Welcome Customer !

Membership

Help

Jiangsu Huayun Instrument Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Jiangsu Huayun Instrument Co., Ltd

  • E-mail

    1702662999@qq.com

  • Phone

    18915186518

  • Address

    No. 99 Tongtai Avenue, Industrial Concentration Zone, Jinhu County, Jiangsu Province

Contact Now

Sodium hydroxide level gauge

NegotiableUpdate on 08/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The specialized level gauge for sodium hydroxide storage tanks uses a magnetic float as the measuring element and a magnetic steel driven flip column display, without the need for energy. Suitable for various environments ranging from low temperature to high temperature, vacuum to high pressure, etc. It is an ideal liquid level measurement product for industries such as petroleum and chemical. The dedicated level gauge for sodium hydroxide storage tanks uses a level gauge controller, and its contact capacity is designed for resistive loads. If non resistive or high efficiency loads are used, intermediate relays must be used for conversion. For situations where liquid media contain suspended impurities and magnetic substances, it is not advisable to use a side mounted magnetic flap level gauge with a sinking cylinder distance. Users must be aware of this parameter. This parameter is related to the density of the medium. According to the principle of buoyancy, the length of the float component is related to the density of the medium. Therefore, when selecting and designing, it is necessary to consider that different media have different sinking distances. Manufacturer's price: starting from 500.00~39800.00 yuan per batch, 1 unit. Specification parameters: customized processing. The brand is Huayun model UHZ-519, with a measurement range of 0-10M and a measurement accuracy of 1. The measuring tube material is stainless steel, PTFE, PVC, and the applicable range is level measurement. The magnetic flap level gauge is a device specially developed for level measurement based on the principles of magnetism and Archimedes' law of buoyancy, combined with the characteristics of mechanical transmission. The side mounted magnetic flap level gauge uses a magnetic float as the measuring element and a magnetic steel driven flip column display, without the need for energy. Suitable for various environments ranging from low temperature to high temperature, vacuum to high pressure, etc. It is an ideal liquid level measurement product for industries such as petroleum and chemical. Structure principle of sodium hydroxide level gauge: developed based on buoyancy principle and magnetic coupling effect. When the liquid level in the tested container rises or falls, the float in the main tube of the level gauge also rises or falls accordingly .....

Product Details



The specialized level gauge for sodium hydroxide storage tanks uses a magnetic float as the measuring element and a magnetic steel driven flip column display, without the need for energy. Suitable for various environments ranging from low temperature to high temperature, vacuum to high pressure, etc. It is an ideal liquid level measurement product for industries such as petroleum and chemical.
The dedicated level gauge for sodium hydroxide storage tanks uses a level gauge controller, and its contact capacity is designed for resistive loads. If non resistive or high efficiency loads are used, intermediate relays must be used for conversion. For situations where liquid media contain suspended impurities and magnetic substances, it is not advisable to use the "sinking distance" parameter of the side mounted magnetic flap level gauge. Users must be aware of this parameter. This parameter is related to the density of the medium. According to the principle of buoyancy, the length of the float component is related to the density of the medium. Therefore, when selecting and designing, it is necessary to consider that different media have different sinking distances.

氢氧化钠液位计|磁翻板液氢氧化钠液位计厂家|价格选型
Manufacturer's price:

price ¥ 500.00~39800.00 yuan
Starting from batch ≥1 tower

Specification parameters:

Customized processing correct brand Vauen model UHZ-519
measuring range 0-10M measurement accuracy 1 Measurement tube material Stainless steel, PTFE, pvc
scope of application Level measurement


