E-mail
734615775@qq.com
-
Phone
13770629460,13851661680
-
Address
Changjiang Economic Development Zone, Qixia District, Nanjing City
Nanjing Tengyang Drying Equipment Factory
734615775@qq.com
13770629460,13851661680
Changjiang Economic Development Zone, Qixia District, Nanjing City
1Pharmaceutical factory V-type dry powder mixerpurpose
The all stainless steel V-type mixer is a mixing equipment for dry powder or granular materials in the pharmaceutical industry and other industries. It is widely used in industries such as chemical, pharmaceutical, food, plastic, cosmetics, ceramics, metallurgy, etc.
2、 Structural characteristics and performance
Pharmaceutical factory V-type dry powder mixerDue to the unequal length of the two cylindrical tubes, an asymmetry is formed. When the mixer rotates, the material is decomposed and combined, and due to different potential energies, a lateral force is generated to push the material to exchange horizontally. When the material is combined and decomposed, there is also a lateral force due to the different planes of the material, which drives the material to exchange horizontally. After another round of lateral force, about 25% of the material flows from one tube to the other, so that the material is mixed horizontally and radially. The decomposition and combination intersect to achieve very uniform mixing of the material. When the material is mixed, there is no mechanical compression or strong wear, and the material particles are kept intact, making it easy to discharge and clean during product replacement. Mixing in a closed state provides good conditions for dust-free operation.
IIICompliant with GMP standard 304 stainless steel V-type mixer
| project
model | capacity L | Cylinder rotation speed rpm | Rotation height mm | Power rating KW | loading capacity Kg/time | Overall dimensions Length × Width × Height |
| TY-VH-1000 | 1000 | 12 | 2250 | 3 | 500 | 2350×900×2250 |
4、 Outline structure diagram

5、 Precautions for use
5. Non electricians are prohibited from carrying out live repairs.
6. This equipment adopts 380V+N50HZThree phase five wire system circuit.
7. It is prohibited to start both forward and reverse directions simultaneously.
8. The reducer of this equipment needs to be refueled and replaced with oil according to routine mechanical maintenance.