OX-TRAN 2/48 series packaging
The OX-TRAN 2/48 series oxygen permeability (OTR) analyzer is designed for testing whole packages or other three-dimensional samples in the environment. These 8-chamber instruments provide high throughput and can enhance the testing capabilities of your laboratory. The dual row design allows for adjustment of 4 samples while testing them. This parallel operation greatly improves the efficiency of the analyzer, while also providing MOCON accurate and reproducible results that meet your requirements. They adopt the same interchangeable packaging test chamber design as our other packaging test analyzers and fixtures. These breakthrough test chambers simplify the sample preparation process and improve the reproducibility of test results. There are various test chamber designs to choose from, which can accommodate different packaging sizes and types, and many test chambers do not even require the use of epoxy resin.
Efficient packaging testing
Parallel regulation and testing chambers have improved throughput
The automatic adjustment cycle shortens the time required to prepare test samples
High flow blowing cycle is more than 20 times faster than traditional methods
● Simple and safe installation of one click pneumatic testing cabin
The easy-to-use packaging test chamber saves time in preparing samples
The fast response Coulox sensor reduces testing time
Trustworthy results
Coulox from MOCON ® The sensor measures absolute values and does not require calibration
The Coulomb meter sensor has a long service life and comes with a 4-year warranty
The intrinsic sensor complies with ASTM D 3985 standard
Integrated TruSeal to lower the background level to a lower level, resulting in more accurate results
Adjust and test the automatic flow rate and relative humidity control of the chamber carrier gas
The OX-TRAN 2/48 analyzer can test the oxygen permeability (OTR) of high and low barrier membranes and packaging.
The simple user interface with automatic control function makes testing very easy, requiring minimal training. In some applications, starting a new test only requires pressing a button after loading the sample. Common testing methods can be stored and called for reuse. For new or unknown sample types, the automatic testing function will automatically adjust the testing parameters to provide optimized test results, and users do not need to have packaging experience.
Various test chambers can be used to test trays, bottles, soft containers, small bags, cups, laundry beads, bottle caps, seals, paper boxes, films, and almost any other type of three-dimensional samples. We also offer custom designed test chambers that simplify sample preparation and improve the reproducibility of testing.
Model:
This series of instruments has two models with different detection limits.
H-type (common barrier material) - detection range from 0.00025 to 1 cc/pkg * day
L-type (high barrier material) - capable of achieving a detection limit 10 times lower than H-type, with a detection range of 0.000025 to 1 cc/pkg * day
For over 25 years, the MOCON OX-TRAN series instruments have been reliable and durable in the market. The OX-TRAN 2/48 series is the latest product that takes whole package testing to a whole new level, enabling brand owners and packaging service providers to reliably test their finished packaging. It is very suitable for any testing laboratory that frequently tests whole packages or other 3D samples.
Characteristics and advantages
Easily prepare samples on the workbench, many without the need for epoxy resin
One click quick release and loading
One time installation of foil simplifies the installation of packaging
A dedicated test chamber box can save time and improve the repeatability of testing
Intelligent adjustment, can automatically and quickly blow to the desired settings
The automatic high flow regulation mode shortens the cycle
Before testing begins, quickly check if the packaging is installed correctly
Parallel adjustment and detection improve testing efficiency
Control of flow rate and relative humidity of carrier gas (regulating and testing chamber)
Develop "automatic testing" methods and provide corresponding suggestions for unknown samples
Printing and exporting test reports
Sensor protection
Intuitive automation operations require minimal training
Clear graphical display of testing and instrument status
Built in multi-level user management and data security
Event logs and troubleshooting guidelines
Shorten testing time, reduce overall testing time, and improve throughput
No need for sensor calibration
Long sensor lifespanThe warranty period is up to 4 years
The intrinsic sensor complies with ASTM D3985 standard
Eliminate individual zeroing
More reproducible results
Install the test chamber without the need for tools
12-month 100% parts and process warranty
Coulox Sensor 4-Year Warranty
unit |
L-shaped |
H-shaped |
|
test scope |
cc/(m2x day) |
0.005 to 200 |
0.05 to 200 |
cc/(pkg x day) |
0.000025 to 1.0 |
0.00025 to 1.0 |
|
Compensate to 100% O2Scope of testing |
cc/(m2x day) |
0.025 to 1000 |
0.25 to 1000 |
cc/(pkg x day) |
0.000125 to 5.0 |
0.00125 to 5.0 |
|
resolution |
cc/(pkg x day) |
0.00001 |
0.0001 |
reproducibility |
cc/(pkg x day) |
0.00001 or ± 2%* |
0.0001 or ± 2%* |
*The reading in the environment/Celsius, whichever is higher
Ox Tran 2/48 series |
unit |
Test temperature range |
environment |
Controlled relative humidity testing range |
environment |
Controlled relative humidity carrier gas range (regulating and detecting chamber) |
0-30% to 90% ± 5% |
Physical specifications
16.25 inches high x 32.25 inches wide x 22.25 inches deep (41.3 cm x 82.1 cm x 56.6 cm)
110 pounds (50 kg)
Electrical requirements
Voltage: 100-240 VAC 50/60 Hz
Maximum power consumption: 700 VA
temperature |
operation |
21 °C ± 2°C |
storage |
10 ° C to 30 ° C |
|
humidity |
operation |
10% to 60% RH (non condensing) |
storage |
5% to 85% RH (non condensing) |
carrier gas |
gas composition |
Nitrogen/hydrogen mixture (98%/2%) |
Rated gas supply pressure |
25 PSI, (1.72 bar), (172 kPa) |
Remote access and control (requires optional Perm Net Light software)
Standard Ethernet port (100T)
Dual USB 2.0 ports (for connecting keyboards, mice, or storage devices)
This product has passed UL and CSA certification, uses the ETL mark of Intertek Group plc., and has been certified to comply with CE standards.
Meets the following international safety standards.
IEC 61010-1:2010 Third Edition
UL 61010-1:2012 Third Edition
CAN/CSA-C22.2 No. 61010-1:2012 Third Edition
Complies with the following international EMC standards.
EN 61326-1:2013
EN 61000-3-2:2006、A1:2009、A2:2009
EN 61000-3-3:2013
Compliant with the EU RoHS Directive 2011/65/EU.
accessories
80 cm2 packaging test chamber
Large vertical tray testing cabin
Soft packaging bag testing cabin
50 cm2 thin film testing chamber
Packaging adapter test chamber
Coffee capsule testing chamber, 10 or 1 cup
Capture capacity testing chamber
Customized testing cabin
Certification film
Disposable packaging installation aluminum foil board
21 CFR Part 11 User and Data Security
PC Remote Viewing Software - PermNet Lite
PermWare Data Collection, Data Management, and Instrument Status Dashboard
Basic Preventive Maintenance Plan
Advanced Preventive Maintenance Plan
application
packaging film
single layer
multi-layer
Coating film
Coated paper/cardboard
packaging
Ordinary food packaging
Medical packaging
Bottle/Cap
Test Standard
ASTM D3985
ASTM F2622
ASTM F1307
ASTM F1927
ISO CD 15105-2
JIS K-7126-B
DIN 53380-3
GB/T 19789-2005
GB/T 31354-2014
According to ASTM D3985
Install the test sample as a semi barrier material between two chambers under ambient atmospheric pressure. One chamber is slowly purged with nitrogen gas flow, while the other chamber contains oxygen. When oxygen permeates through the membrane into the nitrogen carrier gas, it will be transported to the coulomb detector, where a current is generated that is proportional to the amount of oxygen entering the detector per unit time.