Phone
15921165535
-
Address
No. 418 Huajing Road, Shanzhong Science and Technology Park, Waigaoqiao Free Trade Zone, Pudong New Area, Shanghai
Duzhi Instrument (Shanghai) Co., Ltd
15921165535
No. 418 Huajing Road, Shanzhong Science and Technology Park, Waigaoqiao Free Trade Zone, Pudong New Area, Shanghai
The Jig 500 Coating Thickness Gauge accurately measures the thickness of coatings on concrete and other similar substrates - non-destructive.ElcomThe Peter 500 coating thickness gauge can measure the repeatability and reproducibility of dry film thickness in concrete coatings up to 9mm thick, without damaging the coating.In standard mode with 60 readings per minute, and in scanning mode with readings exceeding 140 per minute - the Yigao 500 coating thickness gauge can significantly reduce detection time.Equipped with intelligent and ergonomic probe selection, specifically designed for continuous use and advanced on-site replaceable probes, you can conduct daily inspections throughout the day.Ultrasonic Gauge 500 Coating on ConcreteThe built-in signal strength indicator of the instrument can prevent false or incorrect readings, because if the signal strength indicator turns green, the instrument will display the coating thickness measurement.Durable and sturdy, ergonomic, sealed to prevent dust and water, equivalent to aThe rating is IP54, and the Engel 500 dry film thickness gauge is designed to operate in harsh environments.Incredible ease of use, the Engel 500 coating thickness gauge for concrete can be used in accordance with ASTM D6132, SSPC PA9, and ISO 2808 method 10.Due to the fact that inspectors can spend up to 30% of their work week generating reports, ElcoMaster ® Save time and money by creating professional customized reports in seconds - even on-site.
How to use the YiGao 500 coating thickness gauge to measure the coating on concrete?
The Jig 500 coating thickness gauge can also measure the film thickness on substrates, including gypsum boards, drywall, concrete blocks, bricks, etc., without damaging the coating. The advanced measurement technology of the YiGao 500 means that you no longer need to know how thick the coating should be before taking readings, and you do not need to set any measurement gates or range values Just turn on the instrument, select the coating from the calibration library, and take a reading - it's that easy.
| major function | |
|
fast The Jig 500 coating thickness gauge can significantly reduce detection time. reliableIf the signal strength indicator light turns green, the Jig 500 will only display the coating thickness reading to prevent false or incorrect readings. If the coating thickness is outside the measurement range, the Jig 500 will tell you on the display screen. intelligenceThe Hiker 500 measuring probe comes with a user replaceable probe end. If the end is damaged or used beforeDuring the process of wear and tear, you can replace it and continue. The instrument will even notify you when it is necessary to replace the probe end, optimizing the detection time. Easy to useThere is no need to set gates, range values, or know the thickness of the coating. Simply select the coating material from the instrument library and start measuring. Ergonomic Design: The Engel 500 and smart probe have been fully ergonomically designed for continuous use. No need to exert force to take readings. strongDurable and sturdy, ergonomic, sealed to prevent dust and water, equivalent to IP54 rating The Jig 500 is designed to be used in harsh environments, making it an ideal instrument for laboratories or work sites. |
![]() |
|
Calibration of different modes:User calibration adjustments for the Elg 500The program is fully traceable to national and international standards. |
||
|
1. Coating material library: The advanced measurement technology of the Engel 500 meansyouNo longer needed knowHow thick is the coating, or set a measuring door before taking readings. Just open the instrument, select the coating from the calibration library, and take a reading. It's just that easy. |
2. Material thickness calibration: To achieve excellent measurement accuracy, the Jig 500 can utilize Calibrate based on the known thickness of the coating being tested. If the thickness of the sample is known Yes, it is not provided. The calibration mold (CCM) for the Yigao 500 coating can be used to create one individualThe known coating thickness can be traced back to national and international standards. |
3. Sound velocity calibration: The Jig 500 can be obtained from the product data sheet provided by the coating manufacturer Calibrate the speed of the input sound. |
How to calibrate the Yigao 500 coating thickness gauge?
Introducing ultrasonic measurement technology, each instrument can be calibrated in one of three ways - to the known thickness of the coating to be tested; By setting the sound velocity of the coatingOr by selecting coatings from a general list or user-defined coating materials.Once the instrument has been calibrated, the Yigao 500 has a measurement accuracy of ± 2%.
How to use Yigao Coating for calibrationQuasi modelEquipment (CCM)Create a coating thickness sample for Yigao 500?
The Yigao CCM and Yigao 500 calibration used in this way can be traced back to national and international standards. User defined coatings can be transferred toElcoMaster's internal coating material library can be used at any time on any Yigao 500 instrument. Select the paint from the list and transfer it to any Yi Gao 500 instrument.More information on how to use the calibration mold for the Easy High Coating with the Elgar 500 coating thickness gauge can be found on the attachment page.
|
Technical Parameter |
||
|
model |
A500C-B |
A500-C |
|
measuring range |
useT500-c1Probe,150~2500μm useT500-c2Probe,, 70~1000μm |
|
|
Resolution (user selectable) |
low10μm,0.01mm tall1μm,0.001mm |
|
|
Measurement rate |
Reading per minute60+ |
|
|
storage |
not have |
1000data set100000A data |
|
operate temperature |
-10~50℃(14~122℉) |
|
|
power supply |
2×AABatteries, dry batteries can also be used |
|
|
BATTERY LIFE |
Alkaline battery: approximately15Hour, lithium battery:make an appointment28hour |
|
|
weight |
161g |
|
|
size |
141×73×37mm |
|