WNS type fuel (gas) steam boiler

NegotiableUpdate on 04/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
WNS type fuel (gas) steam boiler
Product Details
WNS type fuel (gas) steam boiler content description:

The WNS type fuel (gas) steam boiler is a horizontal fast loading internal combustion three return fire tube boiler. Adopting a biased furnace bladder wet back structure, high-temperature flue gas sequentially flushes the second and third return flue pipes, and then is discharged into the atmosphere through the chimney from the rear flue chamber. The boiler is equipped with movable front and rear smoke box covers, making boiler maintenance convenient. The boiler is equipped with a burner with excellent technical performance, and adopts advanced technologies such as automatic proportional adjustment of combustion, automatic adjustment of feedwater, program start stop, and fully automatic operation. It also has high and low water level alarms and automatic protection functions such as extremely low water level, ultra-high steam pressure, and shutdown. This type of boiler has the characteristics of compact structure, safety and reliability, easy operation, rapid installation, low pollution, low noise, and high efficiency.
WNS type fuel (gas) steam boiler fuel: fuel oil, gas

Main features:
1. The overall structure is reasonable, compact, and belongs to the boiler island type, which meets the requirements for quick installation and factory delivery. This product is composed of three main parts when it leaves the factory; The boiler main engine, chimney, and piping system, including the main engine and chimney parts, have been manufactured in the factory. The pipeline valves and instruments matched with the main engine have been randomly installed and transported to the site for assembly. Connect the gas source, power supply, and water pipeline on site to start the test drive. Greatly shorten the installation cycle and ensure product quality.
2. Advanced design performance.
The main engine of the boiler belongs to the integral structure, and the burner is assembled on the front smoke box cover. The main body is mainly arranged with the heating surface and combustion chamber. The utility model has reasonable and compact structure, low steel consumption, offset corrugated furnace liner, new light thermal insulation material for the insulation layer, color sheet for the outer packaging, and cuboid shape for the outer packaging, which makes the boiler performance, weight, structural size, and appearance have obvious progressiveness and beauty compared with domestic products of the same volume.
The boiler water supply equipment is configured on the boiler base on the right side of the boiler to be integrated with the main engine, without the need for a separate foundation.
3. The water cycle is simple, the structure of the compressed parts is reasonable, and it can operate safely while ensuring water quality.
4. The supporting auxiliary equipment is complete and the comprehensive technical performance is advanced.
The working process of the boiler:
The fuel enters the burner from an external gas source and generates high-temperature flames through automatic adjustment and ignition functions. It enters the combustion chamber from the front end of the furnace and enters the convective heating surface on the upper side of the rear combustion chamber. It then enters the second convective heating surface through the upper part of the front chimney and leaves the boiler at the rear of the rear chimney before being discharged into the atmosphere through the chimney. If smoke and dust are generated due to improper air conditioning, they can settle separately in the front and rear smoke boxes and the combustion chamber. Opening the inspection door can completely clean them up. The working fluid generates saturated steam through heating and outputs it to the operating system through the main steam valve.
WNS type fuel (gas) steam boiler protection device

1. Real time monitoring function of steam boiler water level: equipped with electronic water level detection device, real-time monitoring of boiler water level.
2. Steam boiler time setting function: Users can freely combine and set the start and stop time of the boiler according to their needs.
3. Steam boiler leakage protection function: When the control system detects a leakage in the electric heating element, it will automatically cut off the power supply.
4. Steam boiler water shortage protection: When the boiler is short of water, the burner control circuit should be cut off in a timely manner to prevent dry burning and damage to the burner. At the same time, the controller will issue a water shortage alarm indication.
5. Abnormal protection function of steam boiler power supply: The boiler immediately stops running.
6. Steam boiler overpressure interlock protection: When the pressure inside the boiler exceeds the user set value, the burner is prohibited from working and an alarm is triggered.
7. Multiple safety protections such as steam boiler pressure controller, water level alarm, safety valve, and extremely low water level alarm.
8. Complete gas valve assembly and protection system for steam boilers: providing a complete gas valve assembly and accessories including filters, pressure regulating valves, solenoid valves, etc., to ensure the safety of gas.
9. The steam boiler flue gas monitoring device can automatically monitor the exhaust temperature of the boiler, making it more convenient to grasp the combustion situation of the boiler.

