1、 Introduction:
The sulfuric acid storage tank level transmitter adopts advanced microprocessing technology and digital communication technology. In addition to all the conventional intelligent functions, it also has a series of enhanced features, such as zero point automatic adjustment, remote on-site control parameter viewing and adjustment, control parameter password locking, etc. At the same time, remote parameter setting, remote control, self diagnosis and other functions are performed through the fieldbus HART protocol.

2、 Fieldbus communication capability:
The fieldbus of the sulfuric acid storage tank level transmitter is a bidirectional digital communication system, which is an innovative technology for configuring instrument control systems and also a promising replacement product for the widely used standard 4-20mA analog communication in field instruments.
Provide two fieldbus modes, FOUNDATION? Fieldbus low-voltage mode and PROFIBUS PA equipment are used to achieve collaborative work between AstraZeneca and other suppliers. In terms of software, the HYA210 series uses two AI function blocks to calculate differential pressure and static pressure, thereby achieving flexible instrument configuration.
3、 Small and lightweight design:
Due to the use of ASIC amplifier design, the packaging of the sulfuric acid storage tank level transmitter has been reduced, and the membrane box structure and flange have been miniaturized. As a result, the weight of this model has been reduced to half of the original model. ASIC design not only reduces the number of parts, but also improves the reliability of the amplifier.
4、 Application of sulfuric acid storage tank level transmitter product:
Single flange remote differential pressure transmitter is used to measure the flow rate, liquid level, density, and pressure of gases, liquids, and vapors, and then convert them into 4-20mADC current signals for output. HYA210A/220A can also communicate with each other through the BRAN controller, CENTUM CS/μ XL, or HART275 controller for setting and monitoring.
5、 Main features of HY3851LT/1151LT sulfuric acid storage tank level transmitter:
1. Super measurement performance, used for pressure, differential pressure, liquid level, and flow measurement;
2. Digital accuracy:+(-) 0.2%;
3. Simulation accuracy:+(-) 0.75%+(-) 0.1% F.S;
4. Full performance:+(-) 0.25F.S;
5. Stability: 0.25% for 60 months;
6. Range ratio: 100:1;
7. Measurement rate: 0.2S;
8. Compact (2.4kg) all stainless steel flange, easy to install;
9. Process connection is compatible with other products to achieve measurement;
10. The world's sensors with H-alloy sheath (patented technology) have achieved excellent cold and hot stability;
11. Intelligent transmitter using 16 bit computer;
12. Standard 4-20mA, with digital signal based on HART protocol, remote control;
13. Support the upgrade to fieldbus and field control based technologies.
6、 Technical parameters of HY3851LT/1151LT sulfuric acid storage tank level transmitter:
1. Output signal: 4-20mA DC two-wire system (analog) Two wire system 4-20mA DC signal is superimposed with a digital signal, and the user selects linear or square root output. (Intelligent)
2. Power supply: 12-45V.DC;
3. Load characteristics:
Power supply impact:<0.005% output range/V;
Load impact: When the power supply is stable, there is no load impact;
Measurement accuracy: ± 0.1% of the calibration range, ± 0.2. The standard accuracy is ± 0.2%. If other accuracies are selected, please indicate them when ordering and selecting;
Range ratio: 10:1 or 100:1;
Damping: usually adjustable between 0.1 and 16 seconds, the time constant increases when filled with inert fluid or with a remote transmission device;
Start time:<2 seconds, no preheating required.
4. Working environment: ambient temperature -29~93 ℃ (analog amplifier);
-29~75 ℃ (digital/intelligent amplifier);
-29-65 ℃ (with display header);
The environmental humidity is 0-95%.
5. Protection features: IP65 protection capability;
6. Explosion proof type: Explosion proof Exd II BT4-6; Intrinsically safe Exia II CT5.
7. Static pressure influence: Zero position error: ± 0.5% * * * Large range limit, corrected by zeroing for 32MPa under pipeline pressure.
8. Electromagnetic radiation impact: 0.05% * * * large range value, accepted radiation frequency of 27-500MHz, test field strength of 3V/m.
9. Indicator (%): LCD digital display accuracy ± 0.2%.
10. Vibration effect: ± 0.05%/g when vibrating at 200Hz in any direction.
11. Installation position: The diaphragm is not installed vertically, which may result in a zero point error of less than 0.24KPa, but it can be corrected by adjusting the zero point.
12. Weight: 3.9Kg (excluding accessories).
7、 Single flange differential pressure transmitter is suitable for the following media applications:
1. Viscous media at high temperatures;
2. Medium that is prone to crystallization;
3. Settling media with solid particles or suspended solids;
4. Strong corrosive or highly toxic media;
5. Can eliminate the occurrence of pressure pipe leakage and pollution of the surrounding environment; It can avoid the tedious work of frequently replenishing isolation fluid due to the instability of measurement signals when using isolation fluid;
6. Continuous measurement of interface and density;
7. The remote transmission device can avoid the mixing of different instantaneous media, thus enabling the measurement results to truly reflect the actual situation of process changes;
8. Places with high hygiene and cleanliness requirements;
9. In the production of food, beverage, and pharmaceutical industries, not only is it required that the contact area of the transmitter with the medium meet hygiene standards, but it should also be easy to rinse to prevent cross contamination of different batches of media.
