1、 Working principle of wheat (grain) specific level gauge:
The structure of the FY2BLS series wheat (grain) specific level gauge is divided into two parts: the main electrode and the compensating electrode. When the material is attached, the internal amplifier amplifies the signal, and the compensating electrode provides a signal to the main electrode to reset the signal signal, ignoring the currently attached material. The phase and potential of the compensating electrode RF signal are the same as those of the main electrode RF signal, which is used to cancel the signal generated by the material adhering to the induction rod and provide the correct material detection signal!

Manufacturer's price:
| price | ¥ 480.00~56700.00 yuan |
| Starting from batch | ≥1 tower |
| Customized processing | correct | brand | Vauen | model | SYRD800 |
| type | Pulse type radar level gauge | measuring range | 0~70M | measurement accuracy | 1 |
| current signal | 4~20(mA) | power supply | 24VDC | Operating Frequency | 26GHZ |
2、 Product features of wheat (grain) specific level gauge:
1. Strong universality: suitable for various occasions, can detect particles, fly ash, conductive and non-conductive liquids, viscous materials;
2. Anti adhesion circuit: Advanced anti adhesion circuit design can eliminate false error signals caused by material adhesion;
3. Power loss protection mode: low or high fault alarm. On site adjustable.
4. Easy to install and adjust
5. Not afraid of sticking or hanging materials
6. Good stability, not affected by temperature
7. Delay output adjustable
8. Optional temperature resistance * * * up to 550 ℃
9. High and low position failure protection function Adjustable delay output
10. Zero point, range, button adjustment, and one key input of wheat specific level gauge. Zero point and range adjustment are not related to each other and have no sequence, and can work normally in one go.
11. The wheat specific level gauge adopts digital software filtering technology, which is not affected by gas volume and liquid level fluctuations. It can quickly track transient changes and display the average liquid level. It can achieve longer damping and sampling times without causing visual fatigue to monitoring personnel.
12. The working voltage of the wheat specific level gauge can work normally within the range of 8-30VDC, similar to a circuit. However, due to hardware limitations, the working voltage is above 14VDC. When a smaller safety barrier is used, a slightly higher liquid level can cause a voltage drop, resulting in abnormal display and misleading operators or even causing accidents.
13. The wheat specific level gauge adopts software and hardware interference and super strong error correction technology, which does not require isolation in non explosion proof places and can be directly connected to the network.
14. Wheat specific level gauge with on-site LCD display, equipped with various communication interfaces and debugging interfaces.
15. Wheat specific level gauge calculates the zero point and range based on two-point true values, automatically calculates and stores them.
16. Use a wheat specific level gauge to check the current true capacitance value.
Any medium with a dielectric constant greater than or equal to 1.4 can be measured
Suitable for measuring liquids (diesel, gasoline), solid small particles, powder media (cement), and media with high dust emissions
It is suitable for measuring obvious volatile gas media, and for media applications such as foam, wall hanging and scaling, surface fluctuation, bubbling or boiling, high-frequency loading and unloading, and dielectric constant or specific gravity change under ultra-low liquid level conditions
3、 Main technical parameters of wheat (grain) specific level gauge:
1. Power supply voltage: 24VDC ± 5%;
2. Output signal: 4-20mA DC
3. Environmental temperature: -40~70 ℃;
4. Sensitivity setting: 0.5-500pF (adjustable);
5. Delay time: adjustable from 0 to 30 seconds (on or off);
6. Power loss protection mode: low or high fault alarm, adjustable on site.
7. Installation form: ⑴ Flange installation: According to the flange standard provided by the user;
8. Measurement range: pole type 300-5000mm
9. Work pressure: 0-32 MPa
10. Working temperature: -70 ℃~+250 ℃
11. Working voltage: 24VDC, powered by safety barriers
12. Output signal: 4-20m ADC
13. Explosion proof mark: EXib11BT5
14. Intrinsic safety parameters: idui: 28V Li: 93m A Pi: 0.65w Ci: 0.28uf Li: 1.5Mh
15. Nominal flange: see High Pressure Appendix 2
16. Applicable media: wheat, (grain)
4、 Application scope of wheat (grain) specific level gauge:
Level detection and control of various liquids and particles such as powder silos, water wells, water tanks, drug cartridges, acid and alkali tanks.
Ordering Instructions for Wheat Specific Level Gauge
1. Measurement range
2. Work pressure
3. Connecting flange
4. Plug in or floating type
6、 Precautions
If there is a pressure difference in the equipment, the high-pressure external float type liquid level gauge cannot be used (show the high-pressure equipment drawing)
Parameters of guided wave radar level gauge:
|
|
|
|
|
|
category
|
YPRD61
|
YPRD62
|
YPRD63
|
|
application
|
Liquid, solid small particles and powders
|
Liquid, solid small particles and powders
|
liquid
|
|
measuring range
|
20 meters (expandable to 30 meters)
|
6 meters
|
6 meters
|
|
Process connection
|
Threads, flanges
|
Threads, flanges
|
Threads, flanges
|
|
process temperature
|
-20-220℃
|
-20-220℃
|
-20-220℃
|
|
Process pressure
|
-1.0-40bar
|
-1.0-40bar
|
-1.0-60bar
|
|
accuracy
|
< 0.1%
|
< 0.1%
|
< 0.1%
|
|
resolution
|
1mm
|
1mm
|
1mm
|
|
repeatability
|
±3mm
|
±3mm
|
±3mm
|
|
Frequency range
|
100MHZ-1.8GHZ
|
100MHZ-1.8GHZ
|
100MHZ-1.8GHZ
|
|
Explosion proof protection level
|
Exd II BT4/IP68
|
Exd II BT4/IP68
|
Exd II BT4/IP68
|
|
signal output
|
4... 20mA/HART (two-wire)
|
4... 20mA/HART (two-wire)
|
4... 20mA/HART (two-wire)
|
Selection of Wheat Radar Level Gauge and Rice Radar Level Gauge:
YPRD60 instrument model, * * * large range,