The magnetic flap level gauge is a device specially developed for level measurement based on the principles of magnetism, Archimedes' law of buoyancy, and other principles combined with the characteristics of mechanical transmission. The side mounted magnetic flap level gauge uses a magnetic float as the measuring element and a magnetic steel driven flip column display, without the need for energy. Suitable for various environments ranging from low temperature to high temperature, vacuum to high pressure, etc. It is an ideal liquid level measurement product for industries such as petroleum and chemical.
Structure principle of sodium hydroxide level gauge:
Developed based on the principle of buoyancy and magnetic coupling. When the liquid level in the tested container rises or falls, the float in the main tube of the level gauge also rises or falls accordingly. The magnetic steel inside the float is transmitted to the on-site indicator through magnetic coupling, driving the red and white flip columns to flip 180 degrees. When the liquid level rises, the flip column changes from white to red, and when the liquid level drops, the flip column changes from red to white. The red and white boundary of the indicator is the actual height of the medium liquid level in the container, thus achieving the indication of the liquid level.
The significant feature is that the liquid medium is completely isolated from the indicator, making it very safe, reliable, and durable in any situation. Moreover, various models of liquid level gauges are equipped with liquid level alarms and control switches, which can achieve upper and lower limit over limit alarms, control, or interlocking of liquid levels or boundaries; Equipped with a static pressure level transmitter or a dry spring resistance level transmitter, the liquid level and boundary signals can be converted into a two-wire 4-20mADC standard signal, enabling remote indication, detection, recording, and control. This series of magnetic flap level gauges can be widely used for level measurement and control in various industries such as power, petroleum, chemical metallurgy, environmental protection, shipbuilding, construction, and food production processes.
Overview of Sodium Hydroxide Level Gauge Products:
It can be used for medium level detection of various towers, tanks, spherical containers, boilers and other equipment. It can achieve high sealing, leak prevention, and adapt to liquid level measurement under high pressure, high temperature, and corrosive conditions, with reliable safety. It compensates for the shortcomings of glass plate (tube) liquid level gauges, such as unclear indication and easy breakage, and is not affected by high and low temperature fluctuations. It does not require the combination of multiple sets of liquid level gauges.
The entire measurement process has no blind spots, with clear display, intuitive readings, and a large measurement range. Especially in the on-site indication section, as it does not come into direct contact with liquid media, its superiority is even more evident for high temperature, high pressure, high viscosity, toxic and harmful, and highly corrosive media. Therefore, it is more reliable, safe, progressiveness and practical than the traditional glass tube and plate level gauge.


Technical parameters of sodium hydroxide level gauge:
1. Measurement range: 300-15000mm
2. Accuracy: ± 10mm, ± 16mm
3. Flip column diameter: 10mm, 16mm
4. Working pressure: ≤ 2.5Mpa (additional juice can be set for pressures above 2.5Mpa) Anti corrosion type ≤ 0.6Mpa
5. Medium density (g/cm3): 0.5-2
6. Medium temperature: -20 ℃+250 ℃ (special requirements can reach 450 ℃)
7. Medium viscosity: ≤ 0.4Pa • S. For media with high viscosity or media that are prone to agglomeration at low temperatures, heating jacket liquid level juice can be selected according to user requirements.
8. Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm
9. Follow speed: ≤ 0.08m/s
10. Installation methods: side mounted, top mounted, bottom mounted
11. Protection level: IP65
12. Explosion proof level: ib Ⅱ CT4 (intrinsic safety type), d Ⅱ BT4 (explosion-proof type)
13. Transmission mode: 4-20mA or switch quantity

14. Connecting flanges: HG20592-20635-97 flange standard. If other flange standards (such as GB, ANSI, DIN, etc.) are used, please indicate when placing an order. For the connection flange of high-pressure side mounted magnetic level gauge, HG20595-97 neck butt welding connection flange DN25, PN6.0 or PNl0Mpa shall be used, and the sealing surface shall be raised or convex. If there are special requirements, they can be specified when ordering.

