Welcome Customer !

Membership

Help

Jitai Precision Instrument (Shenyang) Co., Ltd
Custom manufacturer

Main Products:

pharmamach>Products

Jitai Precision Instrument (Shenyang) Co., Ltd

  • E-mail

    info@gti-test.com

  • Phone

    17640053769

  • Address

    No. 56-39 Huanghe North Street, Huanggu District, Shenyang City, COFCO Plaza 7 # 2212

Contact Now

GTI aerosol leak detection equipment for purification engineering 3990-03

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The GTI aerosol leak detection equipment 3990-03 for purification engineering is an aerosol generator that uses the Laskin Nozle method, has a built-in compressor, does not require any other gas source, and can work when powered on. Durable, portable and reliable. After injecting aerosol (PAO, etc.) solution, turning on the power, and adjusting the pressure to 20psi (0.14Mpa), when the flow rate is 50-2000cfm (85-3400m3/h), by adjusting Laskin Nozle, polydisperse suspended particles with a concentration of 10-100 μ g/L can be generated.

Product Details

GTI aerosol leak detection equipment for purification engineering 3990-03It is an aerosol generator that uses the Laskin Nozle method, has a built-in compressor, does not require any other gas source, and can work when powered on. Durable, portable and reliable. After injecting aerosol (PAO, etc.) solution, turning on the power, and adjusting the pressure to 20psi (0.14Mpa), when the flow rate is 50-2000cfm (85-3400m3/h), by adjusting Laskin Nozle, polydisperse suspended particles with a concentration of 10-100 μ g/L can be generated.

3990-03 is widely used in filter unit systems with flow rates not exceeding 2000cfm (3400m3/h), such as biosafety cabinets, laminar flow hoods, negative pressure filtration units, filtration modules, or movable clean units.

After the high-efficiency filter is put into operation, if there are leakage points or gaps due to insufficient installation, the predetermined purification effect cannot be achieved, and a leak test must be conducted on the high-efficiency filter. Due to the low concentration of atmospheric dust upstream of the tested high-efficiency filter, an aerosol generator needs to be used to supplement the dust to meet the testing conditions. By using an aerosol photometer to test the concentration of suspended particles upstream of the high-efficiency filter and conducting a uniform scanning test downstream, the leakage rate of the tested high-efficiency filter can be determined to determine whether there is leakage.

GTI Aerosol Generator 3990-03

Application field

Efficient filter validation

Nuclear Energy and Fuel

Pharmaceutical industry, electronics industry

Medical operating room, clean room

Biosafety cabinets, clean workbenches

Food processing, scientific experiments

......

Product features and advantages

Built in compressor, no need for other air sources, can work with power on

The concentration of suspended particulate matter can be adjusted from 10 to 100 μ g/L to meet different testing requirements

The flow range is adjustable from 50-2000cfm to meet the needs of different applications

Multiple aerosol solutions can be selected (PAO, DOP, Ondina EL...)

Stainless steel shell, pressure resistant design, no deformation due to excessive pressure

Large capacity chamber, ensuring long-term dust generation

......

GTI aerosol leak detection equipment for purification engineering 3990-03Technical Specifications

Model number

3990-03

flow range

50~2000cfm(85~3400m3/h)

concentration range

100 μ g/L @ flow rate 200cfm

10 μ g/L @ flow rate 2000cfm

Aerosol solution

PAO、DOP、 Multi dispersed (cold)

Gas source

Built in compressor

Method of occurrence

2 or 6 Laskin Nozzel

Overall dimensions

38(L)X27(W)X26(H)cm

Weight

18.5kg

Power supply

AC100~240V 50/60Hz

Configuration

Host, nozzle connector, operation manual

Optional selection

Portable protective case

Portable dust generation solution

The 3990-03 series Laskin Nozle aerosol generator is equipped with a built-in compressor and does not require any other gas source. It can work when powered on. Durable, portable and reliable. Multi dispersed suspended particles with a concentration of 10-100 μ g/L can be generated. It is a dust generating equipment used for testing biological full cabinets, laminar flow hoods, negative pressure filtration units, filtration modules, or movable clean units. If dust needs to be generated in air conditioning ventilation systems for all or local end high-efficiency filters, it is recommended to use aerosol generator 3990-02 with a larger flow range.

performance guarantee

The product comes with a calibrated pressure gauge that monitors the pressure adjustment value in real-time, requiring only 20psi (0.14Mpa), meeting electrical safety requirements. The 3990-03 series generator can be used in conjunction with the aerosol photometer 3990 to test the leakage rate of high-efficiency filters. Convenient for identifying and quantifying leakage points, for repair reference. The concentration range can be achieved within 10-100 μ g/L, but the flow rate varies depending on the generator model.

easy to operate

3990-03 adopts a stainless steel shell, which will not deform due to excessive pressure and is easy to clean. Equipped with a solution visual window, oil mist discharge outlet, and stainless steel nozzle connector, it can guide dispersed suspended particles to a testing port at a farther location without leakage.

Portable protective case

Due to the heavy weight of the generator, a portable protective case is sometimes required when moving or transporting it. Internal scientific design, reasonable placement of relevant components.

Service&Training&Maintenance @ GTI

Product calibration, maintenance, and fault repair

Partners trained and certified by GTI service system

After sales service conducted

Thoughtful service, complete accessories, and timely repairs

GTI Aerosol Generator 3990-03