WNS Series Horizontal Oil/Gas Steam Boiler - Technical Parameters

model
WNS0.5-0.4(0.8)
-Y(Q)
WNS0.75-0.4(0.8)
-Y(Q)
WNS1-0.8(1.0)
-Y(Q)
WNS1.5-1.0
-Y(Q)
WNS2-1.0
-Y(Q)
WNS3-1.25
-Y(Q)
project
parameter
Rated thermal power (MW)
0.5
0.75
1
1.5
2
3
Rated working pressure (MPa)
0.4(0.8)
0.4(0.8)
0.8(1.0)
1.0
1.0
1.25
Inlet/outlet water temperature (℃)
152(175)
175(184)
184
184
194
Design efficiency (%)
85%-92%
Water volume (m3)
1.2
1.56
2.10
2.7
2.7
5.9
Full water weight (t)
4.48(5)
5.76(6.2)
6.48(7.1)
8(8.4)
8(8.4)
16(16.8)
Power consumption (KW)
3.6
3.6
5.9
15.8
17.7
19.7
Power supply (V)
380
Applicable fuel
Light oil, natural gas, heavy oil, city gas, liquefied petroleum gas
Calculate consumption:
Light oil (kg/h)
Natural gas (m3/h)
Heavy oil (kg/h)
City gas (m3/h)
Liquefied petroleum gas (m3/h)
34
41
35
92
14

51
62
53
138
20

65
82
70
184
26
102
123
105
276
39
136
164
140
368
52
204
246
210
552
79
Length x Width x Height (mm)
2650×1600
×1700
2650×1600
×1800
3650×1800
×1800
5200×2300
×2400
5200×2300
×2400
5570×3200
×2670
peaceful
dress
chi
cun
Inlet/outlet valve diameter (mm)
50
65
65
65
65
100
Diameter of drain valve (mm)
40
40
40
40
40
40
Diameter of safety valve (mm)
40
2×40
2×40
2×50
2×50
2×65
Chimney diameter ф (mm)
250
300
320
360
360
360
★ Note ★We will provide accurate information on this website as much as possible. The product images on this website may have slight differences from the actual products. The effect demonstration and schematic diagrams are for reference only (some images are composite, simulation demonstration, and effect diagrams). For the appearance (including but not limited to color) of the four-way boiler product, please refer to the actual product. Product prices, specifications, models, and supply status are subject to change without prior notice.

model
WNS4-1.25
(1.6)-Y(Q)
WNS5 -1.25
(1.6)-Y(Q)
WNS6-1.25
(1.6)-Y(Q)
WNS8 -1.25
(1.6)-Y(Q)
WNS10 -1.25
(1.6)-Y(Q)
WNS15 -1.25
(1.6)-Y(Q)
WNS20 -1.25
(1.6)-Y(Q)
project
parameter
Rated thermal power (MW)
4
5
6
8
10
15
20
Rated working pressure (MPa)
1.25(1.6)
Outlet/Return Water Temperature (℃)
194(204)
Boiler design efficiency (%)
85%-92%
Water volume (m3)
7.14
10
10.2
13.9
16.7
30
30
Full water weight (t)
22(23.5)
24.7(26)
25.5(26.5)
32.5(34.5)
38(42)
74(78)
78(82)
Power consumption (KW)
22.2
34.4
34.4
36
36
72
72
Power supply (V)
380
Applicable fuel
Light oil, natural gas, heavy oil, city gas, liquefied petroleum gas
Calculate consumption:
Light oil (kg/h)
Natural gas (m3/h)
/Heavy oil (kg/h)
City gas (m3/h)
Liquefied petroleum gas (m3/h)
272
328
280
736
105
241
413
352
922
131
382
429
377
972
139
482
429
377
972
139
603
715
628
1620
231
904
1075
942
2430
347
1206
1430
1256
3240
462
Length x Width x Height (mm)
5600×3300
×2880
6020×3300
×3060
7200×3300
×3060
7300×3300
×3060
7400×3300
×3060
8100×4200
×4100
8500×4500
×4100
peaceful
dress
chi
cun
Inlet/outlet valve diameter (mm)
100
125
125
150
150
200
200
Diameter of drain valve (mm)
2×40
2×40
2×40
2×40
2×40
2×40
40
Diameter of safety valve (mm)
2×50
50×80
50×80
2×80
2×80
2×80
2×100
Chimney diameter ф (mm)
530
530
530
680
380
1000
1200
★ Note ★We will provide accurate information on this website as much as possible. The product images on this website may have slight differences from the actual products. The effect demonstration and schematic diagrams are for reference only (some images are composite, simulation demonstration, and effect diagrams). For the appearance (including but not limited to color) of the four-way boiler product, please refer to the actual product. Product prices, specifications, models, and supply status are subject to change without prior notice.