Z-1200 portable ozone detector

NegotiableUpdate on 03/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Product Introduction: The sensitive component of Z-1200 ozone detector is a four electrode electrochemical cell Including working electrodes and auxiliary electrodes. Auxiliary electrodes are used for temperature compensation to improve the selectivity of the electrode system. The sensor response signal is linear with the concentration of gases in the air.
Product Details

    Z-1200 Ozone DetectorThe sensitive component is a four electrode electrochemical cell Including working electrodes and auxiliary electrodes. Auxiliary electrodes are used for temperature compensation to improve the selectivity of the electrode system. The sensor response signal is linear with the concentration of gases in the air. The Z-1200 ozone detector is used for detecting disinfectant gases and residual disinfectant gases, and is widely used in hospitals, public places, food processing plants, swimming pools, and other places.

    The 1200 handheld direct reading instrument is a measuring and analyzing instrument for measuring the concentration of ozone in the air from 0 to 10 ppm (specifically increased by our company) with a resolution of 0.01 ppm. This model has a LCD display screen, low battery indicator light, and a sound alarm that can be set to any standard within the range. The LCD screen outputs the current ozone concentration every 10 seconds, the highest measured value, the average value over the past 15 minutes, and the average value over the past 8 hours, which can be viewed at any time. The data storage device stores all measurement points used each time and can be downloaded to a personal computer through software.

    Operating principle: An electrochemical unit is used in the measuring element. Each unit uses four types of electrodes and includes one working and one active compensating electrode. The signal improves the selectivity of the entire sensor by using temperature compensation to supplement the electrode, and the sensor can measure the concentration of ozone in the air in a straight line.

      Z-1200 Ozone DetectorCharacteristics:

    easy to use

    built-in pump

    Rechargeable battery

    Built in memory (data recording)

    Short term and long-term average calculation

     Product Parameters

    Sensor type: Electrochemical

    Measurement range: 0-2 ppm

    Maximum value: 5 ppm

    Resolution: 0.01 ppm

    Lifespan: Over 2 years

    Response time:<150 seconds

    Operating temperature: -20 ° C to+50 ° C

    Relative humidity range: 15-90% without condensation

    Alarm: 80 dB audible prompt sound

    Size: 4.75 "x2.5" x1.5“

    Weight: 170 gms

    Power supply: 9V alkaline battery