8、 HY3851LT/1151LT sulfuric acid storage tank level transmitter selection list:

|
HY3851LT/1151LT |
Sulfuric acid storage tank level transmitter (* * * maximum working pressure 2.5MPa) |
|||||||||
|
|
4 |
0-4~40KPa |
||||||||
|
5 |
0-40~250KPa |
|||||||||
|
6 |
0-0.16~1.0MPa |
|||||||||
|
|
code |
output |
||||||||
|
N |
Ordinary analog type: (output: 4-20mA) |
|||||||||
|
G |
Conventional intelligent type: (output: 4-20mA) |
|||||||||
|
S |
Standard intelligent type: (Output: 4-20mA with HART bus protocol) |
|||||||||
|
Z |
Digital intelligent type: (Output: 4-20mA fully digital sensor, built-in communication keyboard) |
|||||||||
|
|
code |
Nominal diameter size (mm) |
Insertion tube length (mm) |
High pressure side diaphragm material |
||||||
|
A0 |
80 |
flat |
316LSST |
|||||||
|
A2 |
80 |
50 |
316LSST |
|||||||
|
A4 |
80 |
100 |
316LSST |
|||||||
|
A6 |
80 |
150 |
316LSST |
|||||||
|
B0 |
100 |
flat |
316LSST |
|||||||
|
B2 |
100 |
50 |
316LSST |
|||||||
|
B4 |
100 |
100 |
316LSST |
|||||||
|
B6 |
100 |
150 |
316LSST |
|||||||
|
C0 |
80 |
flat |
Ha Shi C-276 |
|||||||
|
C2 |
80 |
50 |
Ha Shi C-276 |
|||||||
|
C4 |
80 |
100 |
Ha Shi C-276 |
|||||||
|
C6 |
80 |
150 |
Ha Shi C-276 |
|||||||
|
D0 |
100 |
flat |
Ha Shi C-276 |
|||||||
|
D2 |
100 |
50 |
Ha Shi C-276 |
|||||||
|
D4 |
100 |
100 |
Ha Shi C-276 |
|||||||
|
D6 |
100 |
150 |
Ha Shi C-276 |
|||||||
|
E0 |
80 |
flat |
tantalum |
|||||||
|
F0 |
100 |
flat |
tantalum |
|||||||
|
|
code |
mounting flange |
|
|||||||
|
A |
3〞150lb |
Galvanized carbon steel |
||||||||
|
B |
4〞150lb |
|||||||||
|
C |
3〞300lb |
|||||||||
|
D |
4〞300lb |
|||||||||
|
|
code |
Structural materials |
||||||||
|
Flanges and fittings |
Exhaust/Drain Valve |
Isolation Diaphragm |
Fill with liquid |
|||||||
|
22 |
316 stainless steel |
316 stainless steel |
316 stainless steel |
silicone oil |
||||||
|
23 |
316 stainless steel |
316 stainless steel |
Hastelloy C |
|||||||
|
24 |
316 stainless steel |
316 stainless steel |
Monel |
|||||||
|
25 |
316 stainless steel |
316 stainless steel |
tantalum |
|||||||
|
33 |
Hastelloy C |
Hastelloy C |
Hastelloy C |
|||||||
|
35 |
Hastelloy C |
Hastelloy C |
tantalum |
|||||||
|
|
code |
option |
||||||||
|
M1 |
0-100% linear indicator table |
|||||||||
|
M2 |
LED digital display table |
|||||||||
|
M3 |
LCD display |
|||||||||
|
C0 |
1/2-14NPT taper pipe internal thread joint |
|||||||||
|
C1 |
1/2-14NPT pressure joint rear welded pressure pipe with a diameter of 14 |
|||||||||
|
C2 |
T-shaped threaded joint M20 × 1.5 |
|||||||||
|
d |
Explosion proof type d Ⅱ BT4 |
|||||||||
|
i |
Intrinsic safety type IA Ⅱ CT |
|||||||||
9、 Instructions for ordering and selecting sulfuric acid storage tank level transmitters:
1. The model can be determined according to the selection specification table as needed.
2. The numbers and symbols in the selection specification table must be filled in clearly and accurately.
3. If there is positive or negative migration, the migration amount value must be indicated.
4. If a differential pressure transmitter needs to be equipped with a three valve group, it needs to be specified separately.
5. When selecting a remote transmitter, it should also be determined according to different remote flange selection tables as needed.
6. If the remote transmitter is to be used in vacuum and high temperature environments, it should be specially marked when ordering.
7. The materials for contact medium O-ring seals include rubber and fluororubber.
8. Unless otherwise specified, the filling fluid at the factory is silicone oil.