Thermo Finnigan LCQ DECA XP Plus liquid chromatography-mass spectrometry (LC-MS) is a multifunctional analysis platform based on ion trap technology. Its core performance is reflected in three areas: high sensitivity multi-stage mass spectrometry capability, wide dynamic range detection, and adaptability to complex matrix analysis.
Thermo Finnigan LCQ DECA XP Plus liquid chromatography-mass spectrometry is a multifunctional analysis platform based on ion trap technology, and its core performance is reflected inHigh sensitivity multi-stage mass spectrometry capability、Wide dynamic range detectionandAdaptability of complex matrix analysisThree major areas. The following is a detailed performance analysis of the system:
1、 Core technical parameters and hardware configuration
Quality Analysis System
Ion trap technologyAdopting a three-dimensional quadrupole ion trap design, with a range of mass to charge ratiosm/z50-4000 (protein detection limit up to 60000 Da), supporting up to 10 levels of tandem mass spectrometry (MS)^n,n=10)The signal-to-noise ratio is 50:1.
Sensitivity and accuracyThe detection limit is as low as 10 pg, with a mass accuracy of<0.1 Da, suitable for trace substance analysis.
Ion source and liquid phase system
Electrospray ionization source (ESI): The spray voltage is adjustable from 0-8000 V, the capillary temperature is 135-350 ℃, and it is suitable for the analysis of thermally unstable compounds.
Liquid chromatography combinedStandard binary pump system (pressure resistance of 5000 psi), flow rate of 0.01-10 mL/min, compatible with sub-2 µ m chromatographic columns, and DAD detector wavelength range of 190-950 nm.
Injection and Temperature Control
Dual mode injectionSupports automatic sampler (120 bit sample tray) and flow injection injection, with sheath gas/auxiliary gas flow rates of 100 arb and 20 arb, respectively.
Column temperature control boxThe temperature control range is 4-40 ℃ to ensure the separation stability of complex samples.
2、 Intelligent functions and workflow
Data Collection and Analysis
Multi mode scanningFull scan, selective ion monitoring (SIM), data dependent scanning (DDA), etc., combined with Xcalibur software to achieve automated data processing.
Structural analysis abilityThrough multi-level mass spectrometry fragment comparison, it supports the identification of unknown compound structures, especially suitable for natural product and metabolite research.
Method development efficiency
Quick switching functionComplete ESI/APCI ion source switching within 5 minutes to meet the analysis requirements of different polar compounds.
Dynamic range optimizationThe linear dynamic range reaches 5 orders of magnitude, meeting the quantitative requirements from trace to high concentration samples.
3、 Application scenarios and performance validation
Drug development and metabolic research
Environment and Food Safety
proteomics
4、 System reliability and scalability
modular designCan be upgraded to Orbitrap high-resolution modules or combined with UPLC systems to improve resolution and throughput.
Maintain convenienceThe ion source component supports quick disassembly with an annual downtime rate of less than 5%.
This platform relies onLevel 10 MS^nIn-depth analysisandPG level sensitivityBecoming an ideal tool for identifying small molecule structures and analyzing complex matrices.