CO2TR permeation analyzer
PERMATRAN-C 4/30 CO2The permeation analyzer can test the carbon dioxide permeability (CO) of high and low barrier membranes and packaging2TR)。 It has two independent test chambers with interchangeable horizontal test chambers for easy and accurate testing Multiple sample sizes and packaging materials.
high precision
MOCON's modulated infrared sensor is a modulation sensor system on the market that complies with the ASTM F2476 standard
CO2The detection limit of TR is as low as 0.5cc/(m2x day)
Fully automatic temperature and flow control simplifies testing and provides repeatability
High throughput
Zahm Nagel CO2Compared to other testing methods, modulated infrared sensors can measure CO in real time2The gas concentration greatly reduces the overall CO2TR testing time
There are studies on the shelf life of Zahm NagelGood correlation, can achieve equivalence, and greatly shorten the long testing time
Automatic testing method, one click start testing
TruSeal nitrogen circulation seal can eliminate the need for absolute zero point in many tests, thereby reducing overall testing time
PERMATRAN-C 4/30The analyzer can testhigh and lowCarbon dioxide transmission rate (CO) of barrier films, packaging, and bottles2TR)。 Unlike pressure measurement methods or Zahm Nagel methods that require a long time to provide results,PERMATRAN-C4/30 adopts MOCON's modulated infrared sensor system, which can provide accurate results in a shorter time. This analyzer is designed specifically for various barrier materials and can operate between 0.5 and 8000/cc (m)2Provide highly reproducible test results within the range of days.The detection limit can be expanded by using a small area thin film testing chamber (coefficient x9) or by using masks of various sizes.
This analyzer has industry features such as a detachable and interchangeable horizontal testing chamber, an easy-to-use touchscreen interface, and fully automated testing, requiring minimal training to provide higher throughput in the laboratory.
For over 25 years, the MOCON PERMATRAN series analyzers have been the most reliable and durable instruments on the market. Compared with traditional methods, 4/30 can provide fast CO in a shorter time2As a result, it helps accelerate the development of new materials or efficient QC validation of existing products.
Features and Advantages
Detachable test chamber
Easily prepare samples on the workbench
More consistent analyzer membrane loading
One click release and loading
Pneumatic clamping ensures more reproducible results
Removable test chamber to expand testing capabilities
TruSeal®
Eliminate individual zeroing
Shorten testing time (improve throughput)
More reproducible results
Automatic control function
Flow and temperature control
Testing process development and recommendations
Programmable testing sequence
Printing and exporting test reports
Sensor protection
Touch screen interface
Intuitive automation operations require minimal training
Built in multi-level user management and data security
Event logs and troubleshooting guidelines
No need to use a computer, saving valuable laboratory space
Modulation infrared sensor
Shorten testing time, reduce overall testing time, and improve throughput
Long sensor lifespan
Accurate and reproducible results
Reliable modulated infrared sensor, compliant with ASTM F2476 standard
warranty
12-month 100% parts and process warranty
Modulation infrared sensor 4-year warranty
unit |
4/30 L-type |
|
Test scope (50cm2) |
cc/(m2× day) |
0.5 to 8000 |
cc/(100 in2× day) |
0.03 to 516 |
|
Test scope (5.6)cm2) |
cc/(m2× day) |
4.5 to 71000 |
cc/(100 in2× day) |
0.29 to 4600 |
|
test scope(5.0 cm2, obscured) |
cc/(m2× day) |
5 to 80000 |
| Resolution (50 cm)2) | cc/(m2× day) | 0.0001 |
| Test Scope - Packaging | cc/(pkg × day) | 0. 0025 to 40 |
| reproducibility | cc/(m2× day) | 0.25 or 2.0%* |
| Temperature control range | °C | 10 to 40 ± 0.2 |
| Humidity (RH) control range Test gas for thin film testing chamber |
% RH | Dry only |
PERMATRAN-C 4/30 |
unit |
Film size |
4-inch x 4-inch standard, 2-inch x 2-inch optional |
film thickness |
Up to 120 Mil |
Thin film testing area |
50 cm2 Standard Test Cabin |
Other specifications (all models):
15.5 inches high x 12 inches wide x 23 inches deep (39.4 cm x 30.4 cm x 58.0 cm)
95 pounds (43.1 kg)
Voltage: 100-240 VAC 50/60 Hz
Maximum power consumption: 700 VA
temperature |
operation |
22°C ± 2°C |
storage |
10 ° C to 30 ° C |
|
humidity |
operation |
20% to 80% RH (non condensing) |
storage |
5% to 85% RH (non condensing) |
carrier gas |
gas composition |
Nitrogen (99.7% N)2Or higher) |
Test gas |
gas composition |
Carbon dioxide (99.7% or higher) |
Remote access and control (requires optional Perm Net Light software)
Standard Ethernet port (100T)
Dual USB 2.0 ports (for connecting keyboards, mice, or storage devices)
This product is certified by UL and CSA, uses the ETL mark of Intertek Group plc, and has passed CE certification.
Meets the following international safety standards.
IEC 61010-1:2010 Third Edition
UL 61010-1:2012 Third Edition
CAN/CSA-C22.2 No. 61010-1:2012 Third Edition
Complies with the following international EMC standards.
EN 61326-1:2013
EN 61000-3-2:2006、A1:2009、A2:2009
EN 61000-3-3:2013
Compliant with the EU RoHS Directive 2011/65/EU.
CO2TR permeation analyzer