The selection table for sodium hydroxide level gauge is as follows:


Common
Enduring * * * high work pressure: normal pressure (below 1.0Mpa)
***High operating temperature: 80 ℃
Measurement range: 0-12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
Anticorrosive type
Undertaking * * * high work pressure: below 10Mpa
***High operating temperature: 80 ℃
Measurement range: 0-12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
Heat tracing type
Enduring * * * high work pressure: below 10Mpa
***High operating temperature: 200 ℃
Measurement range: 0-12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
Frost proof type
Enduring * * * high work pressure: below 10Mpa
***High operating temperature: 80 ℃
Measurement range: 0-12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
High temperature type
Enduring * * * high work pressure: below 10Mpa
***High operating temperature: 200-450 ℃
Measurement range: 0-12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
High pressure
Enduring * * * high work pressure: exceeding 10MPa (below 31 MPa)
***High operating temperature: 200 ℃
Measurement range: 0-6m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
High temperature and high pressure type
Enduring * * * high work pressure: exceeding 10MPa (below 20 MPa)
***High operating temperature: 200-450 ℃
Measurement range: 0-6m
Measurement of medium density:
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
Explosion proof type
Undertaking * * * high work pressure: below 10Mpa
***High operating temperature: 120 ℃
Measurement range: 0-12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
Top mounted type
Enduring * * * high work pressure: 1.6MPa
***High operating temperature: 200 ℃
Measurement range: 0-12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Default installation direction for display panel: forward facing away from the flange
Installation form Material Nominal diameter nominal pressure D D1 D2 n d f b
Side stainless steel 20 4.0 105 75 56 4 14 2 16
ABS 20 10 105 75 56 4 14 2 16
Top mounted stainless steel 200 2.5 360 310 274 12 26 3 32
ABS 200 0.6 320 280 274 8 8 3 32
Main technical indicators of specialized level gauge for sodium hydroxide storage tank
Installation form and content Side mounted Top mounted
Installation spacing
(Measurement range)
stainless steel 500~5000(mm) 500-2500(mm)
ABS、PP-R 500~4000(mm)
Working pressure 0.6,1.6,2.5,4.0MPa 0.6,1.6,2.5MPa
Medium density >0. 6g/c >0.76g/c
Flange connection stainless steel Flange 20-40 (DN20 PN1.0-4.0)
(GB9119-88)
Flange 200-25 (DN200 PN1.6)
(GB9119-88)
ABS Flange 20-10 (DN20 PN1.0)
(GB9119-88)
Flange 200-6 (DN200 PN0.6)
(GB9119-88)
Main material ICr18Ni9Ti, ABS, PP-R (working pressure 0.6MPa)
medium temperature -40-100 ℃ (ABS, PP-R: -40-80 ℃)
ambient temperature -40~+70℃
Indication error ±100mm
Viscosity ≤1st(10-4/s)
Upper and lower limits
Switching output
1. Control sensitivity: 10mm
2. Output contact capacity: AC220V 2A
3. Contact life: 5 × 104 times
4. Explosion proof feature: iaIICT4 intrinsic safety type
Electric remote transmission
Continuous Display
1. Accuracy: ± 1.5%
2. Output load: 750 Ω
3. Output signal: 0-10mA output, 220V AC power supply
4-20mA output, 24V DC two-wire system
4. Explosion proof feature: iaIICT4 intrinsic safety type
characteristic
① No leakage, corrosion resistance, safe and reliable use;
② Simple structure, minimal maintenance, and long service life;
③ The liquid level is easy to observe, especially suitable for remote monitoring, with gas red and liquid green, clear at a glance;
④ The center distance can be of any size and is not limited by the length of glass plates or quartz tubes.
Technical parameters of specialized level gauge for sodium hydroxide storage tank
● Normal working conditions
Environmental temperature -25 ℃~70 ℃
Relative humidity ranging from 5% to 100% (including condensation and direct humidity)
Atmospheric pressure ranging from 86MPa to 108MPa
Measurement range: 500mm to 3000mm, graded
Measurement accuracy: Float type indicator ± 20mm
Flip column indicator ± 20mm
● Working pressure 1MPa, 1.6MPa, 2.5MPa, 4MPa, 6.3MPa
Medium density ranging from 0.5g/cm3 to 1.8g/cm3
● Medium viscosity ≤ 0.05Pa · s
Medium temperature -25~80 ℃, (high temperature type 0~200 ℃), (patented high temperature type 0~450 ℃)
Tracking speed ≤ 0.8m/s
Contact medium material 1Cr18Ni9Ti polytetrafluoroethylene
Measurement range (m)
0~0.5
0.5~2
2~3
Measurement accuracy (%)
±2
±1.5
±1

