements can ensure sufficient accuracy during use, and the accuracy of the cumulative value can usually reach level 0.5, making it a relatively accurate flow measuring instrument. However, if the flow rate of the measured medium is too low during use, the impact of instrument leakage errors will become prominent, and sufficient measurement accuracy cannot be guaranteed. Therefore, different models and specifications of diesel flow meters have an allowable value for * * * small usage flow rate. Only when the actual measured flow rate is greater than the lower limit flow rate allowable value, can the measurement accuracy be guaranteed. Secondly, when using an oil flow meter, it is important to note that the temperature of the measured medium should not be too high, otherwise it will not only increase measurement errors but also have the potential to cause gear jamming. Therefore, the oil flow meter is used within the temperature range specified by the instrument. Measurement range and working pressure of oil flow meter
|
model |
AK-LC-A cast iron |
AK-LC-E cast steel |
AK-LC-B stainless steel |
||||
|
nominal pressure Mpa |
1.0 1.6 |
2.5 4.0 6.4 |
1.0 1.6 |
||||
|
Viscosity of the tested liquid |
2 — 200 mPa.s |
||||||
|
Temperature of the tested liquid |
-20℃~+100℃ |
||||||
|
Flow range m ³ h |
|||||||
|
model accuracy class |
AK-LC-A cast iron |
AK-LC-E cast steel |
AK-LC-B stainless steel |
||||
|
Nominal diameter (DNmm) |
0.5 |
0.2 |
0.5 |
0.2 |
0.5 |
0.2 |
|
|
10 |
0.04~0.4 |
0.1~0.4 |
0.04~0.4 |
0.1~0.4 |
0.1~0.5 |
0.1~0.5 |
|
|
15 |
0.25~1.5 |
0.3~1.5 |
0.25~1.5 |
0.3~1.5 |
0.3~1.5 |
0.3~1.5 |
|
|
20 |
0.5~3 |
0.6~3 |
0.5~3 |
0.6~3 |
0.6~3 |
0.6~3 |
|
|
25 |
1~6 |
1.2~6 |
1~6 |
1.2~6 |
1.2~6 |
1.2~6 |
|
|
40 |
2.5~15 |
3~15 |
2.5~15 |
3~15 |
3~15 |
3~15 |
|
|
50 |
4~24 |
4.8~24 |
4~24 |
4.8~24 |
4.8~24 |
4.8~24 |
|
|
65 |
5~40 |
8~40 |
5~40 |
8~40 |
8~40 |
8~40 |
|
|
80 |
10~60 |
12~60 |
10~60 |
12~60 |
12~60 |
12~60 |
|
|
100 |
16~100 |
20~100 |
16~100 |
20~100 |
20~100 |
20~100 |
|
|
150 |
32~190 |
38~190 |
32~190 |
38~190 |
38~190 |
38~190 |
|
|
200 |
34~340 |
68~340 |
34~340 |
68~340 |
68~340 |
68~340 |
|
|
|
|
|
|
|
|
|
|
Oil flow meter selection code
|
AOKE |
|
Aoke Company's business logo |
|||||||
|
Basic model |
LC |
|
Basic models of elliptical gear flowmeter |
||||||
|
Caliber selection |
-□□ |
|
Diameter size |
||||||
|
Material selection |
-A |
|
cast iron |
||||||
|
|
-E |
|
cast steel |
||||||
|
|
-B |
|
stainless steel |
||||||
|
output signal |
-2 |
|
No signal output |
||||||
|
|
-3 |
|
Pulse DV24V power supply |
||||||
|
|
-4 |
|
4-20mA DV24V power supply |
||||||
|
Zeroing function |
-N |
|
No reset function |
||||||
|
|
-F |
|
Zeroing function |
||||||
|
filter |
-N |
|
No Filter |
||||||
|
|
-G |
|
Including filter |
||||||
|
Traffic selection |
(□~□) |
|
Flow range |
||||||
Instructions for using electronic header
1、 Function
1.1 Display Function
Accumulated flow and instantaneous flow.
1.2 Operation
Press the "" and "F" keys simultaneously to display the dot coefficient on the LCD screen. (10% flow coefficient), then press the "F" key in sequence, and the LCD displays 2, 3, and 4. Among them, 2 is the 50% flow coefficient, 3 is the 100% flow coefficient, and 4 is the 4-20mA * * large flow rate.
1.3 Coefficient per point of LCD display
The upper line represents the number of pulses per second at that point, while the lower line represents the number of pulses per cubic meter at that point.
1.4 Power Supply
The on-site indication is 3.6V, explosion-proof lithium battery. Remote transmission 24V (4-20mA) lead out wiring.
Red is a positive number, blue is a negative number.
2、 Instructions for using electronic meter heads (integrators).
2.1 "" is the displacement key, "" is the set key.
2.2 Press the "+F" key to clear the accumulation (reset).
2.3 Set the coefficient to 1-4, then press the "" and "F" keys to reset.
Display: Q is the traffic. The instantaneous flow rate on the LCD is m3/h. Accumulated traffic m3 for the following behavior
2.4 Error correction. (Calculation of coefficients for each point)
New coefficient=original coefficient x (1+error)
Error=(table indication value - standard value)/standard value
3、 Common faults
3.1 LCD: Instantaneous and cumulative display but not moving:
a) Card meter, flow meter needs to be cleaned.
b) The calculator crashes, power off and restart. This situation is rare.
3.2 LCD not displaying: power disconnected.
3.3 Suddenly, the error is too large and the impeller is damaged. The impeller needs to be replaced (which can be purchased from the manufacturer).