Product Introduction of WNS Low Nitrogen Condensing Gas Steam Boiler with Four way Boiler
The WNS low nitrogen condensing gas steam boiler adopts a horizontal internal combustion two return wet back structure. The waveform combination furnace is the first return, and the second return is composed of threaded smoke pipes. The rear tube plate of the boiler is not directly washed by high-temperature flue gas, and the working conditions are improved. At the same time, this structure greatly reduces the heat dissipation loss at the rear of the boiler. To improve thermal efficiency, an energy-saving device and a condenser are arranged in sequence at the outlet of the front smoke box of this type of boiler, which has a significant energy-saving effect. This boiler has high and low water level alarm functions, low water level interlock protection functions, and overpressure interlock protection functions. In order to effectively monitor and control water level and pressure, this boiler is equipped with a water level gauge, an electrode type water level control alarm, a pressure gauge, and a pressure controller, which enable the boiler to have high and low water level alarm/low water level interlock protection, steam pressure overpressure interlock protection, automatic ignition of the boiler, automatic adjustment of burner firepower, and shutdown protection, ensuring the safe operation of the boiler.
The fuel of this product is sprayed out from the burner, ignited by high-pressure electronic ignition, and burned under slight positive pressure in the furnace chamber. The high-temperature flue gas after combustion enters the second return path by turning 180 ° from the rear smoke chamber, and then enters the energy-saving device and condenser through the front smoke box, and is discharged into the atmosphere through the chimney.
The front smoke box adopts an integral double door setting, with double-layer sealing of the smoke box door. This form has good integrity, beauty, and elegance, and is also easy to open during maintenance.
The chimney height is configured to be 8 meters before leaving the factory. Users should determine the actual height according to the requirements of the environmental impact assessment report approved by the local environmental protection department, but not less than 8 meters.
Four-way boilerProduct image of WNS low nitrogen condensing gas steam boiler
Four-way boilerProduct characteristics of WNS low nitrogen condensing gas steam boiler
(1) Adopting a bottom mounted furnace, corrugated furnace liner, and integrated condensing design with two flue gas return paths, the smoke and dust emissions meet national environmental protection requirements.
(2) The furnace adopts a corrugated furnace liner, which greatly improves the heating surface and strength.
(3) Reasonable and compact structure, strong load adaptability, complete combustion, and high thermal efficiency.
(4) The boiler has a large heating surface area, fast temperature and pressure rise, and easy operation.
(5) The safety accessories of the main body are complete, ensuring safe and economical operation.
(6) Equipped with Lialu burner, the combustion is stable and reliable.
(7) High degree of automation, saving labor.
(8) The boiler has a small volume, light weight, small footprint, and low infrastructure investment.
Four-way boilerTechnical parameters of WNS low nitrogen condensing gas steam boiler products
| model |
WNS1-1.25-Q |
WNS2-1.25-Q |
WNS4-1.25-Q |
WNS6-1.25-Q |
| rated evaporation |
1t/h |
2t/h |
4t/h |
6t/h |
| Rated steam pressure |
1.25MPa |
1.25MPa |
1.25MPa |
1.25MPa |
| Rated steam temperature |
194℃ |
194℃ |
194℃ |
194℃ |
| feed water temperature |
20℃ |
20℃ |
20℃ |
20℃ |
| Energy saving device inlet/outlet temperature |
40℃/90℃ |
42℃/78℃ |
40℃/90℃ |
40℃/76℃ |
| Inlet/outlet temperature of condenser |
20℃/40℃ |
20℃/42℃ |
20℃/40℃ |
20℃/40℃ |
| blowdown rate |
3% |
3% |
3% |
3% |
| Cold air temperature |
20℃ |
20℃ |
20℃ |
20℃ |
| Design exhaust temperature |
55.16℃ |
55.56℃ |
55.16℃ |
52.1℃ |
| Low heating value of natural gas |
35590KJ/Nm³ |
35590KJ/Nm³ |
35590KJ/Nm³ |
35590KJ/Nm³ |
| Heating area |
radiation |
6.93㎡ |
14.67㎡ |
9.73㎡ |
19.41㎡ |
| convection |
13.55㎡ |
52㎡ |
28.89㎡ |
91.13㎡ |
| economizer |
11.84㎡ |
32.16㎡ |
22.56㎡ |
56.16㎡ |
| condenser |
14.8㎡ |
48.24㎡ |
28.2㎡ |
74.88㎡ |
| Design fuel consumption |
79Nm³/h |
314.43Nm³/h |
158Nm³/h |
470.91Nm³/h |
| Design thermal efficiency |
97.45% |
97.43% |
97.45% |
97.58% |
| Condensation conversion thermal efficiency |
100.6% |
100.58% |
100.6% |
100.73% |
| RIELLO low nitrogen gas burner |
Burner back pressure |
1050Pa |
1300Pa |
900Pa |
1600Pa |
| output power |
300/600~1300KW |
500/1500~4450KW |
300/930~1860KW |
1000/2200~6250KW |
| internet traffic |
30/60~130Nm³/h |
50/150~440Nm³/h |
30/93~186Nm³/h |
100/220~620Nm³/h |
| Motor Power |
2.2KW |
9.2KW |
4.5KW |
15KW |
| Comparison method |
Mechanical tuning |
Electronic tuning |
Electronic tuning |
Mechanical tuning |
| NOx emission concentration |
<80mg/Nm³ |
<80mg/Nm³ |
<80mg/Nm³ |
<80mg/Nm³ |
| feed pump |
electric power |
2.2KW |
4KW |
3KW |
5.5KW |
| internet traffic |
1.6m³/h |
4m³/h |
2.8m³/h |
7m³/h |
| lift |
148m |
153m |
158m |
156m |
| Excess air coefficient at the exit |
1.075 |
1.075 |
1.075 |
1.075 |
| Boiler body weight |
3260Kg |
8766Kg |
5450Kg |
10220Kg |
| Weight of energy-saving device body |
216Kg |
|
|
816Kg |
| Weight of condenser body |
290Kg |
|
|
1108Kg |
| Boiler transportation weight |
6300Kg |
11830Kg |
8220Kg |
15300Kg |
| Boiler transportation dimensions (length, width, height) |
3750*2020*2870mm |
5186*2470*3590mm |
4286*2181*3135mm |
5830*2520*3050mm |
| Boiler installation dimensions (length, width, height) |
4250*3215*3165mm |
6105*3655*3700mm |
4855*3425*3400mm |
6750*4010*3980mm |
| Power Consumption |
4.4KW |
13.2KW |
8.5KW |
20.5KW |
For more information on WNS low nitrogen condensing gas steam boilers, please call 400-002-9989
Four-way boilerWNS low nitrogen condensing gas steam boiler product operation test site
WNS low nitrogen condensing gas steam boiler product delivery site
In 2018, the new ultra-low nitrogen emissions of 30mg, 80mg, 120mg, 150mg, and 200mg were matched with original imported burners for free selection! Sales hotline: 13673423999.
The specific models are as follows:
1. WNS1-1.25-Q one tonIntegratedLow nitrogen condensing gas steam boiler;
2. WNS2-1.25-Q Two tonsIntegratedLow nitrogen condensing gas steam boiler;
3WNS4-1.25-Q four tonsIntegratedLow nitrogen condensing gas steam boiler;
4WNS6-1.25-Q six tonsIntegratedLow nitrogen condensing gas steam boiler;
5. WNS8-1.25-Q eight tonsIntegratedLow nitrogen condensing gas steam boiler;
6. WNS10-1.25-Q Ten tonsIntegratedLow nitrogen condensing gas steam boiler.