Control point error ± 10mm
● Return error shall not exceed the basic error
The repeatability error shall not exceed the basic error
The contact capacity of the switch control point is AC or DC220V; 1A (pure resistive load)
● Small spacing between control points (mm) 60
● Shell protection level IP54
XMT-124D digital display instrument (can set upper and lower limit alarms and outputs)
4-20mA signal) with external dimensions of 160 × 80 × 180
Explosion proof grade d Ⅱ BT4

key word: Liquid level measurement and control, interface measurement and control
Measurement range [L]:
(Center distance between upper and lower flanges)
User proposed
Connection flange specifications: DN20 PN1.0RF or requested by the user
Liquid receiving material:
321 or 304 stainless steel
316l stainless steel
pvc plastic
Stainless steel lined with PTFE
321 or 304 stainless steel
Or user specified
Medium density [g/cm3]:
(Proposed by the user)
≥0.53
Working temperature [℃]: ≤80℃,≤150℃,≤350℃
Work pressure [MPa]: 0~4.0MPa
Output signal: -----------
Applicable voltage/current: -----------

Basic type
measuring range
H=500 800 1700 3000 6000... 10000
Users can choose freely within the range of 0-10000mm
Indication accuracy
+-5mm
Medium density
>0.45g/cm3
Poor medium density and quality
>0.15g/cm3
operation temperature
-196~120 degrees Celsius 120~300 degrees Celsius (high temperature type)
Viscosity
< 1ST (10-4 square meters/S)
Connecting flange
(1) When PN2, 5, 4.0MP, the flange is JB/T82.2-94, DN25PN4.0 movable convex flange.
(2) When PN6.3, 10.0, 16.0MPa, the flange is T82.2~94, and DN25 fixed flange.
(3) PVC material flange JB/T82.1-94, PN1.0MPa, DN20.
Other flange standards (such as HGJ, GB, ANSI, etc.) should be specified by the design department and the user.
liquid level alarm
output form
CONTACT CAPACITY
working life
Alarm accuracy
power supply
ambient temperature
Three normally open and three normally closed switch signals
220VAC 2A
>10 to the power of five
+-5mm
24VDC 220VAC 50HZ
-40~60 degrees Celsius
Liquid level remote transmission device
Remote transmission range
0~10000mm (optional)
Long distance transmission * * *
3Km
accuracy
+-10.0mm
load resistance
250 amps (excluding wire resistance of 200 amps)
return difference
+-10.0mm
power supply
24V。DC,220V。 AC,50HZ
output signal
4~20mADC
ambient temperature
-40~60 degrees Celsius
B outlet connector
Internal thread M20 * 1.5
Selection of specialized level gauges for sodium hydroxide storage tanks:
Basic model
work
pressure
alarm
to configure
Transmitter
to configure
explosion-proof
require
flange
orifice
measure
range
special
type
Expressing meaning
XT-UHZ-52
—□
—□
—□
—□
/□
Type spectrum
P
***High working pressure (MPa)
O
No alarm
B
Equipped with alarm system
O
No transmitter
M
Equipped with MY type transmitter
J
Equipped with JY type transmitter
O
No explosion-proof requirements
d
Explosion proof type
D1
DN20
D2
DN25
L
Flange center distance (mm)
Z
Jacket type