GTI Pipeline Leakage Tester Q90 Jitai Precision InstrumentMainly used for sealing testing of air conditioning ducts, it can inspect segmented ducts and the installed main duct of the entire system to ensure the efficiency of the air conditioning system and avoid energy waste. This instrument performs testing according to relevant identification standards and can directly determine whether the sealing of the pipeline is qualified. Using touch screen operation, 5-inch LCD color screen display, good human-machine interface for convenient user operation. The application field pipeline air leakage testing machine is mainly used for sealing testing of air conditioning pipelines, as a specialized equipment for testing air leakage in ventilation and air conditioning systems. It is suitable for testing the tightness quality of air ducts, air conditioning units, fire dampers, regulating valves, etc. in hotels, restaurants, and public engineering ventilation and air conditioning systems.

Can detect the sealing performance of pipelines under positive and negative pressure
Assess the sealing performance of pipelines based on the following standards:
EN1507:2006,EN12237:2002,Eurovent2/2,DW/143,
SMACNA Standard,GB50243--2002
Wide air volume measurement range, two measuring tools ensure measurement accuracy
The appraisal results can directly determine whether the pipeline sealing is qualified
Real time display of leakage volume, test pressure, temperature, and atmospheric pressure
1000 sets of data storage, browsing, and deletion
4.7-inch LCD touch screen, easy to operate
Simple structure and easy installation
GTI Pipeline Leakage Tester Q90 Jitai Precision InstrumentTechnical Specifications
Model number |
DALT6900 |
|
Traffic volume |
Scope |
Matrix: 36-640 m3/h Nozzle: 4-36 m3/h |
Accuracy |
± 2.5% ± 0.1 m3/h of reading |
|
resolution |
0.01 m3/h |
|
Static pressure |
Scope |
± 2500 Pa |
Accuracy |
1% ± 1Pa of reading |
|
resolution |
0.1 Pa |
|
Temperature |
Scope |
0~60 ℃ |
Accuracy |
±0.5 ℃ |
|
resolution |
0.1 ℃ |
|
atmospheric pressure |
Scope |
70~130kPa |
Accuracy |
± 2% of the reading |
|
resolution |
0.1kPa |
|
Power supply |
DALT 6900-0E |
100-120V, 1 Phase,50/60Hz,10A |
DALT 6900-1E |
200-240V, 1 Phase,50/60Hz,10A |
|
Weight |
Net weight approximately 72kg |
|
Size |
54*50*120cm |
|
Storage |
1000 sets |
|